Facilidade de uso


. . . . . . . . . . . . . .6 Flush Before Using Equipment . . . . . . . . . . . . . .6 Integrated Air Control Module . . . . . . . . . . . . . . .6 Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 PressureRelief Procedure . . . . . . . . . . . . . . . . .9 Cleaning Solutions . . . . . . . . . . . . . . . . . . . . . . .9 Flushing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Startingthe Pump . . . . . . . . . . . . . . . . . . . . . . . 10 Adjusting the Pump . . . . . . . . . . . . . . . . . . . . . . 10 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Disconnect the Displacement Pump . . . . . . . . . 13 Reconnect the Displacement Pump . . . . . . . . . 13 Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 247549 Cart Mount Package . . . . . . . . . . . . . . 14 247550 Wall Mount Package . . . . . . . . . . . . . . 15 247551, 247553, and 258664 Cart Mount Packages . . . . . . . . . . . . . . . . . 16 247552, 247554, and 258665 Wall Mount Packages . . . . . . . . . . . . . . . . . 17 Parts Listings . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Wall Mounting Bracket Diagram. . . . . . . . . . . . . . 20 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Pump Performance Charts . . . . . . . . . . . . . . . . . . 22 Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 24 Graco Information . . . . . . . . . . . . . . . . . . . . . . . . 24 312585E Models Models Check your package’s identification plate (ID) for the 6-digit part number of your package. To order replacement parts, see Parts starting on page 14. All packages include integrated air controls, hose and gun, and ground wire. ID TI11530A Part No. Maximum Working Pressure psi (MPa, bar) Maximum Air Input Pressure psi (MPa, bar) Ratio Displacement Pump Size (cc per cycle) Includes: Portable Cart Wall Mount 247549 1250 (8.6, 86.2) 100 (0.7, 7.0) 12:1 550 cc . 247550 1250 (8.6, 86.2) 100 (0.7, 7.0) 12:1 550 cc . 247551 2275 (15.7, 156.9) 100 (0.7, 7.0) 23:1 580 cc . 247552 2275 (15.7, 156.9) 100 (0.7, 7.0) 23:1 580 cc . 247553 3065 (21.1, 211.3) 100 (0.7, 7.0) 30:1 430 cc . 247554 3065 (21.1, 211.3) 100 (0.7, 7.0) 30:1 430 cc . 258664 4000 (31.0, 310.3) 100 (0.7, 7.0) 45:1 290 cc . 258665 4000 (31.0, 310.3) 100 (0.7, 7.0) 45:1 290 cc . Related Manuals Manual Description 312745 247599 Displacement Pump 311825 Dura-Flo Displacement Pump; 1800 and 2400 311827 Dura-Flo Displacement Pump; 600, 750, 900, and 1200 311238 NXT Air Motor 311239 NXT Integrated Air Control Module 308511 Hydra-Clean Spray Gun 312585E Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable. WARNING FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion: • Use equipment only in well ventilated area. • Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc). • Keep work area free of debris, including solvent, rags and gasoline. • Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present. • Ground all equipment in the work area. See Grounding instructions. • Use only grounded hoses. • Hold gun firmly to side of grounded pail when triggering into pail. • If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem. • Keep a working fire extinguisher in the work area. EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals. • Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid a...

Este manual também é adequado para os modelos :
Equipamento de lavagem - Hydra-Clean 247550 (971.54 kb)
Equipamento de lavagem - Hydra-Clean 247549 (971.54 kb)
Equipamento de lavagem - Hydra-Clean 247552 (971.54 kb)
Equipamento de lavagem - Hydra-Clean 247553 (971.54 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias