Log:
Assessments - 1, GPA: 5 ( )

Instruções de Operação Harbor Freight Tools, Modelo 95386

Fabricante : Harbor Freight Tools
Arquivo Tamanho: 1.78 mb
Arquivo Nome : 95386.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


and well-lit. The work area must not allow access by children or pets to prevent injury. Locate the Compressor on a flat 2. level surface to ensure proper pump lubrication and to prevent damage to the unit. Keep at least 12” of space around the unit to allow air circulation. Route the power cord from the 3. compressor to the grounded wall outlet, along a safe path without creating a tripping hazard or exposing the power cord to possible damage. Assembly Attaching the Foot and Wheels To attach the Foot (66) to the front 1. bottom of the Air Tank (1): Using the Bolt/Washer/Nut Assembly a. (67), slide a flat washer onto the Bolt. Slide the Bolt through the Foot and b. the hole in the Air Tank front leg. Slide a flat washer and the lock c. washer onto the bolt and secure in place with the nut. To attach the Wheels (5) to the back 2. bottom of the Air Tank (1): Slide the Wheel Shaft Bolt (6) a. through the Wheel (5), a Flat Washer (4), and the hole in the leg of the Air Tank. Slide the remaining Flat Washer (4) b. and Lock Washer (3) onto the Wheel Shaft Bolt and secure in place with the Nut (2). Repeat step (a) and (b) for the other c. Wheel. Installing the Air Filter Figure 2Cylinder Head (46)Air Filter (45) Thread the Air Filter (45) clockwise onto the side of the Cylinder Head (46). Set up Quick CouplerSample Air Line SetupRegulator with Pressure GaugeQuick CouplerAir Hose on ReelShut OffValveFilterOilerCoupler PlugToolAir CompressorCoupler PlugFigure 4 1. Connect a 1/4” NPT air hose to the Quick Coupler (all sold separately). The air hose must be long enough to reach the work area with enough extra length to allow free movement while working. Depending on the tool which you will 2. be using with this compressor, you may need to incorporate additional components, such as an in-line oiler, a filter, or a dryer (all sold separately). Consult your air tool’s manual for needed accessories. Checking the Oil IMPORTANT: Running the Air Compressor with no oil or low oil will cause damage to the equipment and void the warranty. Oil Sight Glass (33) Crankcase Cover (32) overfilllowfullOIL LEVELFigure 5 1. The oil level should be at the center of the “full” level on the Oil Sight Glass (33), as shown in Figure 5. Add oil as needed to maintain this level. Do not let the oil level go below the center dot (LOW as shown in Figure 5) and do not overfill the oil so that it is above the center dot (OVERFILL as shown in Figure 5) on the sight glass. To add oil:2. Unthread the Oil Plug (31).a. Using a funnel to avoid spills, b. pour enough premium quality SAE 30-weight, non-detergent, air compressor oil (sold separately) into the Pump Crankcase to reach the “full” level in the Oil Sight Glass. Replace the Oil Plug.c. If uncertain which oil to use for this 3. compressor, please call Harbor Freight Tools customer service at 1-800-444-3353 for assistance. Change the compressor oil after 4. the first hour of use to remove any debris. WARNING! To prevent serious injury from burns: Do not add or change the oil while the compressor is in operation. Allow the compressor to cool before replacing oil. Initial run of the Air Compressor Break in the new Air Compressor as 5. follows: Check the oil level (See Checking a. the Oil). Make sure the Power Button is OFF b. and the unit is unplugged. Insert a male coupler (sold separately) into the female Quick Coupler and fully open all regulators and valves. Plug in the Power Cord.c. Turn the Power Switch ON.d. Let the unit run for 30 minutes. Air e. will expel freely through the Coupler. Turn the Power Button OFF.f. Unplug the Power Cord and remove g. the male coupler. General Operating Instructions Read the entire Important Safety Information section at the beginning of this manual including all text under subheadings therein before set up or use of this product. Close the Drain Valve (65) by turning 1. it counterclockwise. Make sure all nuts and bolts are tight.2. Check for oil leaks and check the oil 3. level (See Checking the Oil). Close the in-line Shutoff Valve 4. between the compressor and the air hose. Make sure the air tool’s throttle or 5. switch is in the off position. Connect the air tool to the air hose. 6. Plug the Air Compressor Power Cord 7. into a grounded 120 V electrical outlet. Open the in-line Shutoff Valve.8. Turn the compressor ON by pulling 9. up on the On/Off Power Button. Allow the Air Compressor to build up 10. pressure until it cycles off. Note: At the beginning of the day’s first use of the Air Compressor, check for air leaks by applying soapy water to connections while the Air Compressor is pumping and after pressure cut-out. Look for air bubbles. If air bubbles are present at connections, tighten connections. Do not use the air compressor unless all connections are air tight, the extra air leaking out will cause the compressor to operate too often, increasing wear on the compressor. Note: As long as the Power Button is ON, the operation of the Air Compressor is aut...

Este manual também é adequado para os modelos :
equipamento de bombagem - CENTRAL PNEAMATIC 95386 (1.78 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias