Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação Medion, Modelo MEDION AKOYA E54001 (MD 20086) EU - MSN: 30010448

Fabricante : Medion
Arquivo Tamanho: 3.11 mb
Arquivo Nome :
Língua de Ensino: itenesfrdenlda
Ir para baixar



Facilidade de uso


. Take regular breaks when working at your TFT monitor, to prevent tension and tiredness. DE EN FR ES IT NL DK 3 Safety information Repair . Leave the repair of your TFT monitor exclusively to qualified specialist personnel. . Please contact our authorised Service Partners exclusively in the case of a necessary repair. Intended environment . The TFT monitor can be operated at a surrounding temperature from 0° C to +40° C and at a relative ambient moisture level of < 80% (non-condensing). . The TFT monitor can be stored at -20° C to +60° C when it has been turned off. . Wait to bring the device into operation until it has reached the surrounding temperature, after the TFT monitor has been transported. Moisture, which can cause an electrical short-circuit, can form within the TFT monitor in the case of wide variations in temperature or moisture. Power supply Please pay attention: Parts of the device will be subject to voltage, even if the mains switch has been switched off. Pull the mains plug from the socket, to interrupt the power supply to your TFT monitor or to release the device from voltage completely. . Only operate the TFT monitor at an earthed socket with 100-240V~, 50/60 Hz. Ask your energy supplier if you are not sure about the power supply at the set-up location. . We recommend the use of protection against excess voltage for additional safety, in order to protect your TFT monitor against damage because of voltage peaks or electrical flashes on the mains network. . Pull the mains plug from the socket, in order to interrupt the power supply to your monitor. . The socket must be located close to the TFT monitor and be easily accessible. . Lay the cable so that no-one can tread on it or trip over it. . Do not place any objects on the cable, because it could be damaged otherwise. . Please pay attention to the fact that the standby switch does not separate the device completely from mains electricity. The device will consume electricity in standy operation apart from this. Pull the mains plug out of the mains socket to separate the device from the network completely. English Norms / Electromagnetic compatibility The TFT monitor fulfils the requirements for electromagnetic compatibility and electrical safety of the following regulations: EN 55022:2006 Information technology equipment, interference – Limiting values and measuring procedure EN 55024:1998 + Information technology equipment – Characteristics resisting interference -Limiting A1:2001 + values and test procedure A2:2003 EN 61000-3-2:2006 Electromagnetic compatibility (EMV); Part 3: Limiting values; Section 2: Limiting values for harmonic currents (device input current < 16A per conductor) EN 61000-3-3:1995 + Electromagnetic compatibility (EMV); Part 3: Limiting values; Section 3: Limiting values A1:2001 + for variations in voltage and flickerin in low voltage networks for devices with and A2:2005 input current < 16A per conductor EN 60950-1:2001 + Safety of information technology equipment A11:2004 . The Guidelines for electromagnetic compatibility (EMV) must be observed at the connection. . Maintain at least one metre clearance from high frequency and magnetic sources of interference (television device, loudspeakers, mobile phone, cell phone, etc.), in order to avoid disruptions to function and data loss. . The failure of individual or several scanning spots can arise in rare cases, in spite of the most modern manufacture, because of the highly complex technology. Your device complies with the European Norm ISO 13406-2 Class II (Pixel error class) (see P. 16). Your device complies with the basic requirements and the relevant guidelines of the 2004/108/EU EMV Guidelines [electromagnetic compatibility] and the 2006/95/EU Guideline for low voltage devices. DE EN FR ES IT NL DK 5 Safety information Bringing the device into operation Information Please read the “Safety information” chapter on page 3 under all circumstances before bringing the device into operation. Setup Attach the stand of the TFT monitor as illustrated. Carry out this step before connecting the monitor. (Ill.: Installation of the monitor stand) Preparation of your PC You will possibly have to make some preparations if you have operated a CRT monitor with your computer in the past. This will be necessary if your current monitor is operated with settings that are not supported by your new TFT monitor. Supported monitor settings This TFT monitor supports the following modes. Resolution Horizontal Frequency Vertical Frequency 720 x 400 31.47 kHz 70 Hz 640 x 480 31.47 kHz 60 Hz 640 x 480 31.47 kHz 67 Hz 640 x 480 37.5 kHz 75 Hz 800 x 600 37.7 kHz 56 Hz 800 x 600 37.8 kHz 60 Hz 800 x 600 48.0 kHz 72 Hz 800 x 600 46.87 kHz 75 Hz 832 x 624 48.67 kHz 75 Hz 1024 x 768 48.36 kHz 60 Hz 1024 x 768 56.48 kHz 70 Hz 1024 x 768 60.0 kHz 75 Hz 1152 x 864 67.0 kHz 75 Hz 1280 x 768 47.0 kHz 60 Hz 1280 x 960 60.0 kHz 60 Hz 1280 x 1024 63.98 kHz 60 Hz 1280 x 1024 80.0 kHz 75 Hz 1440 x 900 56.0 kHz 60...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias