Facilidade de uso


CAUTION: Failure to fit the filter will invalidate the guarantee. A clogging up in the nozzle causes a pump pressure which is too high. This is why cleaning is required immediately. 1. Stop the machine and disconnect the nozzle. 2. Clean the nozzle. IMPORTANT: The cleaning tool (11) should only be used when the nozzle is detached! 3. Flush the nozzle backwards with water. pass freely through the machine vents. couplings should be greased regularly. 72 Original Instructions Poseidon 2 EN 8 Trouble-shooting Please ensure that you check the following before contacting the Nilfisk-ALTO service organization: Symptom Cause Recommended action Machine refuses to start Machine not plugged in Defective socket Fuse has blown Defective extension cable Plug in machine. Try another socket. Replace fuse. Switch off other machines. Try without the extension cable. Fluctuating pressure Pump sucking air Valves dirty, worn out or stuck Check that hoses and connections are air- tight. Clean and replace or refer to local Nilfisk- ALTO distributor Pump seals worn out Clean and replace or refer to local Nilfisk- ALTO distributor. Motor busses Low voltage or low temperature Activate the trigger of the spray handle. Machine stops Fuse has blown Incorrect mains voltage Thermal sensor activated Replace fuse. Switch off other machines. Check that the mains voltage corresponds to specification on the model tag. Leave the washer for 5 minutes to cool down. Nozzle partially blocked Clean the nozzle (see section 7.2) Fuse blows Fuse too small Change to an installation higher than the amp. consumption of the machine. You may try without the extension cable. Machine pulsating Air in inlet hose/pump Inadequate supply of mains water Nozzle partially blocked Water filter blocked Hose kinked Allow machine to run with open trigger until regular working pressure resumes. Check that the water supply corresponds to specifications required (see model tag) NB! Avoid using long, thin hoses (min. 1/2") Clean the nozzle (see section 7.2) Clean the filter (see section 7.1) Straighten out hose. Machine often starts and stops by itself Pump/spray handle is leaking Contact your nearest Nilfisk-ALTO Service Centre. Machine starts, but no water comes out Pump/hoses or accessory frozen Wait for pump/hoses or accessory to thaw. No water supply Water filter blocked Nozzle blocked Connect inlet water. Clean the filter (see section 7.1) Clean the nozzle (see section 7.2) Pump pressure drops Button for regulation of pressure / water volume not correctly adjusted Adjust the button to correct working pressure. In case problems other than the above occur, please contact your local Nilfisk-ALTO distributor. UK: Customer Services at Penrith - 01768 868995 Original Instructions 73 ENEN Poseidon 2 9 Further information 9.1 Recycling the washer 9.2 Warranty conditions Make the old cleaner unusable tive 2002/96/EC on old electriimmediately. cal and electronic appliances, used electrical goods must 1. Unplug the cleaner and cut be collected separately and the electric cable. recycled ecologically. Do not discard electrical appli-Contact your local authorities or ances with household waste. your nearest dealer for further information. As specified in European DirecNilfisk- ALTO guarantees this Repairs under this guarantee high pressure washer for 1 year. include replacement of defec- If your high pressure washer tive parts, exclusive of packing or ac ces so ries are handed in and postage/carriage. Besides, for repair, a copy of the receipt we refer to your national law of must be enclosed. sale. Guarantee repairs are being made on the following con di-The machine should be fort ions: warded to one of the service • that defects are attributable centres of the Nilfi sk-ALTO to flaws or defects in materiorganisation with description/ als or workmanship. (wear spe ci fi ca ti on of the fault. and tear as well as misuse are not covered by the gu a r-Repairs not covered by the an tee). guarantee conditions will be • that the directions of this invoiced. (I.e. malfunctions due instruction manual have been to Causes men ti o ned in section thoroughly observed. Troubleshooting Chart of the • that repair has not been car-instruction manual). ried out or attempted by other than Nilfi sk-trained service staff. • that only original accessories have been applied. • that the product has not been exposed to abuse such as knocks, bumps or frost. • that only water without any impurities has been used. • that the high pressure washer has not been used for rental nor used com mer cial ly in any other way. 74 Original Instructions Poseidon 2 10 Main Technical Data EN Type Rated pressure Poseidon 2-20 Poseidon 2-22 XT Poseidon 2-25 XT Poseidon 2-29 Poseidon 2-29 XT bar/MPa 69/6.9 120/12 140/14 150/15 150/15 Permissible pressure bar/MPa 76/7.6 130/13 150/15 160/16 160/16 Water flow, low pressure l/min 2.4 8.7 10.2 10 10 Water flow, high pressure l/min. 2.1 7.8 9 9.5 9.5 Rated input kW 1.7 2.3 2.9 3...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias