|
Instruções de Operação Campbell Hausfeld, Modelo PA208501
Fabricante : Campbell Hausfeld Arquivo Tamanho: 398.59 kb Arquivo Nome : db2a1669-0dfd-4afb-905c-24a181976daa.pdf
|
|
|
|
Ir para baixar
Facilidade de uso
Campbell Hausfeld’s warranties are void in the event of misapplication and assumes no responsibility for any resulting loss. Specifications Maximum pressure: 150 PSIG (10 bar). Maximum temperature: 125°F (52°C). Installation Disconnect power and release all pressure from the system before attempting to install, service, relocate or perform any maintenance. 1. The air cleaner/dryer should be located as close as possible to the air tool or spray gun. 2. A shutoff valve should be installed before the air cleaner/dryer so the unit can be easily depressurized for servicing. Securely mount the air cleaner/dryer in a vertical position using the mounting bracket supplied with the unit. Figure 1 Service Indicator Mounting Bracket Coalescing Filter Dryer 3. Install a Campbell Hausfeld 3/8” Filter (PA2121) before and after the coalescing filter/dryer for optimum performance. Connect the piping or hose with airflow in the direction of the arrows cast into the top of the unit. Avoid using unnecessary fittings, couplings, etc., that restrict air flow. 4. Remove the bowl from the dryer housing by pushing the bowl toward the body and rotating bowl. Pull bowl down to remove from housing. 5. Open bag of desiccant and pour into bowl. Shake or tap bowl periodically to settle desiccant. Fill to within 1/2” from top of bowl. Do not allow desiccant to get into center tube. 6. Reinstall bowl on housing. Be sure it is securely locked in place before pressurizing the unit. 7. The coalescing filter is supplied with the filter element preinstalled. 8. Be sure to use a clean air hose to prevent contamination of the cleaned air. 9. Pressurize system and check for any air leaks. Operation Before turning on the air pressure supply, make certain the bowls are securely locked in place and all fittings are tight. © 1999 Campbell Hausfeld/Scott Fetzer For parts, product & service information IN245501AV 5/99 visit Air Cleaner / Dryer Air Cleaner / Dryer Maintenance Always depressurize the unit before removing any bowl or personal injury and/or property damage could occur. 1. Drain moisture from coalescing filter before every use. To drain, turn drain valve. Make sure system pressure is 10 psig or less. 2. The only other servicing required for the air cleaner/dryer is replacement of the desiccant when the desiccant turns pink, and replacement of the filter element when the service indicator shows red. 3. Desiccant Replacement a. Shut off air flow to the air cleaner/dryer and depressurize system. b. Remove bowl from the dryer housing by pushing the bowl toward the body and rotating bowl counterclockwise. Pull bowl down to remove from housing. c. Pour out used desiccant. d. Pour new desiccant into bowl, filling to within 1/2” of the top of the bowl. Do not allow desiccant to get into center tube. e. Reinstall bowl on housing. Be sure it is securely locked in place before pressurizing the unit. 4. Coalescing Filter Replacement - The service indicator on the coalescing filter (shown in Figure 1) signals when the filter element needs to be replaced. When the indicator turns red the filter element must be replaced. Use replacement filter element PA2087. a. Shut off air flow to the air cleaner/dryer and depressurize system. b. Remove bowl from from the dryer housing by pushing the bowl toward the body and rotating bowl counterclockwise. Pull bowl down to remove from housing. c. Remove used filter element by grasping the bottom of filter element and turning counterclockwise. d. Install new filter element making sure o-ring is properly seated in groove. Always handle the element by the bottom of filter element. Do not touch the foam plastic cover. Pressure on the outer foam cover can damage it once it is in service. e. Filter elements cannot be cleaned. A new filter element must be used. Reinstall bowl on housing. Be sure it is securely locked in place before pressurizing the unit. Technical Service For information regarding the operation or repair of this product, please call 1-800-543-6400 between 8 a.m. and noon or between 1 p.m. and 5 p.m. (EST), Monday through Friday for assistance. If you are calling from Ohio or outside the continental United States, please call collect, 1-513-3671182. Limited Warranty 1. DURATION: From the date of purchase by the original purchaser as follows: Standard Duty Products - One Year, Serious Two Years, Extreme Duty Products - Three Years. 2. WHO GIVES THIS WARRANTY (WARRANTOR): Campbell Hausfeld / Scott Fetzer Company, 100 Production Drive, Harrison, Telephone: (800) 543-6400 3. WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser (other than for purposes of resale) of the Campbell Hausfeld product. 4. WHAT PRODUCTS ARE COVERED BY THIS WARRANTY: Any Campbell Hausfeld nailer, stapler, air tool, spray gun, inflator or air accessory supplied or manufactured by Warrantor. 5. WHAT IS COVERED UNDER THIS WARRANTY: Substantial defects in material and workmanship which occur within the durati...
Escreva a sua própria avaliação do dispositivo
|
|