Log:
Assessments - 4, GPA: 3.8 ( )

Instruções de Operação DeVillbiss Air Power Company, Modelo WB100D-2

Fabricante : DeVillbiss Air Power Company
Arquivo Tamanho: 88.5 kb
Arquivo Nome : 9e59ae4d-b5f7-4eaf-9118-6cf371f26c2f.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


The grounding wire has insulation with an outer surface that is green - with or without yellow stripes. If these grounding instructions are not completely understood, or if in doubt as to whether the compres sor is properly grounded, have the installation checked by a qualified electrician. 120 Volts, 15 Amps 120 Volt Models Air Hose The air hose attached to your compressor has an integral pressure adjusting valve at the working end of the hose. Should service or replacement be required, make sure that the pressure adjusting valve is present in the air hose line. It is normal for the adjustable pressure valve to release air during operation. DO NOT REPLACE THE HOSE WITH STANDARD HOSE THAT IS NOT EQUIPPED WITH THE PRESSURE ADJUSTING VALVE. THE APPROPRIATE HOSE ASSEMBLY FOR YOUR COMPRESSOR IS AVAILABLE AT SEARS. Do not allow hose to become kinked or pinched at any time. This is important to avoid damage to your compressor and to maintain pressure adjusting valve control. OPERATING PROCEDURES 1. Before plugging in the air compressor, set the adjustable pressure valve to "10" PSI. Make sure the "ON/ OFF" switch is in the "OFF" position. 2. Connect the air tool or accessory to the air hose. Tighten securely. 3. Plug the power cord into the grounded outlet. 4. Start the compressor by setting the "ON/OFF" switch to the "ON" position. TOO MUCH AIR PRESSURE COULD CAUSE AN AIR TOOL OR VEHICLE TIRE TO RUPTURE OR EXPLODE. CAREFULLY FOLLOW STEPS 5 AND 6 EACH TIME YOU USE YOUR COMPRESSOR. 5. Check the manufacturer's maximum pressure rating for the air tool, accessory or vehicle tire being used. The air compressor outlet pressure must never exceed the maximum pressure rating. 6. Slowly increase the pressure setting of the adjustable pressure valve. You should be able to hear and feel air pressure being relieved by the adjustable pressure valve. If pressure is not being relieved, turn the air compressor off immediately. The pressure valve must be replaced. Compressed air from the outfit may contain water condensation. Do not spray unfiltered air at an item that could be damaged by moisture. Some air operated tools or devices may require filtered air. Read the instructions for the air tool or device. 7 — ENG STORAGE When you have finished using the air compressor: 1. Set the "ON/OFF" switch to "OFF" and unplug the 3. Protect the electrical cord and air hose from damage cord. by winding them loosely around the air compressor. 2. Relieve all pressure from the air compressor head 4. Store the air compressor in a clean and dry location. and air hose by setting the adjustable pressure valve to 10 P.S.I. 8 — ENG AIR COMPRESSOR DIAGRAM Pressure Valve Assembly ON/OFF SWITCH PARTS AVAILABLE FOR THIS UNIT DESCRIPTION PART NUMBER Pressure Valve Assembly.......................CAC-4324 Connecting Rod Kit ................................KK-4926 Fastener Kit ............................................KK-4929 Isolator Kit...............................................KK-4930 9 — ENG TROUBLESHOOTING GUIDE VOLTAGE SOURCES, MOVING PARTS OR COMPRESSED AIR SOURCES ARE EXPOSED WHEN REPAIRING THE COMPRESSOR. PERSONAL INJURY CAN OCCUR. UNPLUG THE COMPRESSOR BEFORE ATTEMPTING ANY REPAIRS. PROBLEM CAUSE CORRECTION Air Leaks Hose fitting loose. Tighten fitting. Compressor is not delivering enough air. Prolonged excessive use of air. Hole in hose. Air leaks. Decrease the amount of air usage. Your compressor is not large enough for the air requirement. Replace the hose. Tighten fittings. Motor will not run. Fuse blown, circuit breaker tripped. Extension cord is wrong length or gauge. Loose electrical connections. Faulty motor. 1. Check fuse box for blown fuse and replace as necesssary. Reset circuit breaker. Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit. 2. Check for proper fuse. You should be using a Quick Acting fuse. 3. Check for low voltage problem. 4. Check the extension cord. 5. Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit. Check the extension cord. Check wiring connection inside terminal box Have checked at a local Service Center. High discharge pressure. Cannot be adjusted lower. Adjustable pressure valve not functioning. RISK OF BURSTING. DO NOT OPERATE THE COMPRESSOR IF THIS PROBLEM EXISTS. ADJUSTABLE PRESSURE VALVE MUST BE REPLACED. 10 — ENG SERVICE NOTES 11 — ENG OWNERS MANUAL FOR PERMANENTLY LUBRICATED AIR COMPRESSOR MODEL NOS. WB100D-2 — XE-7D-2 — IRC1D-2 (For Home Use Only) Call our Toll Free Number 1-800-888-2468, Ext 2, then 1, to obtain the location of the nearest Authorized Service Center for ordering repair parts and for warranty repairs. When ordering repair parts from your local Authorized Service Center, always give the following information: • Model number of your product • Part number and description of the item you wish to purchase WARRANTY Attach Sales Receipt Here. This product is covered by the De...

Este manual também é adequado para os modelos :
equipamento de bombagem - MGP-XE-WB-C1D (88.5 kb)
equipamento de bombagem - SP-100-E (88.5 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias