Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação Porter-Cable, Modelo N028591

Fabricante : Porter-Cable
Arquivo Tamanho: 2.67 mb
Arquivo Nome :
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


7. Torque 3/8" lag screws to 7-10 ft.-lbs (9.5-13.5 Nm). WIRING INSTRUCTIONS Improper electrical installation of this product may void its warranty and your fire insurance. Have circuit wiring performed by qualified personnel such as a licensed electrician who is familiar with the current national electrical code and any prevailing local electrical codes. Risk of electrical shock. Improper electrical grounding can result in electrical shock. The wiring should be done by a qualified electrician. A qualified electrician needs to knows the following before wiring: 1. The amperage rating of the electrical box should be adequate. Refer to the Specifications, in the parts manual, for this information. 2. The supply line should have the same electrical characteristics (voltage, cycle, phase) as the motor. Refer to the motor nameplate, on side of motor, for this information. NOTE: The wiring must be the same as the motor nameplate voltage plus or minus 10%. Refer to local codes for recommended wire sizes, correct wire size, and maximum wire run; undersize wire causes high amp draw and overheating to the motor. Risk of electrical shock. Electrical wiring must be located away from hot surfaces such as manifold assembly, compressor outlet tubes, heads, or cylinders. GROUNDING INSTRUCTIONS This product should be connected to a metallic, permanent wiring system, of an equipment-grounding terminal or lead on the product. VOLTAGE AND CIRCUIT PROTECTION Refer to the Specifications for the voltage and minimum branch circuit requirements. Certain air compressors can be operated on a 15 amp circuit if the following conditions are met. 1. Voltage supply to circuit must comply with the National Electrical Code. 2. Circuit is not used to supply any other electrical needs. 3. Extension cords comply with specifications. 4. Circuit is equipped with a 15 amp circuit breaker or 15 amp time delay fuse. NOTE: If compressor is connected to a circuit protected by fuses, use only time delay fuses. Time delay fuses should be marked "D" in Canada and "T" in the US. If any of the above conditions cannot be met, or if operation of the compressor repeatedly causes interruption of the power, it may be necessary to operate it from a 20 amp circuit. It is not necessary to change the cord set. AIR DISTRIBUTION SYSTEM Risk of bursting. Plastic or PVC pipe is not designed for use with compressed air. Regardless of its indicated pressure rating, plastic pipe can burst from air pressure. Use only metal pipe for air distribution lines. The next figure represents a typical air distribution system. The following are tips to remember when setting up the air compressor’s air distribution system. 9 - ENG 10 - ENG SPRAY GUN AIR TOOL DRAIN LEGS FILTER / MOISTURE TRAP DIRT LEGS DRAIN VALVES DRAIN VALVE LUBRICATOR REGULATOR GLOBE VALVE / AIR DISCHARGE VALVE MAIN DISTRIBUTION AIR LINES Slope pipe in direction of air flow. Water condensate flows along bottom of pipe to drain legs, preventing it from entering feeder lines. REGULATOR BALL FILTER FLEXIBLE COUPLING DRAIN VALVE TYPICAL COMPRESSED AIR DISTRIBUTION SYSTEM AIR FLOW AIR FLOW FEEDER LINES SLOPE WITH AIR FLOW AIR USAGE LINES AIR COMPRESSOR FILTER / MOISTURE TRAP FOR BEST PERFORMANCE the distance between the compressor and the moisture trap should be as long as possible RISK OF BURSTING. ALWAYS USE METAL PIPING AND FITTINGS. DRAIN VALVES 5 MICRON FILTER .01 MICRON FILTER NOTE: Compressed air from oil lube air compressors will contain water condensation and oil mist. Several drains, traps and filters will be needed to supply air without water (including aerosols) or oil to spray equipment, air tools and accessories requiring filtered air. Always read the instructions for the air tools and accessories being used. • Use pipe that is the same size as the air tank outlet. Piping that is too small will restrict the flow of air. • If piping is over 100' (30.5 m) long, use the next larger size. • Bury underground lines below the frost line and avoid pockets where condensation can gather and freeze. Apply pressure before underground lines are covered to make sure all pipe joints are free of leaks. • A flexible coupling is recommended to be installed between the globe valve/ air discharge outlet and main air distribution line to allow for vibration. • A separate regulator is recommended to control the air pressure. Air pressure from the tank is usually to high for individual air driven tools. • DO NOT install lubricators between the tank and any spray equipment, air tool or accessory requiring oil-free filtered air. • Drain all traps, filters and dirt legs daily. OPERATION OPERATION kNOW YOUR AIR COMPRESSOR READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Auto(I)/Off(O) Switch Safety Valve Tank Pressure Gauge Pressure Switch DESCRIPTION OF O...

Este manual também é adequado para os modelos :
equipamento de bombagem - C7501 (2.67 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias