Log:
Assessments - 2, GPA: 3 ( )

Instruções de Operação TriStar, Modelo SP3010EEAZ

Fabricante : TriStar
Arquivo Tamanho: 314.32 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


- Dual suction fittings shall be placed in such locations and distances to avoid “dual blockage” by a user. - Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas. - The maximum system flow rate shall not exceed the values shown in the “Pipe Sizing Chart” found at the bottom of page 5 of this manual. - Never use pool or spa if any suction outlet component is damaged, broken, cracked, missing, or not securely attached. - Replace damaged, broken, cracked, missing, or not securely attached suction outlet components immediately. - In addition to two or more suction outlets per pump installed in accordance with latest IAF (formerly NSPI) standards and CPSC guidelines, follow all national, state, and local codes applicable. - Installation of a vacuum release or vent system, which relieves entrapping suction, is recommended. TriStar™ Pump Series __________ _____ ______________________________ Page 4 of 15 WARNING – Hazardous Pressure. Pool and spa water circulation systems operate under hazardous pressure during start-up, normal operation, and after pump shut-off. Stand clear of circulation system equipment during pump start-up. Failure to follow safety and operation instructions could result in violent separation of the pump housing and cover due to pressure in the system, which could cause property damage, severe personal injury, or death. Before servicing pool and spa water circulation system, all system and pump controls must be in off position and filter manual air relief valve must be in open position. Before starting system pump, all system valves must be set in a position to allow system water to return back to the pool. Do not change filter control valve position while system pump is running. Before starting system pump, fully open filter manual air relief valve. Do not close filter manual air relief valve until a steady stream of water (not air or air and water mix) is discharged from the valve. All suction and discharge valves MUST be OPEN when starting the circulation system. Failure to do so could result in severe personal injury and/or property damage. WARNING – Separation Hazard. Failure to follow safety and operation instructions could result in violent separation of pump components. Strainer cover must be properly secured to pump housing with strainer cover lock ring. Before servicing pool and spa circulation system, all system and pump controls must be in off position and filter manual air relief valve must be in open position. Do not operate pool and spa circulation system if a system component is not assembled properly, damaged, or missing. Do not operate pool and spa circulation system unless filter air relief valve body is in locked position in filter upper body. All suction and discharge valves MUST be OPEN when starting the circulation system. Failure to do so could result in severe personal injury and/or property damage. WARNING – Never operate or test the circulation system at more than 50 PSI. WARNING – Fire and burn hazard. Motors operate at high temperatures and if they are not properly isolated from any flammable structures or foreign debris they can cause fires, which may cause severe personal injury or death. It is also necessary to allow the motor to cool for at least 20 minutes prior to maintenance to minimize the risk for burns. WARNING – Failure to install according to defined instructions may result in severe personal injury or death. General Information Introduction This manual contains information for the proper installation and operation of the Hayward TriStar Pump Series. The instructions in this manual MUST be followed precisely. Failure to install according to defined instructions will void warranty. Product Benefits The new TriStar Pump’s advanced fluid dynamic design optimizes the three essential pump elements to deliver superior flow, energy efficiency, and quietness. Plus, the heavy-duty pump and motor construction operates cooler for years of dependability. It is the first to feature a Tri-Lock cam...

Este manual também é adequado para os modelos :
equipamento de bombagem - SP3007EEAZ (314.32 kb)
equipamento de bombagem - SP3007X10AZ (314.32 kb)
equipamento de bombagem - SP3010X15AZ (314.32 kb)
equipamento de bombagem - SP3015EEAZ (314.32 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias