Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação Roland, Modelo FP-7

Fabricante : Roland
Arquivo Tamanho: 281.04 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


(Initial value is ON) 8nH kkH vvH * The resulting effect is determined by System Exclusive messages. With the initial 9nH kkH 00H settings, this is Pitch Modulation Depth. n = MIDI channel number: 0H-FH (ch.1-ch.16) kk = note number: 00H-7FH (0-127) .Portamento Time (Controller number 5) vv = note off velocity: 00H-7FH (0-127) Status 2nd bytes 3rd byte BnH 05H vvH * For Drum Parts, these messages are received when Rx.NOTE OFF = ON for each Instrument. n = MIDI channel number: 0H-FH (ch.1-ch.16) * The velocity values of Note Off messages are ignored. vv = Portamento Time: 00H-7FH (0-127), Initial value = 00H (0) * This adjusts the rate of pitch change when Portamento is ON or when using the .Note on Portamento Control. A value of 0 results in the fastest change. Status 2nd bytes 3rd byte 9nH kkH vvH .Data Entry (Controller number 6, 38) Status 2nd bytes 3rd byte n = MIDI channel number: 0H-FH (ch.1-ch.16) BnH 06H mmH kk = note number: 00H-7FH (0-127) BnH 26H llH vv = note on velocity: 01H-7FH (1-127) n = MIDI channel number: 0H-FH (ch.1-ch.16) * Not received when Rx.NOTE MESSAGE = OFF. (Initial value is ON) mm, ll = the value of the parameter specified by RPN/NRPN * For Drum Parts, not received when Rx.NOTE ON = OFF for each Instrument. mm = MSB, ll = LSB .Polyphonic Key Pressure .Volume (Controller number 7) Status 2nd bytes 3rd byte Status 2nd bytes 3rd byte AnH kkH vvH BnH 07H vvH n = MIDI channel number: 0H-FH (ch.1-ch.16) n = MIDI channel number: 0H-FH (ch.1-ch.16) kk = note number: 00H-7FH (0-127) vv = Volume: 00H-7FH (0-127), Initial Value = 64H (100) vv = key pressure: 00H-7FH (0-127) * Volume messages are used to adjust the volume balance of each Part. * Not received when Rx.POLY PRESSURE (PAf) = OFF. (Initial value is ON) * Not received when Rx.VOLUME = OFF. (Initial value is ON) * The resulting effect is determined by System Exclusive messages. With the initial settings, there will be no effect. .Pan (Controller number 10) Status 2nd bytes 3rd byte .Control Change BnH 0AH vvH * When Rx.CONTROL CHANGE = OFF, all control change messages except for Channel Mode messages will be ignored. n = MIDI channel number: 0H-FH (ch.1-ch.16) * The value specified by a Control Change message will not be reset even by a Program vv = pan: 00H-40H-7FH (Left-Center-Right), Change, etc. Initial Value = 40H (Center) .Bank Select (Controller number 0, 32) * For Rhythm Parts, this is a relative adjustment of each Instrument’s pan setting. Status 2nd bytes 3rd byte * Some Tones are not capable of being panned all the way to the left or right. BnH 00H mmH * Not received when Rx.PANPOT = OFF. (Initial value is ON) BnH 20H llH .Expression (Controller number 11) n = MIDI channel number: 0H-FH (ch.1-ch.16) Status 2nd bytes 3rd byte mm, ll = Bank number: 00H, 00H-7FH, 7FH (bank.1-bank.16384), BnH 0BH vvH Initial Value = 00 00H (bank.1) n = MIDI channel number: 0H-FH (ch.1-ch.16) * Not received when Rx.BANK SELECT = OFF. vv = Expression: 00H-7FH (0-127), Initial Value = 7FH (127) * “Rx.BANK SELECT” is set to OFF by “GM1 System On,” and Bank Select message will be ignored. * This adjusts the volume of a Part. It can be used independently from Volume messages. * “Rx.BANK SELECT” is set to ON by “GM2 System On.” Expression messages are used for musical expression within a performance; e.g., * “Rx.BANK SELECT” is set to ON by power-on Reset or by receiving “GS RESET.” expression pedal movements, crescendo and decrescendo. * When Rx.BANK SELECT LSB = OFF, Bank number LSB (llH) will be handled as 00H * Not received when Rx.EXPRESSION = OFF. (Initial value is ON) regardless of the received value. However, when sending Bank Select messages, you have to send both the MSB (mmH) and LSB (llH, the value should be 00H) together. .Hold 1 (Controller number 64) * Bank Select processing will be suspended until a Program Change message is received. Status 2nd bytes 3rd byte * The GS format “Variation number” is the value of the Bank Select MSB (Controller BnH 40H vvH number 0) expressed in decimal. * Some other GS devices do not recognize the Bank Select LSB (Controller number 32). n = MIDI channel number: 0H-FH (ch.1-ch.16) vv = Control value: 00H-7FH (0-127) * Not received when Rx.HOLD1 = OFF. (Initial value is ON) Copyright © 2007 ROLAND CORPORATION 1PSAll rights reserved. No part of this publication may be reproduced in any form without the written permission of ROLAND CORPORATION. 1 MIDI Implementation MIDI Implementation Portamento (Controller number 65) Status 2nd bytes 3rd byte BnH 41H vvH n = MIDI channel number: 0H-FH (ch.1-ch.16) vv = Control value : 00H-7FH (0-127) 0-63 = OFF, 64-127 = ON * Not received when Rx.PORTAMENTO = OFF. (Initial value is ON) .Sostenuto (Controller number 66) Status 2nd bytes 3rd byte BnH 42H vvH n = MIDI channel number: 0H-FH (ch.1-ch.16) vv = Control value: 00H-7FH (0-127) 0-63 = OFF, 64-127 = ON * Not received when Rx.SOSTENUTO = OFF. (Initial value is ON) .Soft (Controller number 67) Status 2nd bytes 3rd ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias