Log:
Assessments - 3, GPA: 3 ( )

Instruções de Operação Casio, Modelo WK-210

Fabricante : Casio
Arquivo Tamanho: 4.04 mb
Arquivo Nome :
Língua de Ensino: en
Fotos e especificações  Casio  WK-210
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


If an error repeats a number of times (three times or more for this Instrument), either the sending device or the receiving device sends an RJC to terminate the session. A session ends after the sending device transfers the volume of data determined by the number of parameter sets being transferred, and sends EOD and EOS in response to an ACK from the sending device. Data Receiver Data Sender Operation HBR > Send Request (Optional) < HBS Data Send ACK > Acknowledge < HBS Data Send ACK > Acknowledge : : ACK > Acknowledge < EOD End of Data : Other subsessions : < EOS End of Session 34 The packed with the same packet number is resent when a checksum mismatch or incompatible data format error is detected. Data Receiver Data Sender HBR > < HBS ACK > < HBS ERR > < HBS ERR > < HBS ACK > : : ACK > < EOD : Other subsessions : < EOS Session terminates if ERR is detected a number of times. Data Receiver Data Sender HBR > < HBS ACK > < HBS (Error generated) ERR > < HBS (Error generated) ERR > < HBS (Error generated) ERR > < HBS (Error generated) RJC > Operation Send Request (Optional) Data Send Acknowledge Data Send 1 Error Data Send 2 (Retry 1) Error Data Send 3 (Retry 2) Acknowledge Acknowledge End of Data End of Session Operation Send Request (Optional) Data Send Acknowledge Data Send Error Data Send (Retry 1) Error Data Send (Retry 2) Error Data Send (Retry 3) Session stopped 35 RJC is sent to terminate the session in case ACK cannot be recognized. Data Receiver Data Sender Operation HBR > Send Request (Optional) < HBS Data Send : (Fixed amount of time elapses) RJC < Timeout error The session can be canceled for any reason by sending an RJC. RJC can be sent by the sending device or the receiving device. The bulk dump session is terminated immediately upon receipt of an RJC. Data Receiver Data Sender Operation HBR > Send Request (Optional) < HBS Data Send ACK > Acknowledge < HBS Data Send : : (Terminate operation) RJC > Data Receive Canceled Data Receiver Data Sender Operation HBR > Send Request (Optional) ACK > Acknowledge < HBS Data Send ACK > Acknowledge < HBS Data Send : : (Terminate operation) < RJC Data Send Canceled BSY is returned to the external device when OBS, OBR, HBS, or HBR is sent while the Instrument mode is not suitable to perform bulk dump, etc. After BSY is received, the external device should wait until the Instrument enters a mode in which the session is enabled. Data Receiver Data Sender Operation OBR > Send Request < BSY Send Rejected 36 Data Receiver Data Sender < OBS BSY > Data Receiver Data Sender HBR > < BSY Data Receiver Data Sender < HBS BSY > Operation Data Send Receive Rejected Operation Send Request Send Rejected Operation Data Send Receive Rejected 37 Part V Parameter List This section explains the parameters that actually can be transferred by the Instrument. 22 Using the Parameter List • Parameter field Shows the parameter name. • ID field Shows the parameter ID as a hexadecimal number. • R/W field Shows "R" to indicate that an IPR (Individual Parameter Request) read operation (Read) is possible or "W" to indicate that an IPS (Individual Parameter Send) write operation is possible. • Block field Shows the bit field allocation of the block number. The bit field position is shown as a decimal format number. • Size field Shows the parameter bit width as a decimal format value. • Array field Shows the parameter array size as a hexadecimal value. • Min-Def-Max field Shows the minimum value, default value, and maximum value for parameter acquisition as a hexadecimal value. • Description field Explains the meaning of parameter values. Unless otherwise specified, setting values are all indicated in decimal format. 23 System Parameters These parameters make it possible for an external device to check the status of the Instrument and for an external device to command some operation of the Instrument. 23.1 System Information Parameter This parameter is a container for system information. Parameter ID R/W Block Size Array Min-Def-Max Description Model Name 0000 R 000000 7 08 00-20-7F Ascii Character CTK-4000 ..."CTK-4000" CTK-5000 ..."CTK-5000" LK-205 ....."LK-205 " LK-270 ....."LK-270 " WK-200 ....."WK-200 " WK-210 ....."WK-210 " WK-500 ....."WK-500 " CDP-200R ..."CDP-200R" Program Revision 0001 R . 7 08 00-20-7F Ascii Character Ex. " 12345" General Register 0002 R/W . 8 01 00-00-FF General-purpose register for communication test 38 23.2 Data Management Parameter These are information acquisition and operation command parameters for this Instrument's Data Manager PC application. Parameter ID R/W Block Size Array Min-Def-Max Description Ps Category 0005 W 000000 7 01 00-00-7F Specifies the category ID of the parameter set that corresponds to an operation. Ps Memory 0006 W ^ 7 01 00-00-7F Specifies the memory ID ofthe parameter set that corresponds to an operation. Ps Number 0007 W ^ 14 01 0000-0001-3FFF Specifies the number of the parameter set that corresponds to an operation. Ps Data Type 00...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias