Log:
Assessments - 1, GPA: 4 ( )

Instruções de Operação Roland, Modelo UA-100G

Fabricante : Roland
Arquivo Tamanho: 1.4 mb
Arquivo Nome :
Língua de Ensino: ende
Ir para baixar



Facilidade de uso


Receive Data ■ Channel Voice Messages • Note On Status 2nd byte 3rd byte 9nH kkH vvH n = MIDI channel number: 0H-FH (ch.1-ch.16) kk = note number : 00H-7FH (0-127) • Used for pitch changes when using VT effect • Pitch Bend Change Status 2nd byte 3rd byte EnH llH mmH n = MIDI channel number: 0H-FH (ch.1-ch.16) mm, ll = Pitch Bend value: 00 00H-40 00H-7F 7FH (-8192-0- +8191) • Used for pitch changes when using VT effect • Control Change You can control the main parameters for the UA-100's mixer using Control Change messages. Mixer parameters and setting ranges Parameter mm ll (setting range) MIC/LINE Selector 21 (15H) 0: Mic Mode, 1: Line Mode, 2: MIC1+MIC2 Mode Pan 10 (0AH) 0 (left) - 64 (center) - 127 (right) Send 1 16 (10H) 0 - 127: Full/Compact Effect mode only Send 2 17 (11H) 0 - 127: Full/Compact Effect mode only Mute 18 (12H) 0 (OFF), 1 (ON: Mute) Solo 19 (13H) 0 (OFF), 1 (ON: Solo) Sub Fader 20 (14H) 0 - 127 Main Fader 7 (07H) 0 - 127 Selector 22 (16H) 0: MIC1 (Mic Mode), LINE (Line Mode), MIC1+MIC2 (MIC1+MIC2 Mode), 1: MIC2 (Mic Mode only), 2: WAVE1, 3: WAVE2, 4 to 7: CH1 to 4, 8: SUB, 9: MAIN 0: MIC1 (Mic Mode), LINE (Line Mode), 1: MIC2 (Mic Mode only), 2: WAVE1, 3: WAVE2, 4: VT_OUT, 5: MAIN Effect Switch 23 (17H) 0 (OFF), 1 (ON: Apply effect) Correspondences Between Mixer Signals and Parameters * Note that the controller numbers used by the UA-100 differ from the Control Change messages defined in the MIDI standard, and are used to control proprietary parameters for the UA-100. Status 2nd byte 3rd byte BnH mmH llH n = MIDI channel number: 0H-FH (ch. 1 to ch. 16:Refer to the correspondence chart) mm = Mixer parameter number:Refer to the correspondence chart ll = Mixer parameter value: 00H - 7FH (0 - 127) Correspondences Between MIDI Channels and Mixer Signals MIDI channel Signal 1Ch. LINE (Line Mode), MIC1/GUITAR (Mic Mode), MIC1+MIC2 (MIC1+MIC2 Mode) 2Ch. MIC2 (Mic mode only) 3Ch. WAVE1 4Ch. WAVE2 5Ch. SysRET(system effect return Main bus) 6Ch. SysSUB(system effect return Sub bus) 15Ch. WAVE (Rec) 16Ch. LINE (Master) Parameter MIC1/LINE/ MIC1MIC2 1Ch. MIC2 2Ch. WAVE1 3Ch. WAVE2 4Ch. SysRET 5Ch. SysSUB6 Ch. WAVE 15Ch. LINE 16Ch. MIC/LINE Selector 21 (15H) O Pan 10 (0AH) 0 0 Send 1 16 (10H) 0 0 0 0 O 0 Send 2 17 (11H) 0 0 0 0 0 0 Mute 18 (12H) 0 0 0 0 Solo 19 (13H) 0 0 0 0 Sub Fader 20 (14H) 0 0 0 0 Main Fader 7 (07H) 0 0 0 0 O 0 Selector 22 (16H) 0 0 Effect Switch23 (17H) 0 0 0 0 0 0 Q Data Entry (Controller number 6, 38) Status 2nd byte 3rd byte BnH 06H mmH BnH 26H llH n = MIDI channel number: 0H-FH (ch.1-ch.16) mm, ll = the value of the parameter specified by RPN/NRPN mm = MSB(upper byte of parameter), ll = LSB(lower byte of parameter) 77 MIDI-Implementation O RPN MSB/LSB (Controller number 100, 101) System Exclusive Message Status BnH BnH 2nd byte 65H 64H 3rd byte mmH llH n = MIDI channel number: 0H-FH (ch.1-ch.16) mm = upper byte of parameter number specified by RPN (MSB) ll = lower byte of parameter number specified by RPN (LSB) * The value specified by RPN will not be reset even by messages such as Program Change or Reset All Controller. The RPN (Registered Parameter Number) messages are expanded Control Changes, and each function of an RPN is described by the MIDI Standard. To use these messages, you must first use RPN (Controller number 100 and 110, their order does not matter) to specify the parameter to be controlled, and then use Data Entry messages (Controller number 6, 38) to specify the value of the specified parameter. Once an RPN parameter has been specified, all Data Entry messages received on that channel will modify the value of that parameter. To prevent accidents, it is recommended that you set RPN Null (RPN number = 7FH/7FH) when you have finished setting the value of the desired parameter. The UA-100 receives the RPNs shown below. RPN Data entry 00H 00H mmH -- 00H 01H mmH llH 00H 02H mmH 7FH 7FH Explanation Pitch Bend Sensitivity mm: 00H-18H (0-24 semitones), Initial Value = 02H (2 semitones) ll: ignored (processed as 00H) specify up to 2 octaves in semitone steps. Master Fine Tuning mm, ll: 00 00H - 40 00H - 7F 7FH (-100 - 0 - +99.99 cents), Initial Value = 40 00H (0 cent) Master Coarse Tuning mm: 28H - 40H - 58H (-24 - 0 - +24 semitones), ll: ignored (processed as 00H) RPN null Set condition where RPN and NRPN are unspecified. The data entry messages after set RPN null will be ignored. (No Data entry messages are required after RPN null). Settings already made will not change. mm, ll: ignored ■ System Realtime Message • Active Sensing Status F0H F0H: ii = ID number: dd..... F7H: Data byte iiH, ddH........eeH Status F7H System Exclusive Message status an ID number (manufacturer ID) to indicate the manufacturer whose Exclusive message this is. Roland's manufacturer ID is 41H. ID numbers...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias