Log:
Assessments - 1, GPA: 5 ( )

Instruções de Operação GE, Modelo Triplex DVMRe 4eZT

Fabricante : GE
Arquivo Tamanho: 1.68 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Choose from 1 to 99 days or Off. The default setting is Off. ADM will change. Are you sure? Message ADM Setting 99 Days Yes 3.10 Alarms Use this menu to configure the alarm handling features of the unit. Caution! The DVMRe Triplex eZ’s primary function is to furnish video multiplexing and recording with a multiscreen display. Although the unit has alarm handling and motion detection functions, these are considered secondary features. This unit should not be the only alarm device on site. q• Main Menu ® Alarms ® Input Configuration Configure the alarm inputs as either Normally Open or Normally Closed. Configure inputs as follows. Normally Open Zero Potential Relay Contact: Configure in menu as Normally Open. Normally Closed Zero Potential Relay Contact: Configure in menu as Normally Closed TTL Active High: Configure in menu as Normally Closed. TTL Active Low: Configure in menu as Normally Open. Open Collector Active On: Configure in menu as Normally Open. Open Collector Active Off: Configure in menu as Normally Closed. q• Main Menu ® Alarms ® Alarm Latch This feature determines how the unit latches alarm conditions. Selecting from the following options. Latched: The alarm is activated until it is silenced and acknowledged by the user. Latched Transparent Timed Out Input Configuration Alarm Latch Enable / Disable Alarm History Link to a Macro Buzzer Setup Notification Archive Alarms 0150-0198H 37 DVMRe Triplex eZ Transparent: The alarm is active only while receiving alarm input. The alarm condition is canceled when the alarm input ceases. Timed Out: The alarm condition is latched for the amount of time selected in this menu, then it is automatically silenced and acknowledged. If the alarm input exceeds the duration specified in this menu, the unit silences and acknowledges the alarm when the alarm input ceases. Select the timeout duration, the range is from 1 to 250 seconds. Transparent alarms cannot be silenced and acknowledged. If transparent mode is preferred, but the ability to silence and acknowledge alarms is desired, select Timed Out and set the Alarm Timeout to two seconds. q• Main Menu ® Alarms ® Enable / Disable Use this menu to Enable or Disable the alarm inputs. Select from the following: • Individual Enable: Allow the user to access the Alarm Enable submenu, and enable or disable alarm inputs on a per camera basis. • Enable All • Disable All Rotate the Jog to navigate, and the Shuttle to change the values. Save changes and exit the menu: Select [OK], then press the Enter button. Exit the menu without making changes: Press the Menu button, or select [CANCEL], then press the Enter button. Enable All Disable All Individual Enable q• Main Menu ® Alarms ® Alarm History Use this window to view a list of the 100 most recent alarms. Alarms are displayed 10 at a time. Rotate the Jog to scroll through the alarms. Information displayed in this window is: • The alarms number in the list. • The date of the alarm (month and day). • The time of the alarm (hours, minutes, and seconds). The number of the camera input in alarm. Alarm History Box 001- 02/04 18:40:32 16 002- 02/15 12:00:10 11 003- 02/28 10:10:20 08 : : 010- 03/15 05:12:16 04 [OK] 0150-0198H 38 DVMRe Triplex eZ q• Main Menu ® Alarms ® Link To A Macro Use this menu to link an alarm input to a macro. If a link is created, a macro will run each time that alarm is activated. Alarm: Select the alarm input you would like to link. Macro: Select the macro number you wish to link to. Leave this setting blank if you do not wish to link to a macro. Rotate the Jog to navigate, and the Shuttle to change the values. Save changes and exit the menu: Select [OK], then press the Enter button. Exit the menu without making changes: Press the Menu button, or select [CANCEL], then press the Enter button. q• Main Menu ® Alarms ® Buzzer Setup Use this menu to configure the internal buzzer. Global Buzzer: The Global Buzzer setting acts as a master On/Off switch. Setting the Global Buzzer to OFF deactivates all buzzer activity. q• Main Menu ® Alarms ® Notification Use this menu to select Email Alarm Notification. Buzzer Setup [CANCEL] [OK] Global Buzzer : ON Email Email Notification Setup This screen allows the user to setup the types of events to be notified of, and the email addresses (up to two) to be notified. Follow the context sensitive on-screen instructions to setup the individual fields. Also, please note that the Region/Time Zone setting must be set correctly for Email notification to time stamp messages accurately. If the Notify Alarm or Notify Record fields are enabled you will notified of the results of the Hard Disk Test. 0150-0198H 39 DVMRe Triplex eZ One or more of these fields must be set to ENABLE to receive an email notification of the selected event. Notify Vidloss: Notify Record: Notify Menu Access: Notify Connection: Email User 1: Email Domain 1: Email User 2: Email Domain 2: Local User: Local Domain: SMTP Server: Notify Alarm: Notify Archive: Notify Pow...

Este manual também é adequado para os modelos :
Instrumentos musicais - Triplex DVMRe 16eZT (1.68 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias