Log:
Assessments - 2, GPA: 3 ( )

Instruções de Operação Roland, Modelo JSQ-60

Fabricante : Roland
Arquivo Tamanho: 683.37 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


By using the REST and TIE Buttons, fairly complicated music pieces can be loaded. Therefore, you can chose either Step Load or Real time load mode. • It is possible to overdub on the existing data up to three times in Real time mode. • The Patch Shift of the Juno-60 or Patch Preset of the JP-8 can be memorized. • Tape Interface allows loading the data in the JSQ-60's memory onto an ordinary audio tape for storage and later retrieval. Features....................................................P- 2 Important Notes Power Supply ..............................................P- 3 Location..................................................P- 3 Cleaning..................................................P- 3 Others ...................................................p- 3 Fi ont Panel..................................................P. 4 Panel Description..............................................P. 5 Connection..................................................P. 6 Load and Playback.............................................P. 7 Real Time Load.............................................P. 7 Play/Repeat................................................P. 8 Tempo/Me tionome...........................................P. 8 Step Load.................................................P- 9 Edit....................................................P- 1 1 Continue Load.............................................P. 12 Overdub.................................................P. 13 Tape Interface...............................................P. 14 Save....................................................P. 1 5 Verify ..................................................P- 15 Load ...................................................P- 16 Application.................................................P. 16 Patch Shift ...............................................P. 1 7 Patch Preset..................................... ......P. 17 Start/Stop.............................................. ■ • P- 18 SYNC...................................................P- 18 MIDI .....................................................P. 18 Error.....................................................P. 19 Specifications ................................................P. 20 • Two Sync Out Jacks (DIN) allowing synchronization with another sequencer or the rhythm machine featuring Sync In, • Up to 2000 notes can be written into the JSQ-60, and the Memory Indicator tells you how much memory has been consumed so far. 2 IMPORTANT POWER SUPPLY LOCATION CLEANING OTHERS • The JSQ-60 adapts AC powered system. Be sure to use the supplied AC Adaptor Using any other adaptor will cause malfunction or even break down. • Do not turn the JSQ-60 on, before connecting the AC Adaptor to it. • This unit might not work properly if turned on immediately after turned off. If this happens, simply turn it off again and turn it on a few seconds later. • Before setting up the JSQ-60 with an external synthesizer, be sure to turn both of them off. • Using the JSQ-60 near a neon or fluorescent lamp may cause noise interference, If so, change the angle or position of the JSQ-60. • Avoid using the JSQ-60 in extreme heat or humidity or where it may be affected by dust. • Use a soft cloth and clean only with a mild detergent. • Do not use solvents such as paint thinner. • If the AC Adaptor is connected, turning the Power Switch off does not erase the data in memory, but in about a day after the AC Adaptor is disconnected, its data will be completely erased. So it may be a good idea to load all data onto a cassette tape for precaution. • Do not pull the DCB cord hard. 3 © Power Switch ô I Reset/Verify Button ) Mode Switch ) Tempo Knob Metronome Level Switch : Memory Indicators POWER MODE PLAY ONLY (PROTECT) TEMPO LOAD/ PLAY METRONOME LEVEL HIGH -LOW -OFF MEMORY 25 5 0 75 90 FULL SLOW LOAD MODE over ; 4/4 3/4 DUB . I—I I—I I—i I—I I—1 H=l- RESET LOAD STOP PLAY REPEAT PLAV REALTIME Ô Ô O MODE SELECT @ Repeat/Play Switch Play/Save Button I Stop Button (7) Load Button > Load Mode Indicators ' Measure End Button Rest Button I Tie Button @ Load Mode Selector Button 4 © Power Switch Pushing this switch on will light up the Indicator and turns the JSQ-60 on. @ Mode Switch The JSQ-60 includes two modes for sequencer, and a mode for loading the sequencer data onto a tape as follows. • Play Only (Protect) mode This mode is to playback the data you have written into the-sequencer, but writing is not possible in this mode. To protect the data from accidental loss, always turn the JSQ-60 into this mode except when loading. • Load/Play mode This mode is for loading, playing back, editing and overdubbing. • Tape mode This mode is for saving sequencer data onto a tape, and later loading it back to the sequencer. < NOTE > Be sure that the JSQ-60 is not running while changing the modes. The data will be erased if ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias