Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação Dimplex, Modelo LA 6MR

Fabricante : Dimplex
Arquivo Tamanho: 3.69 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


In this context, particular attention must be paid to the proper disposal of refrigerants and refrigeration oils. 10 APPENDIX 12 12 APPENDIX 12.1 DIMENSIONED DRAWING 12 12.2 EQUIPMENT DATA 13 12.3 SCHEMATICS 12.3.1 Heating mode LA 6MR 14 12.3.2 Cooling mode LA 6MR 15 12.3.3 Heating mode LA 8MR 16 12.3.4 Cooling mode LA 8MR 17 12.3.5 Heating mode LA 10MR 18 12.3.6 Cooling mode LA 10MR 19 12.3.7 Heating mode LA 12TR 20 12.3.8 Cooling mode LA 12TR 21 12.3.9 Heating mode LA 16TR 22 12.3.10 Cooling mode LA 16TR 23 12.4 WIRING DIAGRAMS 12.4.1 Control LA 6MR-LA 10MR 24 12.4.2 Load LA 6MR-LA 10MR 25 12.4.3 Terminal Diagram LA 6MR-LA 10MR 26 12.4.4 Legend LA 6MR-LA 10MR 27 12.4.5 Control LA 12TR-LA 16TR 28 12.4.6 Load LA 12TR-LA 16TR 29 12.4.7 Terminal Diagram LA 12TR-LA 16TR 30 12.4.8 Legend LA 12TR-LA 16TR 31 12.5 HYDRAULIC BLOCK DIAGRAMS 12.5.1 Mono-energetic system 32 12.5.2 Mono-energetic system and domestic hot water function 33 12.6 EC DECLARATION OF CONFORMITY 34 11 12 Dimensioned Drawing APPENDIX: 12.1 DIMENSIONED DRAWING 35 (circumferential) Electr. connection box (inspection side) Air discharge end Condensate drain Condensate drain Condensate pan Condensate tube (plastic) Soil to sewer ( Base frame ) Feed-through Electric lines Heating water Return G 1” external thread Heating water Supply G 1” external thread Direction of air flow Appliance contact surfaces (stainless steel) APPENDIX: 12.2 EQUIPMENT DATA Equipment Data EQUIPMENT DATA for air-to-water heat pumps for heating 1 TYPE AND COMMERCIAL DESCRIPTION LA06MRN LA08MRN LA10MRN LA12TRN LA16TRN 2 MODEL 2.1 Type reversible reversible reversible reversible reversible 2.2 Enclosure type acc. to EN 60 529 for compact unit and/or heating element IP 24 IP 24 IP 24 IP 24 IP 24 2.3 Installation site outdoors outdoors outdoors outdoors outdoors 3 PERFORMANCE DATA 3.1 Operating temperature limits: Heating water supply / return °C / °C Cooling, flow °C Air (heating) °C Air (cooling) °C max.60/min.18 +7 to +20 -20 to +35 +15 to +45 max.60/min.18 +7 to +20 -20 to +35 +15 to +45 max.60/min.18 +7 to +20 -20 to +35 +15 to +45 max.60/min.18 +7 to +20 -20 to +35 +15 to +45 max.60/min.18 +7 to +20 -20 to +35 +15 to +40 3.2 Heating capacity / coeff. of perform. at A7 / W35 1) kW / --at A7 / W45 1) kW / --6.1 / 3.3 6.1 / 2.7 7.4 / 3.3 7.3 / 2.7 8.5 / 3.4 8.4 / 2.8 11.9 / 3.3 11.6 / 2.7 15.3 / 3.3 14.9 / 2.8 3.3 Cooling capacity / coeff. of perform. at A35 / W18 kW / --at A35 / W7 kW / --7.9 / 3.2 6.4 / 2.7 9.4 / 3.3 7.7 / 2.9 11.1 / 3.3 9.0 / 2.9 15.8 / 3.3 13.6 / 3.0 18.5 / 3.3 16.1 / 3.0 3.4 Sound power level dB(A) 70 71 71 72 72 3.5 Sound pressure level at 10 m distance (discharge side) dB(A) 45 46 46 47 47 3.6 Heating water flow rate m./h 1.1 1.3 1.5 1.7 1.9 3.7 Free pressure, heating circulating pump (max. stage) Pa 34800 35600 33800 32700 58900 3.8 Refrigerant; total charge weight type / kg R407C / 1.5 R407C / 2.3 R407C / 2.3 R407C / 3.4 R407C / 3.7 3.9 Rating electric heating element (back-up heater) max. kW 6 6 6 6 6 4 DIMENSIONS; CONNECTIONS AND WEIGHT 4.1 Equipment dimensions H x W x L cm 86 x 127 x 67 86 x 127 x 67 86 x 127 x 67 86 x 127 x 67 86 x 127 x 67 4.2 Equipment connections for heating inch G 1'' external G 1'' external G 1'' external G 1'' external G 1'' external 4.3 Weight of transport unit(s) incl. packaging kg 159 165 170 185 196 5 ELECTRICAL CONNECTION 5.1 Nominal voltage; fusing V / A 230 / 20 230 / 20 230 / 25 400 / 20 400 / 25 5.2 Fuse protection, electric heating element (only 230V units) A 30 4) 30 4) 30 4) -- 5.3 Nominal power consumption 1) A2 W35 kW 1.9 2.3 2.5 3.6 4.6 5.4 Starting current with soft starter A 26 32 38 26 27 5.5 Nominal current A2 W35 / cos . A / --10.3 12.5 13.6 6.5 8.3 6 COMPLIES WITH EUROPEAN SAFETY REGULATIONS 3) 3) 3) 3) 3) 7 OTHER DESIGN CHARACTERISTICS 7.1 Defrosting Defrost type Defrost pan available automatic cycle reversal yes (heated) automatic cycle reversal yes (heated) automatic cycle reversal yes (heated) automatic cycle reversal yes (heated) automatic cycle reversal yes (heated) 7.2 Heating water inside unit protected against freezing yes 2) yes 2) yes 2) yes 2) yes 2) 7.3 Performance settings 1 1 1 1 1 1) 2) The heating circulating pump and the controller of the heat pump must be on standby at all times. 3) See EC Declaration of Conformity 4) For the electr. connection of the electric heating element, a separate load line with its own fuse protection is required. Subject to change without notice Issued: 02.03.2006 These data characterize the size and performance of the system. For economic and energetic considerations, additional factors such as defrosting behaviour, bivalence point and control need to be taken into account. Abbreviations have the following meaning: e.g. A7 / W35: outside temperature 7 °C and heating water supply temperature 35 °C. 13 APPENDIX: 12.3 SCHEMATICS 12.3.1 Heating mode LA 6MR 0 1 2 3 4 5 6 7 8 9 10 11 -20 -10 0 10 20 30 40 35 50 0 1 2 3 -20 -10 0 10 20 30 40 50 35 40 0 1 2 3 4 5 6 -...

Este manual também é adequado para os modelos :
equipamento de bombagem - LA 10MR (3.69 mb)
equipamento de bombagem - LA 12TR (3.69 mb)
equipamento de bombagem - LA 16TR (3.69 mb)
equipamento de bombagem - LA 8MR (3.69 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias