|
por este dispositivo também tem outras instruções :
Facilidade de uso
Open Source Notice You can view details of the Open Source components used on the Client. Open source license notice In the case of using open source software, Open Source licenses are available on the product menu. Open Source License Notice is written only English. Shutdown You can log off, close, or restart the Client. 633 Using the "Zero Client" (TB-CH) 3 3 Using the "Zero Client" (TB-CH) 1 Log-off from account “***” Log off from the Client if you are logged on. This option is enabled only when you are logged on to the Client. To log off, select Yes in the Notice window. 2 Shutdown the system You can close the Client. To close the Client, select Yes in the Notice window. 3 Restart the system You can restart the Client. To restart the Client, select Yes in the Notice window. 643 Using the "Zero Client" (TB-CH) 3 3 Using the "Zero Client" (TB-CH) Remote Desktop You can view a list of desktops and applications (on the Citrix Server) the Client can connect to when logged on. 653 Using the "Zero Client" (TB-CH) 3 3 Using the "Zero Client" (TB-CH) Desktop List 1 Connect You can connect to a desktop or application on the list by clicking the corresponding Connect button or double-clicking the desktop or application desired. When a connection to a desktop or application is established, the Connect button for the desktop or application will be replaced by the Disconnect button in the Desktop List. The corresponding desktop or application row in the list will be highlighted as shown below. You can connect to more than one desktop or application. The names of the desktops and applications connected will be highlighted. 2 Disconnect The Disconnect button disconnects the corresponding desktop or application connected. When the desktop or application is disconnected, a list of connected desktops or applications will appear if there are any. 3 Refresh To update the Desktop List that contains a list of desktops or applications on the Citrix Server, click Refresh. 663 Using the "Zero Client" (TB-CH) 3 3 Using the "Zero Client" (TB-CH) 4 Reconnect You can display desktops and applications that are not displayed even though they are connected to the Client. Double-click the desktop or application desired. The corresponding desktop or application row in the list will be highlighted. Double-click Memo. A notepad window will be displayed. Status Icon Network icon: Display the current network status using an icon. 1 Not connected to the network. 2 Attempting to connect to the network. 3 Connected to the network. 673 Using the "Zero Client" (TB-CH) 3 3 Using the "Zero Client" (TB-CH) Terminal Lock This menu locks the Network and Terminal Properties options so that their settings cannot be changed. The corresponding shortcut key is [CTRL + ALT + F6]. • How to lock the two options Press and hold the shortcut key for a specified time (about 8 seconds). When the lock is on, the options locked will be indicated on the toolbar as shown below. • How to unlock the two options Press and hold the shortcut key for a specified time (about 8 seconds). Note that you are prompted to enter the password in order to unlock the two options. 683 Using the "Zero Client" (TB-CH) 4 4 Troubleshooting Guide 4.1 Requirements Before Contacting Samsung Customer Service Center 4.1.1 Check the following. Sound issue There is no sound. Check the connection of the audio cable or adjust the volume. Check the volume. The volume is too low. Adjust the volume. If the volume is still low after turning it up to the maximum level, adjust the volume in the audio settings program. 694 Troubleshooting Guide 5 5 Specifications 5.1 General Model Name TB-WH TB-CH Power Supply This product uses 100 to 240V. Refer to the label at the back of the product as the standard voltage can vary in different countries. Monitor connectors RGB OUT (D-Sub) port, DVI OUT port Server connector LAN Speaker 1 W x 2 USB USB 2.0 x 6 (Down stream) Dimensions (W x H x D) / Weight 244.0 X 340.0 X 227.0 mm / 9.6 X 13.4 X 8.9 inches / 2.3 kg / 5.1 lb Environmental considerations Operating Temperature : 50.F ~ 122.F (10.C ~ 50.C) Humidity : 10 % – 90 %, non-condensing Storage Temperature : -4.F ~ 113.F (-20.C ~ 45.C) Humidity : 5 % – 90 %, non-condensing VESA (V x H) 75 x 75 mm / 100 x 100 mm The above specifications are subject to change without notice to improve quality. This device is a Class B digital apparatus. (USA only) Dispose unwanted electronics through an approved recycler. To find the nearest recycling location, go to our website: or call, (877) 278 - 0799 CALIFORNIA USA ONLY (Applicable for networking models only.) This Perchlorate warning applies only to primary CR(Manganese Dioxide) Lithium coin cells in the product sold or distributed ONLY in California USA "Perchloate Material - special handling may apply, See perchlorate." 705 Specifications 5 5 Specifications 5.2 Power consumption PowerSaver Normal operation mode St...
Este manual também é adequado para os modelos :Monitores - TB-CH (3.31 mb)