Log:
Assessments - 2, GPA: 4.5 ( )

Instruções de Operação Crown, Modelo POWER BASE 3

Fabricante : Crown
Arquivo Tamanho: 238.78 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Stereo/Mono: A three-position back panel switch used to select Stereo, Bridge-Mono or Parallel-Mono mode. Sensitivity: A three-position switch inside the back cover plate used to select the input sensitivity for both channels: 0.775 volts or 1.4 volts for standard 1 kHz power, or 26 dB voltage gain (see Section 2.3). Input Ground Lift: A two-position back panel switch used to isolate the phone jack and chassis grounds. Reset (Power Base-3only): A back panel push button used to reset the circuit breaker that protects the power supplies. Indicators Power: This amber indicator shows the on/off status of the low voltage power supply. Input/Output Input Connector: Balanced . inch phone jacks. See Section 5 for XLR and barrier block accessories. Input Impedance: Nominally 20 K ohms, balanced; 10 K ohms, unbalanced. Output Connector:Two sets of color-coded 5-way bbinding posts (for banana plugs, spade lugs or bare wire). Output Impedance: Less than 10 milliohms in series with less than 2 microhenries. DC Output Offset: Less than 10 millivolts. Output Signal Stereo: Unbalanced, two-channel. Bridge-Mono: Balanced, single-channel. Channel 1 controls are active; Channel 2 controls should be turned down and not used. Parallel-Mono: Unbalanced, single-channel. Channel 1 controls are active; Channel 2 controls should be turned down and not used. Protection Power Baseamplifiers are protected against shorted, open or mismatched loads; overloaded power supplies; excessive temperature, chain destruction phenomena, input overload and high-frequency blowups. They also protect loudspeakers from input and output DC, as well as providing protection from turn-on/turn-off transients. If operating conditions are unreasonable, the patented ODEPcircuitry proportionally limits the drive level to protect the output transistors, particularly in the case of elevated temperature. A thermal switch imbedded in the transformer protects the power supplies from overload. In the rare event that a transformer overheats, the thermal switch removes power, waits until the unit has cooled to a safe temperature and then resets itself. Turn On: Four second delay with no dangerous transients. Contact us if you need to change the delay. Construction Durable black finish on steel chassis with special “flowthrough” ventilation from front to side panels. Cooling: Internal heat sinks with forced-air cooling for rapid, uniform heat dissipation. Dimensions: Standard 19-inch (48.3 cm) rack mount width (EIA RS-310-B), 3.5-inch (8.9 cm) height and 16-inch (40.6 cm) depth behind the mounting surface. Approximate Weight: Center of gravity is 6 inches (15.2 cm) behind front mounting surface. 120 VAC, 60 Hz Units: Power Base-1: 30 pounds (13.6 kg) net; 34 pounds (15.4 kg) shipping weight. Power Base-2: 34 pounds (15.4 kg) net; 38 pounds (17.2 kg) shipping weight. Power Base-3: 36 pounds (16.3 kg) net; 40 pounds (18.2 kg) shipping weight. Page 14 Power Base Series Power Amplifiers Crown specifications are guaranteed for three years. In an effort to provide you with as much information as possible about the high power-producing capabilities of your amplifier, we have created the following power matrices. Minimum Power Specifications Crown’s minimum power specifications represent the absolute smallest amount of output power you can expect from your amplifier when it is driven to full output under the given conditions. Some spaces in each matrix may be left blank because the same guarantee is not provided for those conditions—however, your amplifier will perform well under all conditions listed in each matrix. When measuring power, 0.1% THD appears to be the industry standard for distortion. Two of the maximum average power specifications shown in each minimum power matrix are measured at 0.1% THD so you can easily compare Crown specifications to those of other manufacturers. But this high level of distortion actually allows for some clipping which is undesirable. Because of this, a maximum average power spec at 0.05% THD is included in each minimum power matrix which represents non-clipped conditions. Although most manufacturers do not give you power specifications at 0.05% THD, we encourage them to provide these specifications so you will have a more realistic representation of the way amplifiers should be used in the real world—without a clipped output signal. Many manufacturers publish power specs with a tolerance of ±1 dB or worse. This means their amplifier can deviate more than 20% in output! A 100 watt amplifier would meet their specification if it only produced 79.4 watts. Other manufacturers qualify their specs by saying they are “typical,” “subject to manufacturing tolerances,” “single channel driven” or that they are specified with “fuses bypassed.” Each of these statements effectively removes any performance guarantee. In fact, some manufacturers use these tactics to generate large power numbers, and they don’t even print a disclaimer. We take a different ap...

Este manual também é adequado para os modelos :
Instrumentos musicais - POWER BASE 2 (238.78 kb)
Instrumentos musicais - POWER BASE 1 (238.78 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias