Log:
Assessments - 2, GPA: 4.5 ( )

Instruções de Operação Hitachi, Modelo 1800

Fabricante : Hitachi
Arquivo Tamanho: 1.05 mb
Arquivo Nome : 46543912-4c01-4356-b53f-6e1572112b5d.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Save these instructions. See page 3 for model information, including maximum working pressure. TI8900a TI8885a II 2 G Contents Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Dura-Flo Pumps with NXT™ Air Motors . . . . . . . 3 Dura-Flo Pumps with Viscount® Hydraulic Motors 5 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Flush Before Using Equipment . . . . . . . . . . . . . .8 Mounting Accessories . . . . . . . . . . . . . . . . . . . . . 8 Hoses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Air LineAccessories . . . . . . . . . . . . . . . . . . . . . .9 Hydraulic LineAccessories . . . . . . . . . . . . . . . . . 9 Fluid Line Accessories . . . . . . . . . . . . . . . . . . . .9 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 PressureRelief Procedure . . . . . . . . . . . . . . . . 12 Trigger Lock. . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Preventive Maintenance Schedule . . . . . . . . . . 14 Wet-Cups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Flushing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Corrosion Protection . . . . . . . . . . . . . . . . . . . . .14 Hydraulic Systems . . . . . . . . . . . . . . . . . . . . . . .14 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Required Tools . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Disconnect the Lower . . . . . . . . . . . . . . . . . . . .16 Reconnect the Lower . . . . . . . . . . . . . . . . . . . . .17 Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 Dura-Flo Pumps with NXT Air Motors . . . . . . . . 18 Dura-Flo Pumps with Viscount Hydraulic Motors 20 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 Mounting Hole Layouts . . . . . . . . . . . . . . . . . . . . .23 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 GracoStandardWarranty . . . . . . . . . . . . . . . . . . .28 GracoInformation . . . . . . . . . . . . . . . . . . . . . . . . .28 311826B Models Models Dura-Flo Pumps with NXT™ Air Motors Check your pump’s identification plate (ID) for the 6-digit part number of your pump. Use the following matrix to define the construction of your pump, based on the six digits. For example, Pump Part No. P15MCD represents the ID pump (P), pressure ratio (15 :1), low noise exhaust motor with DataTrak™ (M), carbon steel construction (C), and 3 ptfe/2 leather packing configuration (D). To order replacement parts, see Parts section starting on page 18. The digits in the matrix do not correspond to the Ref. Nos. in the Parts drawings and lists. P 1 5 M C D First Digit Second and Third Digit Fourth Digit Fifth Digit Sixth Digit Pressure Ratio (xx:1) Exhaust Communication Material Packings 12 D De-Icing none C Carbon Steel A 3 uhmwpe/2 ptfe P (pumps) 15 E De-Icing DataTrak S Stainless Steel B 3 uhmwpe/2 Tuff-Stack™ 23 L Low Noise none D 3 ptfe/2 leather 32 M Low Noise DataTrak Pump Part No. and Series Lower Part No. Lower Model, Packings Air Motor Part No. Ratio Maximum Working Pressure MPa, bar (psi) Maximum Air Input Pressure MPa, bar (psi) P12LCD, A 222801 Dura-Flo 2400 (580 cc) cst, 3 PTFE/2 leather N34LN0 12:1 8.2, 82 (1190) 0.7, 7.0 (100) P12LSA, A 222803 Dura-Flo 2400 (580 cc) sst, 3 UHMWPE/2 PTFE N34LN0 12:1 8.2, 82 (1190) 0.7, 7.0 (100) P12MCD, A 222801 Dura-Flo 2400 (580 cc) cst, 3 PTFE/2 leather N34LT0 12:1 8.2, 82 (1190) 0.7, 7.0 (100) P12MSA, A 222803 Dura-Flo 2400 (580 cc) sst, 3 UHMWPE/2 PTFE N34LT0 12:1 8.2, 82 (1190) 0.7, 7.0 (100) P12DSA, A 222803 Dura-Flo 2400 (580 cc) sst, 3 UHMWPE/2 PTFE N34DN0 12:1 8.2, 82 (1190) 0.7, 7.0 (100) P12ESA, A 222803 Dura-Flo 2400 (580 cc) sst, 3 UHMWPE/2 PTFE N34DT0 12:1 8.2, 82 (1190) 0.7, 7.0 (100) P12DCD, A 222801 Dura-Flo 2400 (580 cc) cst, 3 PTFE/2 leather N34DN0 12:1 8.2, 82 (1190) 0.7, 7.0 (100) P12ECD, A 222801 Dura-Flo 2400 (580 cc) cst, 3 PTFE/2 leather N34DT0 12:1 8.2, 82 (1190) 0.7, 7.0 (100) Continued on page 4. 311826B Models Pump Part No. and Series Lower Part No. Lower Model, Packings Air Motor Part No. Ratio Maximum Working Pressure MPa, bar (psi) Maximum Air Input Pressure MPa, bar (psi) P15LCD, A 222796 Dura-Flo 1800 (430 cc) cst, 3 PTFE/2 leather N34LN0 15:1 10.9, 109 (1580) 0.7, 7.0 (100) P15LSB, A 687055 Dura-Flo 1800 (430 cc) sst, 3 UHMWPE/2 PTFE N34LN0 15:1 10.9, 109 (1580) 0.7, 7.0 (100) P15MCD, A 222796 Dura-Flo 1800 (430 cc) cst, 3 PTFE/2 leather N34LT0 15:1 10.9, 109 (1580) 0.7, ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias