Log:
Assessments - 3, GPA: 3.3 ( )

Instruções de Operação Hitachi, Modelo 222104

Fabricante : Hitachi
Arquivo Tamanho: 208.56 kb
Arquivo Nome : 307906v.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


180 psi (1.2 MPa, 12.4 bar) Maximum Air and Fluid Working Pressure Oil Pumps Model No. 222051, Series E Universal Pump Model No. 222103, Series E 55-Gallon Drum, Bung-Mount Pump Model No. 222104, Series E 275-Gallon Tank, Bung-Mount Pump 307906V CAUTION These pumps are designed to pump lubricating fluids only. Models 222103 222104 Model 222051 05939B 05940B Important Safety instructions Read all warnings and instructions in this manual. Save these instructions. See page 2 for Table of Contents. Table of Contents Symbols Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Parts Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Dimensional Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Performance Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Graco Standard Warranty . . . . . . . . . . . . . . . . . . . . . . 16 Graco Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Warning Symbol WARNING This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions. Caution Symbol CAUTION This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions. WARNING EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury. . This equipment is for professional use only. . Read all instruction manuals, tags, and labels before you operate the equipment. . Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor. . Do not alter or modify this equipment. Use only genuine Graco parts and accessories. . Check equipment daily. Repair or replace worn or damaged parts immediately. . Do not exceed the maximum working pressure of the lowest rated component in your system. This equipment has a 180 psi (1.2 MPa, 12.4 bar) maximum working pressure at 180 psi (1.2 MPa, 12.4 bar) maximum incoming air pressure. . Use fluids and solvents that are compatible with the equipment wetted parts. Refer to the Technical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings. . Do not use 1,1,1–trichloroethane, methylene chloride, other halogenated hydrocarbon solvents, or fluids that contain such solvents in pressurized aluminum equipment. Such use could result in a chemical reaction, with the possibility of explosion. . Handle hoses carefully. Do not pull on hoses to move equipment. . Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses to temperatures above 82C (180F) or below –40C (–40F). . Do not lift pressurized equipment. . Comply with all applicable local, state, and national fire, electrical, and safety regulations. 2 307906 WARNING SKIN INJECTION HAZARD Fluid from the dispensing valve, leaks, or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury. . If a fluid injection injury occurs, get immediate surgical treatment. Do not treat as a simple cut. Tell the doctor exactly what fluid was injected. . Do not point the dispensing valve at anyone or at any part of the body. . Do not put your hand or fingers over the end of the dispensing valve. . Do not stop or deflect leaks with your hand, body, glove, or rag. . Use only extensions and no-drip tips that are designed for use with your dispensing valve. . Do not use a low pressure flexible nozzle with this equipment. . Follow the Pressure Relief Procedure on page 8 if the dispensing valve clogs before you clean, check, or service the equipment. . Tighten all fluid connections before you operate the equipment. . Check the hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. Do not repair high pressure couplings; you must replace the entire hose. TOXIC FLUID HAZARD Hazardous fluids or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed. . Know the specific hazards of the fluid you are using. . Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state and national guidelines. . Always wear protective eyewear, gloves, clothing, and respirator as recommended by the fluid and solvent manufacturer. 307906 3 WARNING WARNING FIRE AND EXP...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias