Instruções de Operação Dimplex, Modelo SI 17CS

Fabricante : Dimplex
Arquivo Tamanho: 1.19 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


immersion heater, hot water E10* Suppl. heating system (boiler or electr. heating element) F2 Load fuse for N1 relay outputs across J12 and J13 4.0 A slow F3 Load fuse for N1 relay outputs across J15 to J18 4.0 A slow F4 Pressostat high pressure F5 Pressostat low pressure (in SI 17CS, F5 is a limiter with manual reset) F15* Motor protection M11, from SI 9CS to SI 17CS integrated in primary pump H5* Lamp, remote fault indicator J1...J18 Terminal connector at N1 K1 Contactor, compressor K5 Contactor, primary pump K11* Electron. relay for remote fault indicator (relay module) K12* Electron. relay for swimming pool water circulating pump K20* Contactor, suppl. heating system K21* Contactor, electr. immersion heater, hot water K22* Utility company disable contactor K23* SPR auxiliary contactor M1 Compressor M11* Primary pump M13* Heating circulating pump M15* Heating circulating pump for heating circuit 2 M16* Suppl. circulating pump M18* Hot water circulating pump M19* Swimming pool circulating pump M21* Mixer heating circuit 1 M22* Mixer heating circuit 2 N1 Heat pump controller N7 Soft start control (not fitted in SI 5CS and SI 7CS appliances) N10* Remote control station N11* Relay module R1 External sensor R2 Return sensor R3 Hot water sensor (as an alternative to hot water thermostat) R5 Sensor for heating circuit 2 R6 Freeze protection sensor R7 Coding resistor 8k T1 Safety isolating transformer 230/24V AC-28V A X1 Terminal strip mains control L/N/PE-230V AC-50 Hz/fuses/N and PE-terminal block X2 Terminal strip 24V AC-terminal block X3 Terminal strip GND terminal block for sensors R1/-2 and -3 at J2 X4 Terminal stripGND terminal blocl for sensors R5 and -6 at J6 X5 Terminal strip power supply 3 L/PE-400V AC-50 Hz Abbreviations: EVS Utility company disable input SPR Supplementary disable input MA* Mixer OPEN MZ Mixer CLOSED *Components to be supplied by the customer 32 33 12.4.5 Control .. 21CS APPENDIX: 12.4 WIRING DIAGRAMS 0 VAC C 7 Q2 F12 J1-G0 230 VAC - 50Hz L 230 VAC 24 VAC T1 1 2 p o l . 1 2 p o l . Netz X1 3 N PE 4 , 0 A T r F3 4 , 0 A T r F2 M1 M2 11 11 14 14 Q1 J18-C13 C 1 X2-G X3 B 2 J2 R2 24VAC 0 VAC B 1 J1 J5-IDC1 G G 0 R7 B C 5 B 3 J3 + V D C G N D B C 4 B 5 B 4 J9 J10 J11 N1 Verdi. J12 N O 3 F2 (L) K1.2 -A1 C 1 V1 V2 N O 1 N O 2 J1-G V G J4 V G 0 Y 1 Y 4 Y 3 Y 2 1 Sto.-M1 X2 A2 24VAC Sto.-M11 2 ID C 1 A1 ID 1 EVS SPR ID 8 J5 ID 7 ID 6 ID 3 ID 2 ID 4 ID 5 C 4 K5-A1 J13 N O 5 N O 4 N O 6 C 4 F3 (L) F14-T1 F4 A1 A2 T2 T1 F14 K1.2 K1.1 K1 K5 A1 A2 A1 A2 16 18 K1.2 15 A2 A1 0 VAC J5-IDC1 F5 P < N O 1 2 B 8 X4 R6 EGS J6 B 7 J12-C1 B 6 J14-C7 G N D J7 ID 1 0 ID 1 1 ID 1 2 ID C 9 ID 9 N O 9 C 9 J14 N O 7 J15 N O 8 N C 8 C 7 C 8 J16 N O 1 0 N O 1 1 C 9 M1 J12/NO1 P > HD ND J8 ID 1 3 H ID C 1 3 ID 1 4 H ID 1 3 ID 1 4 M11 J12/NO3 C 1 2 J17 J18 N C 1 3 N O 1 3 N C 1 2 C 1 3 F4 F5 J13-C4 J12-C1 Mains system 34 12.4.6 Load .. 21CS APPENDIX: 12.4 WIRING DIAGRAMS M2 W T M1 3 M F12 1 U V 2 -/1.5 X5 3/PE 400VAC - 50Hz Netz 3 1 3 K1.1 R S 2 4 L1 L2 PE L3 F14/1.5 M1 N7 M11 3 M Q2 5 6 K1 2 4 6 I > I > I > 14 11 12 / 1.5 X1 PE 1 3 5 Q1 12 / 1.4 K5 2 4 6 I > I > I > 14 11 1 3 5 Mains system 35 12.4.7 Terminal Diagram .. 21CS APPENDIX: 12.4 WIRING DIAGRAMS 230 VAC - 50Hz F3 PE ID 8 4, 0 A Tr F2 (L) K5-A1 F3 (L) B C 5 X3 R1 R2 B 1 G G 0 J1 N1 J9 J10 R3 R7 B 5 J2 B 2 J11 + V D C B C 4 G N D B 3 B 4 J3 J12 Kontakt offen = WP gesperrt Die Funktion des 2ten WE ist wahlbar EVU-Sperrschutz T< V G 0 V G Y 1 Y 4 Y 3 Y 2 J13 J4 SPR EVS T< ID 7 ID 6 ID 3 ID 2 ID 1 ID 4 ID 5 J5 C 1 N O 1 N O 2 N O 3 K1.2 -A1 C 1 Verdi. V1 V2 3L/PE 400VAC - 50Hz Netz L X5 2 L 1 L 3 4 P E xxxxx N10 M11 2 C 4 N O 5 N O 4 N O 6 C 4 -PE -N X1 -N X1 X1 X1 -PE -N HK H e i z s t a b oder E10 M13 Netz 3 12 pol . 12 pol . X1 N M18 0 VAC J1-G0 Kontakt offen = WP gesperrt 24VAC 2ter Sperreingang B 7 J6 X2 0 VAC R5 J14 J1-G0 ID C 1 B 6 J15 J1-G X4 4 P < 2 1 B2 ID C 9 B 8 ID 1 0 ID 1 1 ID 1 2 G N D ID 9 J16 J7 J18 ID 1 3 H ID C 1 3 ID 1 4 H ID 1 3 ID 1 4 J17 J8 -PE -N E9 4, 0 A Tr 4 3 C 7 N O 7 N O 8 N C 8 C 7 C 8 -PE -N MA -PE -N X1 MZ F2 N O 9 N O 1 0 N O 1 1 C 9 C 9 X1 -N X1 L X1 3 M16 2 3 4 C 1 3 N O 1 3 N O 1 2 N C 1 2 C 1 2 -PE X1 MAN MZN -N N C 1 3 3 M15 K20 M21 K21 M22 B3 B4 K11 K12 T 1 L 1 max. 200W A 2 ( - ) A 1 ( + ) J 1 3 - C 4 L 1 T 1 M19 A 1 ( + ) A 2 ( - ) J 1 4 - C 7 H5 max. 200W N11 X1 - N K22 K23 Mains system Mains system 230 VAC - 50 Hz Utility company disable contactor Contact open = HP disabled The function of the suppl. heating system can be selected 2nd disable input Contact open = HP disabled APPENDIX: 12.4 WIRING DIAGRAMS 12.4.8 Legend .. 21CS A1 Wire jumper, must be removed if a utility company disable contactor is used A2 Wire jumper, must be removed if 2nd disable input is used B2* Pressostat low pressure, brine B3* Thermostat, hot water B4* Thermostat, swimming pool water E9* Electr. immersion heater, hot water E10* Suppl. heating system (boiler or electr. heating element) F2 Load fuse for N1 relay outputs across J12 and J13 4.0 A...

Este manual também é adequado para os modelos :
equipamento de bombagem - SI 11CS (1.19 mb)
equipamento de bombagem - SI 14CS (1.19 mb)
equipamento de bombagem - SI 21CS (1.19 mb)
equipamento de bombagem - SI 5CS (1.19 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias