|
por este dispositivo também tem outras instruções :
Facilidade de uso
Reception must occur correctly whether or not the status byte is omitted. LS9-16/32 Manual de instrucciones Formato de datos MIDI Formato de datos MIDI PROGRAM CHANGE (Cn) Reception If [PROGRAM CHANGE ECHO] is ON, bank select messages will also be echoed from MIDI OUT. If SINGLE CH is selected, these messages are received if [PROGRAM CHANGE Rx] is ON and the [Rx CH] matches. However if [OMNI] is ON, these messages are received regardless of the channel. When these messages are received, scene memory and effect library are recalled according to the settings of the [PROGRAM CHANGE EVENT LIST]. Transmission If [PROGRAM CHANGE Tx] is ON, these messages are transmitted according to the [PROGRAM CHANGE Table] settings when scene memory and effect library are recalled. If SINGLE CH is selected, these messages are transmitted on the [Tx CH] channel. If the recalled scene memory and effect library has been assigned to more than one PROGRAM NUMBER, the lowest-numbered PROGRAM NUMBER for each MIDI channel will be transmitted. PROGRAM CHANGE messages are not used for transmission to LS9 Editor because there is no guarantee that the contents of the assignment tables will match. (PARAMETER CHANGE messages are always used.) You can choose either MULTI MIDI CH or SINGLE CH. If SINGLE is selected You can choose the Rx CH, OMNI CH, and Tx CH. You can choose whether a bank select message will be added. A bank of up to 16 can be specified. If MULTI is selected The Rx and Tx channels will be the same. The assignment table will use the settings for each MIDI channel. Bank select messages will not be added. You can make settings for up to sixteen MIDI channels. STATUS 1100nnnn Cn Program change DATA 0nnnnnnn nn Program number (0-127) 2 SYSTEM REALTIME MESSAGE 2.1 SONG SELECT (F3) Select the track number shown in the TITLE LIST screen of the USB memory recorder. STATUS 11110011 F3 Song select Song number0sssssss ss Song number (0-127) 2.2 TIMING CLOCK (F8) Reception This message is used to control effects. This message is transmitted twenty-four times per quarter note. Echoing of this message depends on the OTHER item in the ECHO settings. STATUS 11111000 F8 Timing clock 2.3 ACTIVE SENSING (FE) Reception Once this message has been received, MIDI communication will be initialized (e.g., Running Status will be cleared) if no message is received for an interval of 400 ms. This message is not subject to echoing. STATUS 11111110 FE Active sensing 2.4 SYSTEM RESET (FF) Reception When this message is received, MIDI communication will be initialized (e.g., Running Status will be cleared). This message is not subject to echoing. STATUS 11111111 FF System reset 3 SYSTEM EXCLUSIVE MESSAGE 3.1 MMC < MMC STOP > Reception If the [DEVICE NO.] matches or is 7F, receives this message and stops. STATUS 11110000 F0 System exclusive message ID No. 01111111 7F Real time System exclusive Device ID 0ddddddd dd Destination (00-7E, 7F:all call) COMMAND 00000110 06 Machine Control Command(MCC) sub-id 00000001 01 Stop(MCS) EOX 11110111 F7 End of exclusive < MMC PLAY > Reception If the [DEVICE NO.] matches or is 7F, receives this message and starts playback. STATUS 11110000 F0 System exclusive message ID No. 01111111 7F Real time System exclusive Device ID 0ddddddd dd Destination (00-7E, 7F:all call) COMMAND 00000110 06 Machine Control Command(MCC) sub-id 00000010 02 Play(MCS) EOX 11110111 F7 End of exclusive < MMC DEFERED PLAY > Reception If the [DEVICE NO.] matches or is 7F, receives this message and starts playback. STATUS 11110000 F0 System exclusive message ID No. 01111111 7F Real time System exclusive Device ID 0ddddddd dd Destination (00-7E, 7F:all call) COMMAND 00000110 06 Machine Control Command(MCC) sub-id 00000011 03 Deferred Play(MCS) EOX 11110111 F7 End of exclusive < MMC RECORD STROBE > Reception If the [DEVICE NO.] matches or is 7F, receives this message, and if stopped, starts recording. STATUS 11110000 F0 System exclusive message ID No. 01111111 7F Real time System exclusive Device ID 0ddddddd dd Destination (00-7E, 7F:all call) COMMAND 00000110 06 Machine Control Command(MCC) sub-id 00000110 06 Record strobe EOX 11110111 F7 End of exclusive < MMC PAUSE > Reception If the [DEVICE NO.] matches or is 7F, receives this message, and if playing, pauses. STATUS 11110000 F0 System exclusive message ID No. 01111111 7F Real time System exclusive Device ID 0ddddddd dd Destination (00-7E, 7F:all call) COMMAND 00000110 06 Machine Control Command(MCC) sub-id 00001001 09 Pause(MCS) EOX 11110111 F7 End of exclusive Apendices 261 LS9-16/32 Manual de instrucciones Formato de datos MIDI Formato de datos MIDI BULK DUMP Command rx/tx Function F0 43 0n 3E cc cc 12 mm … mm dd dd rx/tx BULK DUMP … ee F7 DATA F0 43 2n 3E 12 mm … mm dd dd F7 rx BULK DUMP REQUEST The LS9 uses the following data types for a bulk dump. Module Name(mm) Data Number(dd) SCENE LIB “SCENE___” *1) *14) *15) INPUT EQ LIB “INEQ____” *2) *7) *8) OUTPUT EQ LIB “OUTEQ___” *3) *9) *10) *11) Dynami...
Este manual também é adequado para os modelos :Instrumentos musicais - LS9-16 (6.68 mb)