Facilidade de uso


Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o’clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence. J P210 H CRSEPC »WER REQUIREM S 1- Z E RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 250 0.26 0.2 0.3 0.4 0.4 500 0.51 0.4 0.5 0.7 0.9 1000 1.03 0.7 1.1 1.4 1.8 1750 1.80 1.2 1.9 2.5 3.1 3000 2.87 2.0 3.0 4.0 5.0 3200 3.06 2.1 3.2 4.2 5.3 3450 3.30 2.3 3.4 4.6 5.7 intermittent duty only HORSEPOWER RATINGS: The rating shown are the power requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above. We recommend a 1.15 service factor be specified when selecting an electric motor as the power source. To compute specific pump horse power requirements, use the following formula: HP = (GPM X PSI) / 1450 8 Specifications Model P211 1750 RPM+...................................................................................................U. .S. Metric Flow (Continuous) @ 2000 PSI (140 Bar)..........2.1 GPM.......................7.9 L/min Flow (Intermittent) @ 2500 PSI (175 Bar) .........2.1 GPM.......................7.9 L/min 3450 RPM+ Flow (Continuous) @ 2000 PSI (140 Bar)..........3.8 GPM.......................14.4 L/min Flow (Intermittent) @ 2000 PSI (140 Bar) .........3.8 GPM.......................14.4 L/min Maximum Inlet Pressure .....................................145 PSI.........................10 Bar Plunger Diameter.................................................0.47”.............................12 mm Stroke...................................................................0.56”.............................14.2 mm Max. Temperature of Pumped Fluids..................160o F............................70o C Inlet Ports....................................................................................................(2) 1/2" BSP Discharge Ports........................................................................................... (2) 3/8" BSP Shaft Rotation......................................................Top of Pulley Towards Fluid End Crankshaft Diameter............................................0.98”.............................24 mm Key Width...........................................................0.31”.............................8 mm Shaft Mounting....................................................Right Side Facing Manifold Weight.................................................................11.7 lbs.........................5.3 Kg Crankcase Oil Capacity.......................................7.5 fl.oz........................0.22 Liters Extended Crankcase Oil Capacity.......................9.0 fl.oz........................0.27 Liters Volumetric Efficiency @ 1750 RPM.........................................................0.94 Volumetric Efficiency @ 3450 RPM.........................................................0.87 Mechanical Efficiency @ 3450 RPM.........................................................0.86 +Positive inlet pressure required Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above. D NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o’clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence. P211 H CRSEPC »WER REQUIREM HENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 500 0.60 0.4 0.6 0.8 1.0 1000 1.20 0.8 1.2 1.7 2.1 1750 2.10 1.4 2.2 2.9 3.6 3000 3.30 2.3 3.4 4.6 5.7 3200 3.52 2.4 3.6 4.9 6.1 3450 3.80 2.6 3.9 5.2 6.5 intermittent duty only HORSEPOWER RATINGS: The rating shown are the power requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above. We recommend a 1.15 service factor be specified when selecting an electricmotor as the power source. To compute specific pump horse power requirements, use the following formula: 9 HP = (GPM X PSI) / 1450 Exploded View - P205/P206/P207/P208/P209/P210/P211 1 2 3 3 3A 3B 4 5 5A 6 6A 7 8 9 10 11 12A 121 13 13 13 13 13 13 13 1 3 3 3 3 3 3 3 3 3 3 1 6 6 6 6 6 6 6 6 8 1 1 1 1 P205/P206/P207/P208/P209/P210/P211 PARTS LIST PART NO. DESCRIPTION QTY. ITEM PART NO. DESCRIPTION 08300 Crankcase 1 14 06207 Woodruff Key 06773 Oil Dipstick with O-Ring 1 15 08333 Connecting Rod 08302 Crankcase Cover, Short 1 16 06641 Plunger, Complete, 12mm 08302-L Crankcase Cover, Long 1 17 08442 Wrist Pin 07190 Drain Plug 1 19 0 01 0 - 6 5 3 8 0 Oil Seal 13262 Gasket f...

Este manual também é adequado para os modelos :
equipamento de bombagem - P205 (211.62 kb)
equipamento de bombagem - P206 (211.62 kb)
equipamento de bombagem - P207 (211.62 kb)
equipamento de bombagem - P208 (211.62 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias