Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação Campbell Hausfeld, Modelo FP209699DQL

Fabricante : Campbell Hausfeld
Arquivo Tamanho: 841.67 kb
Arquivo Nome :
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


END OF OPERATION/STORAGE 1. Turn ON / OFF switch to the OFF position. 2. Unplug power cord from wall outlet and wrap around handle area to prevent damage when not in use. 3. Wearing safety glasses drain tank of air by pulling the ring on the safety valve. Use other hand to deflect fast moving air from being directed toward your face. 4. Drain tank of condensation by opening drain valve on bottom of tank. Tank pressure should be below 10 psi when draining tank. 5. Air hose should be disconnected from compressor and hung open ends down to allow any moisture to drain. 6. Compressor and hose should be stored in a cool, dry place. Figure 6 4 FP209501, FP209598, FP209599, FP209601, FP209699DB, and FP209699DQ Notes 5 Oilless Compressors Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Compressor will not run 1. Switch in OFF position 2. No electrical power at wall outlet 3. Compressor has reached automatic shut-off pressure 4. Motor overheated 1. Make sure compressor is plugged in and switch is ON 2. Check circuit breaker or fuse at electrical panel. 3. Release air from tank until compressor restarts automatically 4. Allow compressor to cool for approximately 30 minutes so thermal overload switch will reset. Make 5. Loose electrical connection sure compressor is run in a clean, well-ventilated area where temperature will not exceed 100°F. 5. Check all electrical connections 6. ON / OFF switch bad 7. Pressure switch bad 8. Defective motor 6. Replace ON / OFF switch 7. Replace pressure switch 8. Replace pump / motor assembly Thermal overload 1. Lack of proper ventilation/room 1. Move compressor to a clean,well ventilated area protector cuts out temperature too high where temperature will not exceed 100°F. repeatedly 2. Excessive air usage, compressor too 2. Decrease usage or purchase unit with higher air small delivery (SCFM) Tank pressure drops 1. Open tank drain valve when compressor shuts 2. Loose connections (fittings, tubing, off air hose, any connections, etc.) 3. Tank leaks 1. Close tank drain valve 2. Check all connections with soap and water solution. If a leak is detected, tighten. Or remove fitting and apply pipe tape to threads and reassemble. Do not disassemble check valve. With air in tank, bleed tank first. 3. Check entire tank for leaks with soap and water solution. Compressor runs 1. Excessive air usage, compressor too continuously / air small output lower than 2. Open tank drain valve normal 3. Loose connections (fittings, tubing, air hose, any connections, etc.) 4. Pump wore out 1. Decrease usage or purchase unit with higher air delivery (SCFM) 2. Close tank drain valve 3. Check all connections with soap and water solution. If a leak is detected, tighten. Or remove fitting and apply pipe tape to threads and reassemble. 4. Replace pump / motor assembly Excessive moisture in discharge air 1. Excessive water in tank 2. High humidity 1. Drain tank, tilt tank to remove moisture 2. Move to area of less humidity; use air line filter Safety valve pops open 1. Defective pressure switch 2. Defective safety valve 1. Replace pressure switch 2. Replace safety valve with genuine replacement part 6 FP209501, FP209598, FP209599, FP209601, FP209699DB, and FP209699DQ For Replacement Parts or Please provide following information: Address parts correspondence to: -Model number Attn: Customer Service Technical Assistance, - Serial number (if any) 100 Production Drive -Part description and number as Harrison, OH 45030 U.S.A. Call 1-800-543-6400 shown in parts list 1 2 7 24 9 10 12 13 17 18 19 22 20 14 3 11 16 5 6A 6 4 21 25 23 8 26 27 28 32 31 29 15 30 33 30 Ref. Ref. No. Description Part Number Qty. No. Description Part Number Qty. Replacement Parts List 34 35 31 1 Shroud . 1 22 Accessories FP204008AV 1 2 Shroud insert . 1 23 25' Recoil Hose MP268100AV 1 3 4 On/off switch M3x15 screw FP204824AV . 1 4 24 25 Plastic base Pressure switch tube kit ^ FP209535AV 1 1 5 Manifold assembly FP209527AV 1 26 Cap (see part #10) 1 6 2 in. Diameter gauge FP209529AV 1 27 Spring (see part #10) 1 6A 1.5 in. Diameter gauge FP209528AV 1 28 Tank — 1 7 Safety valve V-215102AV 1 29 Screw Ў 2 8 Motor isolator bushing kit FP209037AV 1 30 Washe...

Este manual também é adequado para os modelos :
equipamento de bombagem - FP209501 (841.67 kb)
equipamento de bombagem - FP209699DB (841.67 kb)
equipamento de bombagem - FP209598 (841.67 kb)
equipamento de bombagem - FP209599 (841.67 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias