Log:
Assessments - 1, GPA: 5 ( )

Instruções de Operação Roland, Modelo SP-700

Fabricante : Roland
Arquivo Tamanho: 14.77 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


When it is set to “ - ”, they are ignored. * You can set all channels to the same number by moving the cursor to “All” and pressing IS1/DEC | or | S2/INC |. This is convenient when you want to have sounds on all channels respond to the same MIDI data. * When the I SHIFT | indicator is dark, you can set whether Program Change messages are received or not by rotating the | VALUE/CURSORldial. 15. Press | PERFORMANCE | to select the Performance Mode page. 16. Patches are changed by reception of Program Change messages (program numbers 1 — 128) over the Part channel. 4-18 CHANGING THE SOUND PROGRAMS BY MIDI MESSAGES Replacing Volume Memory Sections Changing Volumes (Loading) Only one Volume can be loaded at a time into each Volume memory (cr p.2 - 3) When using the SP - 700 in the Performance Mode, the Volume can be loaded from the current drive by reception of a Program Change message over the control channel. The program numbers to be used for loading a Volume are 65 —128. The Volume which is assigned to the same program number as the received program number will be loaded. ♦ When loading a Volume with a MIDI Program Change message, the Message page will not appear, unlike when loading a Volume from the panel. Load the Volume after erasing all sound data in the destination Volume memory. Be careful, since all edited data will be lost if you load the new Volume without saving. The destination Volume memory is determined by the Control Mode (cr P.Sys -11). The following three Control Modes are available: [Perf] In this mode, Performances are changed. ♦ Since a Volume cannot be loaded, do not select this setting when you wish to load a Volume. ♦ When a Bank Select message and Program Change message are received, the Bank Select message is ignored. [Perf/Volum] In this mode, the Volume in the current drive which has the same program number as the received program number (65—128) is loaded into the current Volume memory. ♦ No sound can be output while a Volume is being loaded. ♦ When the received program number is from 1—64, the Performance in the current Volume memory will be changed. ♦ When receiving a Program Change message from 1 —64 after receiving the Bank Select message, the Volume memory sections are switched and the Performance is changed to the one that corresponds to the received program number. ♦ When a Bank Select message and Program Change message from 65—128 are received, the Bank Select message is ignored. 4 - 19 CHANGING THE SOUND PROGRAMS BY MIDI MESSAGES [Perf/Vo!um2] In this mode, the Volume in the current drive which has the same program number as the received program number (65—128) is loaded into the Volume memory not currently selected. ♦ If the Load - while - playing function is set to ON, sound can be output even while loading. When it is set to OFF, no sound can be output at all. ♦ If the Volume B memory has not been set for use (when set to 0 megabytes), a new Volume cannot be loaded into Volume B memory. ♦ When the received program number is from 1—64, the Performance in the current Volume memory will be changed. ♦ When receiving a Program Change message from 1 —64 after receiving the Bank Select messages, the Volume memory sections are switched and the Performance is changed to the one which corresponds to the received program number. ♦ When a Bank Select message and Program Change message from 65—128 are received, the Bank Select message is ignored. Related Parameters Control channel (<=r P.Sys -11) Control mode (a- P.Sys -11) Current drive (o- P.Disk - 3) Program number of Volume (a- P.Disk - 27) Load - while - playing function (a- p.Sys - 4) Volume A (<=r p.Sys - 5) Current Volume memory (cr P.Sys -1) To change a Volume 1 - Press [ SYSTEM~lto select the System Mode page. 2. Press) F3]MIDI to select the MIDI control page. СMIDI Control -Bfitfornl Bec/lnc in P 31-' -5 Pi б11.- 0 Г 1 Control Channel Control Mode Intornation _ COff3Ci"163 2 CüPerfí C2: Per f/'Volum] PRM 1 BSH MIDI 1 Uol ID 1 1 L.D. 5U 3. Move the cursor to the control channel (Control Channel). 4. Assign the control channel by pressing | SI/DEC)or| S2/INC |. The Volume is loaded by the Program Change message received over the control channel set here. ♦ Do not set the control channel to the same value as that of the MIDI channel of the Part. Since the Program Change message of the control channel has priority, if they are the same, the Patch of the Part cannot be changed. 4-20 CHANGING THE SOUND PROGRAMS BY MIDI MESSAGES ♦ When the control channel is set to Off, the Volume cannot be loaded by Program Change messages. ♦ When the | SHIFT | indicator is dark, set the control channel by rotating the [VALUE/CURSOR (dial. 5. Move the cursor to the Control Mode using the cursor buttons. 6. Set the Control Mode to either 2 (Perf/Volum) or 3 (Perf/Volum2) by pressing | S1/DEC [ or IS2/INC*]. ♦ When this is set to 1 (Perf), the Volume cannot be loaded by Program Change m...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias