Log:
Assessments - 2, GPA: 4.5 ( )

Instruções de Operação Pentair, Modelo INTELLIFLO VS-3050

Fabricante : Pentair
Arquivo Tamanho: 3.06 mb
Arquivo Nome : intelliflo-owners.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Regardless of the length of time between filter cleaning, it is most important to visually inspect the hair and lint pot basket at least once a week. A dirty basket will reduce the efficiency of the filter and possibly the heater. WARNING — DO NOT open the strainer pot if pump fails to prime or if pump has been operating without water in the strainer pot. Pumps operated in these circumstances may experience a build up of vapor pressure and may contain scalding hot water. Opening the pump may cause serious personal injury. In order to avoid the possibility of personal injury, make sure the suction and discharge valves are open and that the strainer pot is cool to the touch, then open with extreme caution. CAUTION — To prevent damage to the pump and filter and for proper operation of the system, clean pump strainer and skimmer baskets regularly. Pump Strainer Basket Service If the IntelliFlo pump is installed below the water level of the pool, close the return and suction lines before opening the hair and lint pot on the pump. 1. Press the Stop button to stop the pump and switch off the pump at the circuit breaker. 2. Disconnect the communication cable from the IntelliFlo pump. 3. Relieve pressure in the system. 4. Turn the clamp and lid in a counterclockwise direction until it stops. 5. Remove the clamp and lid. 6. Remove the basket and put the debris into the trash and rinse out the basket. If the basket is cracked, replace the basket. 7. Replace the basket and fill the pump pot and volute with water up to the inlet port. 8. Clean the cover, o-ring, and sealing surface of the pump pot. Grease the o-ring with Teflon or silicone lubricant. 9. Reinstall the lid by placing the clamp and the lid on the pot. IntelliFlo VS-3050 Installation and User’s Guide Pump Strainer Basket Service (Continued) 10. Ensure that the lid o-ring is properly placed. Seat the clamp and lid then turn clockwise until the handles are horizontal as shown. 11. Reconnect the communication cable to the pump if required. 12. Switch the power ON at the circuit breaker. Reset the pool time clock to the correct time. WARNING — FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATING SYSTEM (e.g., LOCK RING, PUMP, FILTER, VALVES, ETC.) IS SERVICED, AIR CAN ENTER THE SYSTEM AND BECOME PRESSURIZED. PRESSURIZED AIR CAN CAUSE THE LID TO BLOW OFF WHICH CAN RESULT IN SEVERE INJURY, DEATH, OR PROPERTY DAMAGE. TO AVOID THIS POTENTIAL HAZARD, FOLLOW THESE INSTRUCTIONS. 13. Open the manual air relief valve on top of the filter. 14. Stand clear of the filter. Press the Start button on the pump. 15. Bleed air from the filter until a steady stream of water comes out. 16. Close the manual air relief valve. Motor Service 1. Protect from heat: • Shade the motor and controller from the sun. • Any enclosure must be well ventilated to prevent overheating. Particular attention should be paid to the motor fan cover and the cooling fins between the drive and the motor. • Provide ample cross ventilation. 2. Protect against dirt: • Protect from any foreign matter or splashing water. • Do not store (or spill) pool chemicals near the motor. • Avoid sweeping or stirring up dust near the motor while it is operating. • If a motor has been damaged by dirt it voids the motor warranty. 3. Protect against moisture: • Protect from splashing pool water. • Protect from the weather. • Protect from lawn sprinklers. • If a motor has become wet - let it dry before operating. Do not allow the pump to operate if it has been flooded. • If a motor has been damaged by water it voids the motor warranty. Note: DO NOT wrap motor and controller with plastic or other air tight materials. The motor and controller may be covered, but not wrapped in plastic, during a storm, for winter storage, etc., but never when operating, or expecting operation. When replacing the motor, be certain that the motor support is correctly positioned to support the size of motor being installed. IntelliFlo VS-3050 Installation and User’s Guide Winterizing To protect the IntelliFlo pump electronics from damage due to freezing conditions, the pump will switch it self on to generate internal heat when the air temperature drops below 40° F. This feature is not intended to protect the system plumbing from freezing. 1. If the air temperature drops below 40° F the water in the pump can freeze and cause damage. Freeze damage is not warrantable. 2. To prevent freeze damage follow the procedures listed below. • Shut off electrical power for the pump at the circuit breaker. • Drain the water out of the pump by removing the two thumb-twist drain plugs located at the bottom of the volute. Store the plugs in the pump basket. • Cover the motor to protect it from severe rain, snow and ice. • Do not wrap the motor in plastic. It will cause condensation and rust on the inside of the motor. Note: In mild climate areas, when temporary freezing conditions may occur, run your filtering equipment all night to prevent freezing....


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias