|
Facilidade de uso
Continue washing area until medical help is available. If the utility pump is used on a boat, turn 13. off the boat ignition before making power cord (1) connections. If used on a boat, always connect the 14. red power cord (1) on the utility pump to the positive (+) side of the boat’s 12 volt DC electrical system. Connect the 15. black power cord (1) on the utility pump to the negative (--) side of the boat’s 12 volt electrical system. When connecting the power cords (1) to 16. the boat’s 12 volt DC electrical system, connect the red power cord first. Then, connect the black power cord. When disconnecting the power cords from the electrical system, disconnect the black power cord first. Then, disconnect the red power cord. Turn the boat’s ignition switch to its “off” 17. position and disconnect the utility pump from the boat’s 12 volt DC electrical system before performing any inspection, adjustments, maintenance, or cleaning procedures on the pump. Do not submerge the utility 18. pump in water. People with pacemakers should consult 19. their physician(s) before using this product. Electromagnetic fields in close proximity to a heart pacemaker could cause interference to or failure of the pacemaker. SPECIFICATIONS Model 9576 94639 Motor 12 VDC / 50 W / 4,500 RPM 12 VDC / 110 W / 4,500 RPM Application Utility Water Pumping, including marine applications Utility Water Pumping Power Wires 18 AWG x 19” Long (Qty. 2) Discharge Height* 23 ft. Flow Rate* 200 GPH 300 GPH Self Priming Yes Construction Stainless Steel Pump Housing Steel Motor Housing Dual Threaded Inlet 3/8”-18 NPT Female I.D. 3/4” Male O.D. Dimensions 5-3/4” L x 2-1/2” Dia. x 4” H *Note: For optimal performance, the suction hose (not included) I.D. must be at least the same size as the suction flange and free of air leaks. All joints and connections of the suction hose should be securely tightened to prevent air from entering the suction side. Use a good grade suction hose that will not collapse. In addition, the height from the inlet to the pump and then the height from the outlet to the discharge will greatly impact pump performance. UNPACKING When unpacking, make sure the item is intact and undamaged. If any parts are missing or broken, please call Harbor Freight Tools at 1-800-444-3353 as soon as possible. OPERATING INSTRUCTIONS NOTE: For additional reference to the parts mentioned in the following pages, refer to the Assembly Diagram at the end of this manual. NOTE: Mount the pump permanently to a flat surface only. Do not mount the Pump on a rounded surface. (Hardware for permanently mounting the Utility Pump is not included.) CONNECTSUCTION HOSE(NOT INCLUDED) HERE. CONNECTDISCHARGE HOSE(NOT INCLUDED) HERE. FIGURE A 1. The Inlet and Outlet Ports on the Utility Pump are both dual threaded with an Inside Diameter of 3/8” NPT and an Outside Diameter of 3/4”. This allows for more versatility in selecting a suction hose and discharge hose (not included) with the proper threaded male or female connector. (See Figure A.) If you are connecting a suction hose 2. having a threaded male connector, wrap about 4” of pipe seal tape (not included) around the threads of the male connector. Then, firmly screw the male connector into the threaded female connector of the Utility Pump. Repeat REV 08e, 10a this process for the discharge hose having a threaded male connector. If you are connecting a suction hose 3. having a threaded female connector, wrap about 4” of pipe seal tape (not included) around the threads of the male connector of the Utility Pump. Then, firmly screw the female connector of the suction hose onto the threaded male connector of the Utility Pump. Repeat this process for the discharge hose having a threaded female connector. Note: Depending on the make/model of boat on which the Utility Pump will be used, there are many variations as to connecting the Utility Pump to the boat’s 12 Volt DC electrical system. Therefore, it is recommended that only a qualified technician perform this procedure. Note: It is highly recommended that a circuit protection device and control switch be used when permanently installing this pump. Refer to the section, “Specific Product Warnings and Precautions” in this manual for further instructions. INSPECTION, MAINTENANCE, AND CLEANING TO PREVENT INJURY AND FIRE FROM ACCIDENTAL OPERATION OR SPARKING: Turn the Boat’s Ignition Switch to its “OFF” position and disconnect the Power Cords (1) from the boat’s 12 Volt DC electrical system before performing any inspection, maintenance, or cleaning. BEFORE EACH USE,1. inspect the general condition of the Utility Pump. Check for loose screws, misalignment or binding of moving parts, cracked or broken parts, damaged electrical wiring, loose or leaking suction and discharge hoses, and any other condition that may affect the safe and efficient operation of the Utility Pump. If abnormal noise or vibration occurs, have the problem corrected before further use. Do not use damaged eq...
Este manual também é adequado para os modelos :equipamento de bombagem - 9576 (761.4 kb)