Log:
Assessments - 4, GPA: 4 ( )

Instruções de Operação Roland, Modelo RE-100

Fabricante : Roland
Arquivo Tamanho: 1.18 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


should be adjusted bv instrument volume dial, Electronic organ. Amplifier, Tape recorder Player, etc. Switches echo sounds ON/OFF while playing and when switched to ON., level meter is illuminated. When Foot Switch is not connected, echo is ON. Foot Switch P. A., Vocal amp AMP. Guitar amp, etc. MODE SELECTOR • RE-100 Dials 1 io 3 ¿re for Repeat ttape type) and 4 to 6 are for swelling sound. Choose best dial according to lesjred results. • RE-200 V . Dials 1 to 4 are for Repeat (tape type) and 5 to 11 are for Repeat and Reverb (spring type) all of whicts function simultaneously. REVERB ONLY is for reverberation. Choose best dial according to desired results. INTENSITY CONTROL When knob is turned clockwise, echo repeat number increases but overturning- makes howling and bad articulation. REPEAT RATE CONTROL Adjusts repeat times. Turning the knob counterclockwise prolongs repeat time and turning it clockwise shortens it. It is so adjusted that the best tone quality can be obtained whetV the point is at the center of graduation (double line). ECHO VOLUME CONTROL Posit™ where bes, ,one Adjusts echo depth. Turning fully counterclockwise -JIJ}- qua]lty can be obtained. produces original tone and clockwise turning produces echo. REVERB VOLUME CONTROL (RE-200 only) Turning fully counterclockwise produces original tone and clockwise turning produces reverberation. Functions only when the Mode Selector dial is at 5 to 11 and at REVERB ONLY. TREBLE CONTROL Turning dial counterclockwise, high tone is diminished and turning it clockwise, it is increased. Appropriate tone quality can be obtained around the center of graduation (double line). BASS CONTROL Turning dial counterclockwise, low tone is diminished and turning it clockwise it is increased. Appropriate tone quality can be obtained around the center of graduation (double line;. STANDBY SWITCH Controls tape movement. When the switch lever is pushed upward, tape moves to activate echo function and when it is pushed downward, tape stops and echo does not function. When echo is not necessary, the switch lever should be pushed downward in order to assure long lives of head and tape. When playing, it is very convenient to use Foot Switch for echo ON/OFF control. POWER SWITCH Can be used also for grounding. When the lever position is either up or down, power is ON, but when it is at the center, power is OFF. When excessive hum is generated or static electricity affects microphone or other instruments, change the lever position to opposite side. OUTPUT LEVEL CHANGEOVER SWITCH Can be changed over 3 steps namely H (max.), M (middle), and L (min.), so properly set according to kind of amplifier which is connected to output jack. PEAK LEVEL M^TER (RE-200 only) Detects a short time impact noise which cannot be indicated in conventional level meters and lights when input is oversupplied (sound distorts). When the peak level meter lights, adjust input volume (INSTRUMENT, MIC) by turning counterclockwise so that the peak level meter doesn’t light. TAPE Magnetic tape attached to Space Echo is of endless variety (RE-4, product of Sony Corp.j. Tape which is damaged and distorts sound quality may damage to the head, so be sure to replace the tape when tone quality is distorted. In addition, cleaner should be replaced when changing the tape. HEAD ; A dirty head may result in distorted tone quality and may cause damage to the tape. It should be cleaned by using a cleaner rod or soft cloth wfith alcohol. Be sure not to bring a magnetized screwdriver near head because it may magnetize the head and cause noise generation. Warning, the head is precisely adjusted, therefore, do not jjress it with a strong force." FEATURES (DRE-100 and RE-200 Thanks to employed full-truck, 2 channel head, noise is eliminated and tone quality is highly enhanced. Due to the special head circuit, external noise which comes in from head is greatly reduced. Level meter yhich incorporates lamp interlocking foot switch indicates echo ON and OFF in accordance with illuminated or extinguished condition of meter light. ©RE-200 Thanks to the imported spring system Reverb Unit, a natural reverberation effect can be obtained. A light emitting diode is employed in the Peak Level Meier, thus it can detect a quick starting impuls sound such as produced by electric guitar, percussion instruments, and others, which cannot be indicated by conventional meters. PREPARATIONS Before plugging in the AC socket, ensure that the tape is set as illustrated below by opening the top cover of the case. Then, fully turn each knob counterclockwise. If the Space Echo generates noise after installation, changing the location or poiiucn is indicated to correct situation. * ADJUSTMENT MIC VOLUME and INSTRUMENT VOLUME The volume knob should be adjusted so that the pointer of the level meier does not exceed 0 at the maximum volume. SPACE- ECHO SPECIFICATIONS MODEL RE-100 Input Jack 5 pcs(for Mi...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias