Log:
Assessments - 2, GPA: 3.5 ( )

Instruções de Operação Boss Audio Systems, Modelo SP-505

Fabricante : Boss Audio Systems
Arquivo Tamanho: 2.12 mb
Arquivo Nome : 2a6b0e4c-c94b-4cf9-bacf-3bf50a1815f9.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


For example, if a sample contains noise, you can lower the volume of the region containing the noise, to make it less obtrusive. * The tonal quality may change if you perform this operation repeatedly. * While you are adjusting the volume of a specified region in the sample, the Play BPM setting will be ignored, and the sample will play at its original BPM (tempo). 1. Press the pad of the sample whose volume you want to adjust for a specified region. 2. Press [WAVE EDIT]. 3. Press [F2] (AMP). The sample waveform will be displayed. The pad number will be shown at the left side of the top line of the display. (Example) PAD 6-1: Pad [1] of pad bank 6 The number of samples of the wave pointer position will be shown in the right side of the top line of the display. * Even if the sample has been set to reverse playback, the waveform will be displayed in the normal direction. 4. Use CURSOR [<][>] to move the entire screen left or right, use the VALUE dial to move the wave pointer to the beginning of the region for which you want to change the volume, and then press [F1] (START). * When wave pointer locates on except the region between the specified start and end points, the display will indicate [*********], and it is not possible to set the beginning of the region for which you want to change the volume. Wave Pointer Number of Samples The region between the specified start and end points 4 47 Chapter 4. Changing the settings of a sample Chapter 4. Changing the settings of a sample . Use CURSOR [<][>] to move the entire screen left or right, use the VALUE dial to move the wave pointer to the end of the region in which you want to change the volume, and then press [F2] (END). The region between the specified start and end points will be highlighted. * When wave pointer locates on except the region between the specified start and end points, the display will indicate [*********], and it is not possible to set the end of the region for which you want to change the volume. . If you want to make fine adjustments to the start and end points of the region in which the volume will be adjusted, press [ZOOM IN] to magnify the waveform display, use the VALUE dial to move the wave pointer, and press [F1] (STRT) or [F2] (END). Press [ZOOM OUT] to reduce the magnification of the waveform display, returning to the previous display size. . By holding down [L/R] and pressing [ZOOM IN] [ZOOM OUT], you can zoom-in or zoom-out on the vertical axis (amplitude axis) of the waveform. 6. Press [F3] (ADJUST). Use the VALUE dial to adjust the volume. 7. Use the VALUE dial to adjust the volume. Amplify: 0–400 A setting of 400 will double the amplitude of the waveform, and 0 will produce an amplitude of 0. By pressing [F3] (PREVIEW) you can preview the volume that will result. * The sound will be played starting slightly before the specified start point, for a maximum of nine seconds. 8. When you are finished adjusting the volume, press [F1] (EXECUTE). To cancel, press [F2] (CANCEL) or [EXIT]. The volume will revert to the original settings. If you pressed [F1] (EXECUTE), you will be asked to confirm the volume change. 9. To finalize your change in the volume, press [F1] (YES). To cancel, press [F2] (NO). * Once you have finalized the volume change, it is not possible to return to the original volume. 10. Press [SONG] or [PTN], or press [EXIT] twice to return to the Play screen. Never turn off the power while the display indicates “Keep Power On!” Chapter 5. Deleting or copying a sample Chapter 5. Deleting or copying a sample e 1. Press [SONG] or [PTN] to access the Play screen. 2. Press [DEL]. 3. Press the pad whose sample you want to delete. You may select more than one pad. If you want to select a sample of another pad bank, switch pad banks (p. 30) and then press a pad to select the sample. Will not be deleted (white) Selected for deletion (black) No sample is assigned (dotted line) If you press a selected pad once again, the display will change back to white, canceling the selection. 4. To delete the selected sample(s), press [F1] (EXECUTE). To cancel, press [F2] (CANCEL) or [EXIT]. Never turn off the power while the display indicates “Keep Power On!” Using the clipboard to copy a sample The “clipboard” is a function that temporarily stores a desired sample. You can use this function to copy a sample. This is convenient when you want to copy between different pad banks, or to swap (exchange) the location of samples. Copying a single sample 1. Press [SONG] or [PTN] to display the Play screen. 2. Hold down the pad of the sample that you want to copy, and press [CLIPBOARD]. The sample will be copied to the clipboard, and [CLIPBOARD] will light. When you press [CLIPBOARD], the copied sample will play. 3. Hold down [CLIPBOARD] and press the copy- destination pad. . If you want to copy to a different pad bank, press [PAD BANK] to switch the pad bank. (p. 30) . If the copy-destination pad contains a sample, you will be asked “OK to Overwrite?”...

Este manual também é adequado para os modelos :
Instrumentos musicais - SP-505 (2.12 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias