Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação Roland, Modelo HP-555G

Fabricante : Roland
Arquivo Tamanho: 57.43 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


* For Drum Parts, Program Change messages will not be received on bank numbers 12916384 (the value of Control Number 0 is other than 0 (00H)). Channel Pressure Status 2nd bytes DnH vvH n = MIDI channel number : 0H-FH (ch.1-ch.16) vv = Channel Pressure : 00H-7FH (0-127) * Not received when Rx.CH PRESSURE (CAf) = OFF. (Initial value is ON) * The resulting effect is determined by System Exclusive messages. With the initial settings there will be no effect. Pitch Bend Change Status 2nd byte 3rd bytes EnH llH mmH n = MIDI channel number : 0H-FH (ch.1-ch.16) mm, ll = Pitch Bend value : 00 00H - 40 00H - 7F 7FH (-8192 - 0 - +8191) * Not received when Rx.PITCH BEND = OFF. (Initial value is ON) * The resulting effect is determined by System Exclusive messages. With the initial settings the effect is Pitch Bend. Channel Mode Messages All Sounds Off (Controller number 120) Status 2nd byte 3rd bytes BnH 78H 00H n = MIDI channel number : 0H-FH (ch.1-ch.16) * When this message is received, all currently-sounding notes on the corresponding channel will be turned off immediately. Reset All Controllers (Controller number 121) Status 2nd byte 3rd bytes BnH 79H 00H n = MIDI channel number : 0H-FH (ch.1-ch.16) * When this message is received, the following controllers will be set to their reset values. Controller Reset value Pitch Bend Change +-0 (Center) Polyphonic Key Pressure 0 (off) Channel Pressure 0 (off) Modulation 0 (off) Expression 127 (max) Hold 1 0 (off) Portamento 0 (off) Sostenuto 0 (off) Soft 0 (off) RPN unset; previously set data will not change NRPN unset; previously set data will not change All Notes Off (Controller number 123) Status 2nd byte 3rd bytes BnH 7BH 00H n = MIDI channel number : 0H-FH (ch.1-ch.16) * When All Notes Off is received, all notes on the corresponding channel will be turned off. However if Hold 1 or Sostenuto is ON, the sound will be continued until these are turned off. OMNI OFF (Controller number 124) Status 2nd byte 3rd bytes BnH 7CH 00H n = MIDI channel number : 0H-FH (ch.1-ch.16) * The same processing will be carried out as when All Notes Off is received. OMNI ON (Controller number 125) Status 2nd byte 3rd bytes BnH 7DH 00H n = MIDI channel number : 0H-FH (ch.1-ch.16) * OMNI ON is only recognized as “All notes off”; the Mode doesn’t change (OMNI OFF remains). MONO (Controller number 126) Status 2nd byte 3rd bytes BnH 7EH mmH n = MIDI channel number : 0H-FH (ch.1-ch.16) mm = mono number : 00H-10H (0-16) * The same processing will be carried out as when All Sounds Off and All Notes Off is received, and the corresponding channel will be set to Mode 4 (M = 1) regardless of the value of “mono number.” HP 555G MIDI Implementation POLY (Controller number 127) Status 2nd byte 3rd bytes BnH 7FH 00H n = MIDI channel number : 0H-FH (ch.1-ch.16) * The same processing will be carried out as when All Sounds Off and All Notes Off is received, and the corresponding channel will be set to Mode 3. System Realtime Message Active Sensing Status FEH * When Active Sensing is received, the unit will begin monitoring the intervals of all further messages. While monitoring, if the interval between messages exceeds 420 ms, the same processing will be carried out as when All Sounds Off, All Notes Off and Reset All Controllers are received, and message interval monitoring will be halted. System Exclusive Message Status Data byte Status F0H iiH, ddH, ......, eeH F7H F0H :System Exclusive Message status ii = ID number :an ID number (manufacturer ID) to indicate the manufacturer whose Exclusive message this is. Roland’s manufacturer ID is 41H. ID numbers 7EH and 7FH are extensions of the MIDI standard; Universal Non-realtime Messages (7EH) and Universal Realtime Messages (7FH). dd,...,ee = data : 00H-7FH (0-127) F7H : EOX (End Of Exclusive) The System Exclusive Messages received by the HP555G are; messages related to mode settings, Universal Realtime System Exclusive messages and Data Set (DT1). System exclusive messages related to mode settings These messages are used to initialize a device to GS or General MIDI mode, or change the operating mode. When creating performance data, a “Turn General MIDI System On” message should be inserted at the beginning of a General MIDI score, and a “GS Reset” message at the beginning of a GS music data. Each song should contain only one mode message as appropriate for the type of data. (Do not insert two or more mode setting messages in a single song.) “Turn General MIDI System On and “Turn General MIDI System Off” use Universal Nonrealtime Message format. “GS Reset” use Roland system exclusive format “Data Set 1 (DT1).” . Turn General MIDI System On This is a command message that resets the internal settings of the unit to the General MIDI initial state (General MIDI System-Level 1). After receiving this message HP555G, will automatically be set to the proper condition for correctly playing a General MIDI score. Status Data byte Status F0H 7EH, 7FH, 09H, 01H F7H ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias