Log:
Assessments - 3, GPA: 4.3 ( )

Instruções de Operação Kustom, Modelo V15

Fabricante : Kustom
Arquivo Tamanho: 2.22 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


To turn your amplifier on, press switch upward. To turn amp off, press switch downward. Note: After the power switch is turned on, the tubes must warm up for approximately one minute before you will hear sound from your amplifier. V15 & 15H Back Panel 1 2 3 4 5 1. AC POWER CORD RECEPTACLE: Insert the AC cord (provided) firmly into the AC connector. NOTE: Replace the AC power cord if protective jacket is damaged or ground pin is damaged or removed. The fuse is located in a housing just below the receptacle. Replace only with same type and size. To remove the fuse, remove AC power cord and pull out on the tab above the fuse symbol located on the fuse carriage. Place the new fuse in the carriage clip and re-insert. NOTE: To prevent an electrical hazard, DO NOT replace fuse without using the fuse carriage. Replace the fuse carriage if lost or damaged before re-inserting the AC power cord. 2. FUSE: The fuse is located in a fuse tray just below the receptacle. Replace only with the same type and size. For your convenience, a spare fuse is located inside the fuse tray toward the front. To replace fuse, remove AC power cord. Remove fuse tray by pulling the tab located above the fuse symbol away from the receptacle. 3: SPEAKER OUTPUTS: These 1/4” jacks are provided to connect the internal and/or external speakers to the V15. THE AMPLIFIER SHOULD NEVER BE OPERATED WITHOUT A SPEAKER PLUGGED INTO A SPEAKER JACK. 4. DIRECT OUT: The XLR Direct Out jack is designed to connect the amplifier to a recording or live mixer. The output is speaker- emulated, and mimics the sound of the Celestion loudspeaker. This output is very useful for direct recording, and especially helpful for live applications since it eliminates a live microphone on stage and the resulting feedback potential. 5. GROUND LIFT: The Ground Lift switch disconnects pin 1 of the XLR Direct Out jack to eliminate a “ground loop” hum. A ground loop can exist when the amp and the mixer it is plugged into are connected to grounded outlets that are in physically different locations and/ or on different circuits, and should only be used if there is an audible hum. Pressing the ground lift does not disconnect the ground connection from the chassis. DI RECT OUT INPUT 1/2 - 12AX7 Signal VOL UME OUTPUTTRANSFORMER 16 OHMS8 OHMS4 OHMS 1/2 - 12AX7 2 X EL84 Conditioning SignalConditioningTONE 8 OHMS 8 INCH SPEAKER INTERNAL BASS CONTROL AMERICANBRITISH SPEAKER CABSIMULATION 213 GND LIFT (+) (- ) DI RECT OUT INPUT 1/2 - 12AX7 Signal VOL UME OUTPUTTRANSFORMER 16 OHMS4 OHMS 1/2 - 12AX7 2 X EL84 Conditioning SignalConditioningTONE BASS CONTROL AMERICANBRITISH SPEAKER CABSIMULATION 213 GND L IFT (+) (- ) V15 Signal Flow Diagram 15H Signal Flow Diagram V15 Specifications Output Power 4 / 15 Watts . inch jacks w/ impedance selector for 4 Ohm, 8 Ohm and 16 Ohm speakers Internal Speaker 8 Ohms Speaker 1 10” Celestion Gain 70dB @ 1 kHz Preamp Tube 1 12AX7 Poweramp Tubes 2 EL84 Power Requirements USA / Canada 120VAC/60Hz 80W Europe 230VAC/50Hz 80W UK 230VAC/50Hz 80W Australia 240VAC/50Hz 80W Japan 100VAC/50-60Hz 80W Dimensions / Weight cm/Kilogram 40.2H x 41.8W x 21.5D 11.8 kgInches/Pounds 15.8 H x 16.5 W 8.5 D 26 Lbs. 15H SpecificationsOutput Power 4 / 15 Watts . inch jacks w/ impedance selector for 4 Ohm, 8 Ohm and 16 Ohm speakers Internal Speaker 8 Ohms Gain 70dB @ 1 kHz Preamp Tube 1 12AX7 Poweramp Tubes 2 EL84 Power Requirements USA / Canada 120VAC/60Hz 80W Europe 230VAC/50Hz 80W UK 230VAC/50Hz 80W Australia 240VAC/50Hz 80W Japan 100VAC/50-60Hz 80W Dimensions / Weight cm/Kilogram 14 H x 36.7 W x 22.5 D 4.8 kg Inches/Pounds 5.5 H x 14.4 W x 8.9 D 10.58 Lbs. EC Declaration of Conformity We: Kustom Musical Amplification INC. 3015 Kustom Drive Hebron, Ky 41048-0568 Tel: 1-859-817-7100 Fax: 1-859-817-7150 Declare that the product Product name: Kustom Product model number: DEFENDER V15 & DEFENDER 15H to which this declaration relates is in conformity with the following standards; EN55013: 2001/+A1: 2003+A2: 2006 Limits and methods of measurement of radio disturbance characteristics of broadcast receivers and associated equipment. EN55020: 2007 Electromagnetic immunity of broadcast receivers and associated equipment. EN61000-3-2: 2006 Limits for harmonic current emissions (equipment input current < 16A per phase). EN61000-3-3: 2008 Limitation of voltage fluctuations and flicker in low voltage supply systems for equipment with rated currents < 16A. EN60065: 2002+A1: 2006+A11: 2008 Safety requirements for main operated electronic and related apparatus for household and similar general use. Following the provisions of EU Council Directive(s): 72/73 EEC and 89/336/EEC. We the undersigned, hereby declare that the equipment specified above conforms to the aforementioned directive(s). Name of authorized person: James Brown, Chief Engineer Signature:______________________ Date: March 15, 2011 Kustom Musical Amplification INC. 3015 Kustom Drive Hebron, Ky 41048-0568 Tel: 1-859-817-7100 Fax: 1-859-8...

Este manual também é adequado para os modelos :
Instrumentos musicais - 15H (2.22 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias