Log:
Assessments - 0, GPA: 5 ( )

Instruções de Operação Roland, Modelo VC-1_2

Fabricante : Roland
Arquivo Tamanho: 3.94 mb
Arquivo Nome :
Língua de Ensino: ende
Ir para baixar



Facilidade de uso


Data Transmission ¦Channel Voice Messages .Control Change .Bank Select (Controller number 0, 32) Status 2nd byte 3rd byte BnH 00H mmH BnH 20H llH n = MIDI channel number: 0H - FH (ch.1 - 16) mm, ll = Bank number: 00 00H - 7F 7FH (bank.1 - bank.16384) * Not transmitted when Bank Select Switch (SYSTEM MIDI) is OFF. * The Patches corresponding to each Bank Select are as follows. BANK SELECT MSB LSB PROGRAM NUMBER BATCH BANK PATCH NUMBER 087 000 001 - 064 Internal 1 11 -88 001 001 - 064 Internal 2 11 -88 002 001 - 064 Internal 3 11 -88 003 001 - 064 Internal 4 11 -88 004 001 - 064 Internal 5 11 -88 005 001 - 064 Internal 6 11 -88 006 001 - 064 Internal 7 11 -88 007 001 - 064 Internal 8 11 -88 008 001 - 064 Preset 1 11 -88 009 001 - 064 Preset 2 11 -88 010 001 - 064 Preset 3 11 -88 011 001 - 064 Preset 4 11 -88 012 001 - 064 Preset 5 11 -88 013 001 - 064 Preset 6 11 -88 * The transmitted value of MSB can be changed by Tx Bank Select (Patch MIDI). * In that case the transmitted value of LSB is always 0. .Portamento Switch (Controller number 65) Status 2nd byte 3rd byte BnH 41H vvH n = MIDI channel number: 0H - FH (ch.1 - 16) vv = Control value: 00H - 7FH (0 - 127) 0-63 = OFF, 64-127 = ON .Program Change Status 2nd byte CnH ppH n = MIDI channel number: 0H - FH (ch.1 - 16) pp = Program number: 00H - 3FH (prog.1 - prog.64) * Not transmitted when Program Change Switch (SYSTEM MIDI) is OFF. ¦System Realtime Messages .Active Sensing Status FEH * This message is transmitted at intervals of approximately 250 msec. .System Exclusive Messages Status F0H :System Exclusive F7H :EOX (End Of Exclusive) Transmitted in the following three cases. 1. When Operating Bulk-Dump 2. If Exclusive of System MIDI is “P-Dump,” this unit transmits all parameters in the patch when the patch is changed. 3. If Exclusive of System MIDI is “TxEdit,” this unit transmits the parameter when the parameter is edited. Refer to Section 3 to see details. 2. Receive data ¦Channel Voice Messages .Note off Status 2nd byte 3rd byte 8nH kkH vvH 9nH kkH 00H n = MIDI channel number: 0H - FH (ch.1 - 16) kk = note number: 00H - 7FH (0 - 127) vv = note off velocity: 00H - 7FH (0 - 127) .Note on Status 2nd byte 3rd byte 9nH kkH vvH n = MIDI channel number: 0H - FH (ch.1 - 16) kk = note number: 00H - 7FH (0 - 127) vv = note on velocity: 01H - 7FH (1 - 127) .Control Change m Bank Select (Controller number 0, 32) Status 2nd byte 3rd byte BnH 00H mmH BnH 20H llH n = MIDI channel number: 0H - FH (ch.1 - 16) mm, ll = Bank number: 00 00H - 7F 7FH (bank.1 - bank.16384) * Not received when the Bank Select Switch (SYSTEM MIDI) is OFF. * The Patches corresponding to each Bank Select are as follows. BANK SELECT MSB LSB PROGRAM NUMBER BATCH BANK PATCH NUMBER 087 000 001 - 064 Internal 1 11 -88 001 001 - 064 Internal 2 11 -88 002 001 - 064 Internal 3 11 -88 003 001 - 064 Internal 4 11 -88 004 001 - 064 Internal 5 11 -88 005 001 - 064 Internal 6 11 -88 006 001 - 064 Internal 7 11 -88 007 001 - 064 Internal 8 11 -88 008 001 - 064 Preset 1 11 -88 009 001 - 064 Preset 2 11 -88 010 001 - 064 Preset 3 11 -88 011 001 - 064 Preset 4 11 -88 012 001 - 064 Preset 5 11 -88 013 001 - 064 Preset 6 11 -88 * The MSB value to be transmitted can be set individually for * each patch using Tx Bank Select (PATCH MIDI). * In this case, “0” is always output for the LSB. .Modulation (Controller number 1) Status 2nd byte 3rd byte BnH 01H vvH n = MIDI channel number: 0H - FH (ch.1 - 16) vv = Modulation depth: 00H - 7FH (0 - 127) .Portamento Time (Controller number 5) Status 2nd byte 3rd byte BnH 05H vvH n = MIDI channel number: 0H - FH (ch.1 - 16) vv = Portamento Time: 00H - 7FH (0 - 127) .Data Entry (Controller number 6, 38) Status 2nd byte 3rd byte BnH 06H mmH BnH 26H llH n = MIDI channel number: 0H - FH (ch.1 - 16) mm, ll = the value of the parameter specified by RPN/NRPN mm = MSB, ll = LSB .Volume (Controller number 7) Status 2nd byte 3rd byte BnH 07H vvH n = MIDI channel number:0H - FH (ch.1 - 16) vv = Volume: 00H - 7FH (0 - 127) .Hold 1 (Controller number 64) Status 2nd byte 3rd byte BnH 40H vvH n = MIDI channel number: 0H - FH (ch.1 - 16) vv = Control value: 00H - 7FH (0 - 127) 0-63 = OFF, 64-127 = ON .Portamento Switch (Controller number 65) Status 2nd byte 3rd byte BnH 41H vvH n = MIDI channel number: 0H - FH (ch.1 - 16) vv = Control value: 00H - 7FH (0 - 127) 0 - 63 = OFF, 64 - 127 = ON .RPN MSB/LSB (Controller number 100, 101) Status 2nd byte 3rd byte BnH 65H mmH BnH 64H llH n = MIDI channel number: 0H - FH (ch.1 - 16) mm = upper byte (MSB) of parameter number specified by RPN ll = lower byte (LSB) of parameter number specified by RPN <<< RPN >>> Control Changes include RPN (Registered Parameter Numbers), which are extended. When using RPNs, first RPN (Controller numbers 100 and 101; they can be sent in any order) should be sent in order to select the parameter, then Data Entry (Controller numbers 6 and 38) should be sent to set the value. This device receives the following RPNs. RPN Data ent...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias