|
Facilidade de uso
1 - Typical 2 Cylinder Water-Cooled Condensing Unit (07DA102, Single-Phase Illustrated) Carrier INSTALLATION 06D,07D DISCHARGE , DISCHARGE MANIFOLD DISCHARGE MUFFLER GAGE CONN.~~----.--_ / PRESSURESTAT CONN.__„ TERMINAL BLOCK SUCTION PRESSURESTAT CONNECTION-—-S COMPRESSOR NAMEPLATE suction shut-off ^run valve capacitors SUCTION GAGE TART C0NN APACITORS PUMP END BEARING HEAD OIL PUMP COVER BULL'S EYE - m OIL DRAIN PLUG- WATER OUTLET . ......................................................mum............................ (COOLING TOWER ONLY) «BfflrolKuiMWM ;ontrol BOX ...............................■ 'CONDENSING UNIT FUSIBLE UNION _ ^ NAMEPLATE (USE FOR WARRANTY PURPOSES) ' I;S-™1 ° ^ 'REFRIGERANT TAG WATER INLET \ NAMEPLATE (COOLING TOWER) \ MOUNTING WATER INLET \ WATER SPRINGS (REMOVE AND OUTLET \ REGULATING VALVE BOLTS BEFORE STARTING) (CITY WATER) N LIQUID LINE CONN. PRESSURE CONN Fig. 2 - Typical 4 Cylinder Water-Cooled Condensing Unit (07DA103, Single-Phase Illustrated) DISCHARGE GAGE CONN. DISCHARGE SHUT-OFF VALVE SUCTION MANIFOLD PRESSURESTAT CONN. PUMP END BEARING HEAD OIL PUMP COVER BULL’S EYE OIL DRAIN PLUG PURGE COCK WATER OUTLET (COOLING TOWER ONLY) FUSIBLE UNION WATER INLET (COOLING TOWER) WATER INLET AND OUTLET (CITY WATER DISCHARGE MUFFLER DISCHARGE MANIFOLD PRESSURESTAT CONN. -TERMINAL BLOCK REFRIGERANT TAG CONTROL BOX 'LIQUID LINE CONN. ■WATER REGULATING VALVE PRESSURE CONN. SUCTION SHUT-OFF VALVE COMPRESSOR NAMEPLATE CONDENSING UNIT NAMEPLATE (USE FOR WARRANTY PURPOSES) MOUNTING SPRINGS (REMOVE BOLTS BEFORE STARTING) Fig. 3 - Typical 4 Cylinder Water-Cooled Condensing Unit (07DA106, Three-Phase Illustrated) 3 06D,07D INSTALLATION (Carrier) DISCHARGE GAGE CONN. DISCHARGE SHUT-OFF VALVE DISCHARGE MANIFOLD PRESSURESTAT CONN. PUMP END BEARING HEAD OIL PUMP COVER BULL'S EYE WATER INLET AND OUTLET HEADERS (SEE FIG 18 FOR PROPER CONNECTIONS) DISCHARGE MUFFLER SUCTION MANIFOLD PRES5URESTAT CONN TERMINAL BLOCK SUCTION SHUT-OFF VALVE CONTROL BOX REFRIGERANT TAG COMPRESSOR NAMEPLATE CONDENSING UNIT NAMEPLATE OIL FILL PLUG MOUNTING SPRINGS (REMOVE BOLTS BEFORE STARTING) LIQUID LEVEL TEST COCK LIQUID LINE CONN. ' WATER REGULATING VALVE PRESSURE CONN Fig. 4 - Typical 6 Cylinder Water-Cooled Condensing Unit (07DA210, Three-Phase Illustrated) CAPACITY CONTROL SOLENOID VALVES DISCHARGE SHUT-OFF VALVE DISCHARGE GAGE CONNECTION PUMP END BEARING HEAD OIL PUMP COVER OIL FILL PLUG BULL'S EYE OIL DRAIN PLUG DISCHARGE MUFFLER WATER INLET AND OUTLET HEADERS (SEE FIG. 18 FOR PROPER CONNECTIONS) LIQUID LINE CONNECTION FUSIBLE UNION (HIDDEN) ' LIQUID LEVEL TEST COCK MOUNTING SPRINGS (REMOVE BOLTS BEFORE STARTING) WATER REGULATING VALVE PRESSURE CONN Fig. 5 - Typical 6 Cylinder Water-Cooled Condensing Unit - Capacity Control (07DA215, Three-Phase Illustrated) 4 NOTES 1. NET WEIGHT INCLUDES OIL BUT NOT REFRIG. CHARGE. 2. OIL PUMP IS AUTOMATICALLY REVERSIBLE FOR EITHER DIRECTION OF ROTATION 3. CONTROL BOX DRAWING 06D-20I-EI 4. MUFFLER DRAWING ' 06D- 202-4 YES NO LIQUID STRAINER-DRIER 1^^ CRANKCASE HEATER PKG. _ _ UNIT MODEL NET WEIGHT (LBS) A D E 07DAI02 181 2‘-5|' 07DA203 190 2-7 C 3 4;" Dimensions are approximate. Certified dimension drawings are available on request. Fig. 6 - Dimensions for 07DA102 and 07DA203 9^) INSTALLATION 06D,07D NOTES' 1. NET WEIGHT INCLUDES OIL BUT NOT REFRIG. CHARGE. 2. OIL PUMP IS AUTOMATICALLY REVERSIBLE FOR EITHER DIRECTION OF ROTATION. 3. CONTROL BOX DRAWING! 06D-20I-EI 4. MUFFLER DRAWING ' OGD- 202-4 YES NO LlQUlU STRAINER-DRIER CRANKCASE HEATER PKG. UNIT MODEL NET WEIGHT (LBS) A c 0 E F 1 G H J K L M W MPT X FPT • 07DAI03 247 2-9" I'-iis" 1-4" 5" 8 i-o" 4|" 6" 4" 5 " 8 l’-2-L" 3 " 4 1 " 07DA106 294 2'-9|" 2-44 6" ■V i'-i" K3" elM 7" 8 i-7” ! 1“ 2 07DA208 330 3'-3|" I-IO" 7" °4 I 3" 4 Dimensions are approximate. Certified dimension drawings are available on request. Fig. 7 - Dimensions for 07DA103,106 and 208 06D/07D INSTALLATION (Carrier # NOTES 1. NET WEIGHT INCLUDES OIL BUT NOT REFRIG. CHARGE. 2. OIL PUMP IS AUTOMATICALLY REVERSIBLE FOR EITHER DIRECTION OF ROTATION. 3. CONTROL BOX DRAWING 06D-20I-EI 4. MUFFLER DRAWING 06D-202-4 YES NO PRESS. ACTUATED CONTROL VALVE(S) _ LIQUID STRAINER- DRIER _ _ CRANKCASE HEATER PKG. _ _ UNIT MODEL CAPACITY CONTROL NET WEIGHT (LBS) 07 D A 210 WITHOUT 475 07DB2I0 WITH g ODF DISCHARGE VALVE ■k FPT DISCHARGE GAGE CONN.-, OIL LEVEL SIGHT GLASS^jj” I T ODF SUCTION VALVE SUCTION GAGE CONN. WATER OUTLET CONN (I )8(2) CIRCUIT WATER INLET CONN. (I ) CIRCUIT CAP FOR (2) CIRCUITS fFLARE CONN. FUSIBLE UNION WATER INLET (21CIRCUITS CAP FOR (I ) CIRCUIT COIL DRAIN LIQUID SHUT-OFF VALVE Dimensions are approximate. Certified dimension drawings are available on request. Fig. 8 - Dimensions for 07DA210 and 07DB210 INSTALLATION 06D,07D NOTES. 1. NET WEIGHT INCLUDES OIL BUT NOT REFRIG. CHARGE. 2. OIL PUMP IS AUTOMATIC...
Este manual também é adequado para os modelos :equipamento de bombagem - 07D (1.76 mb)