Log:
Assessments - 3, GPA: 4.7 ( )

Instruções de Operação Ducane (HVAC), Modelo 2HP14

Fabricante : Ducane (HVAC)
Arquivo Tamanho: 763.13 kb
Arquivo Nome : d2hp14bl-100.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


See limited warranty document for details. B Model 2HP14 Split System Heat Pump seer 14 2 HP 14 B 36 P - 1 A Model Number Guide Refrigerant – 2 = R22 AC = Condenser HP = Heat Pump 14 - 14 SEER Nominal Family / Coil Protection B = Non-Louvered L = Louvered A = Service Level Revision Code Voltage P - 208-230v/60hz Single Phase Nominal Capacity 36 - 36,000 Btuh Model Voltage/ Hz/ Phase Voltage Range Min. Circuit Amp. Maximum Over Current Device (amps) Compressor Fan Motor Refrig. Charge (oz.): Weight (lbs.) Rated Load (Amps) Locked Rotor (Amps) Full Load Amps Rated HP Nom. RPM Wire Guard/ Louvered 2HP14*18P 208-230/60/1 197 - 253 11.1 20 8.3 41 0.7 1/10 1075 139 162/174 2HP14*24P 208-230/60/1 197 - 253 14.6 25 10.3 56 0.7 1/10 1075 131 175/187 2HP14*30P 208-230/60/1 197 - 253 16.0 25 12.2 61 0.8 1/5 1075 160 187/200 2HP14*36P 208-230/60/1 197 - 253 18.4 30 13.5 73 0.8 1/5 1075 177 195/208 2HP14*42P 208-230/60/1 197 - 253 22.2 35 16.5 95 1.4 1/4 1075 188 222/239 2HP14*48P 208-230/60/1 197 - 253 23.7 40 18.0 104 1.4 1/4 1075 273 224/241 2HP14*60P 208-230/60/1 197 - 253 26.0 40 19.2 137 2.0 1/3 1075 252 275/292 Electrical and Physical Data * = B, L Dimensions (in.) and Sound Ratings Model Dimensions B, L Sound Rating (dBa) A - width (in.) B - depth (in.) C - height (in.) 2HP14*18P 30-3/4 30-3/4 25.5 78 2HP14*24P 30-3/4 30-3/4 25.5 79 2HP14*30P 30-3/4 30-3/4 29.5 79 2HP14*36P 30-3/4 30-3/4 29.5 79 2HP14*42P 30-3/4 30-3/4 41.5 78 2HP14*48P 30-3/4 30-3/4 41.5 78 2HP14*60P 30-3/4 30-3/4 41.5 78 * = B, L 2HPP144 SSppliitt Systeemm HeatPPummpp 1144ss eeeerr Cooling Performance with Evaporator Coils Outdoor Model Indoor Model Cooling Heating Refrigerant Connection Refrigerant Line Size Indoor Metering Device Piston or Field Installed TXV Factory Installed TXV Outdoor Indoor SuctionLiquidReq'd Indoor2 Orifice Optional Field Installed OrificeSEER EER Rated ARI Capacity1 Rated Sensible Capacity HSPF 47° 17° CFM SuctionLiquidSuctionLiquidBtuh COP Btuh COP 2HP14*24P E(C,H,M,U)1P29NA E(C,H,M,U)2T29NA 14.00 12.50 24,000 18,500 8.20 22,400 3.40 14,400 2.24 850 3/4 3/8 3/4 3/8 3/4 3/8 --H2TXV01 2HP14*30P E(C,H,M,U)1P36N(A,B,C)+TXV E(C,H,M,U)2T36N(A,B,C) 13.50 12.00 28,400 23,200 7.70 26,000 2.94 18,400 2.26 1050 3/4 3/8 3/4 3/8 3/4 3/8 --H2TXV01 E(C,H,M,U)1P43NB+TXV E(C,H,M,U)2T43NB 13.50 12.00 29,000 23,600 7.70 26,000 2.94 18,200 2.24 1050 3/4 3/8 7/8 3/8 3/4 3/8 --H2TXV01 E(C,M,U)1P48N(B,C)+TXV E(C,M,U)2T48N(B,C) 13.50 12.00 28,800 23,500 7.70 26,000 2.90 18,000 2.22 1050 3/4 3/8 7/8 3/8 3/4 3/8 --H2TXV01 2HP14*48P E(C,H,U)1P49NC+TXV E(C,H,U)2T49NC+TXV 14.00 11.50 47,000 38,700 8.20 45,500 3.60 26,400 2.18 1700 7/8 3/8 7/8 3/8 7/8 3/8 --H2TXV02 E(C,M,U)1P62ND+TXV E(C,H,U)2T62ND 14.00 11.50 47,000 38,700 8.20 45,500 3.60 26,400 2.20 1700 7/8 3/8 7/8 3/8 7/8 3/8 --H2TXV02 2HP14*60P E(C,H,U)1P62NC+TXV E(C,H,U)2T62NC 13.00 12.00 53,000 44,000 7.70 52,000 3.30 32,000 2.30 1950 7/8 3/8 7/8 3/8 1-1/8 3/8 --H2TXV02 E(C,H,U)1P62ND+TXV E(C,H,U)2T62ND 13.00 12.00 53,000 44,000 7.70 52,000 3.30 32,000 2.30 1950 7/8 3/8 7/8 3/8 1-1/8 3/8 --H2TXV02 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on ARI Standard 210/240. 2 Required to achieve ARI rating. A blower time delay is required to achieve ARI rating. * = B, L 2HP14SplitSystemHeatPumpseer14 seer14 Cooling Performance with Air Handlers and Furnaces 18, 24, 30 Outdoor Model Indoor Model Furnace Cooling Heating Refrigerant Connection Refrigerant Line Size Indoor Metering Device Piston or Field Installed TXV Factory Installed TXV Outdoor Indoor SuctionLiquidReq'd Indoor2 Orifice Optional Field Installed OrificeSEER EER Rated ARI Rated Sensible Capacity HSPF 47° 17° CFM SuctionLiquidSuctionLiquidBtuh COP Btuh COP 2HP14*18P E(C,H,M,U)1P29NA+TVX E(C,H,M,U)2T29NA CMPEV050,075 15.00 13.50 19,000 15,200 7.70 17,300 3.64 9,500 2.18 650 3/4 3/8 3/4 3/8 3/4 3/8 --H2TXV01 E(C,H,M,U)1P29NA+TVX E(C,H,M,U)2T29NA MPGAV050,075 15.00 13.50 19,000 15,200 8.00 17,300 3.64 9,500 2.20 650 3/4 3/8 3/4 3/8 3/4 3/8 --H2TXV01 E(C,H,M,U)1P36NA+TVX E(C,H,M,U)2T36NA CMPEV050,075 15.00 13.50 19,000 15,200 7.70 17,300 3.64 9,500 2.20 650 3/4 3/8 3/4 3/8 3/4 3/8 --H2TXV01 E(C,H,M,U)1P36NA+TVX E(C,H,M,U)2T36NA MPGAV050,075 15.00 13.50 19,000 15,200 8.00 17,300 3.64 9,500 2.20 650 3/4 3/8 3/4 3/8 3/4 3/8 --H2TXV01 RBCS2M18C*****P+TXV RBCS2M18C*****T ----14.00 12.50 19,000 15,200 7.70 17,300 3.50 9,500 2.12 650 3/4 3/8 3/4 3/8 3/4 3/8 --H2TXV01 RBCS2M24V*****P+TXV -------- 15.00 14.00 19,000 15,200 8.10 17,000 3.70 9,200 2.10 650 3/4 3/8 3/4 3/8 3/4 3/8 --H2TXV01 2HP14*24P E(C,H,M,U)1P29NA+TVX E(C,H,M,U)2T29NA CMPEV050,075 14.00 12.50 24,000 18,500 8.20 22,400 3.40 14,400 2.24 850 3/4 3/8 3/4 3/8 3/4 3/8 --H2TXV01 E(C,H,M,U)1P29NA+TVX E(C,H,M,U)2T29NA MPGAV050,075 14.00 12.50 24,000 18,500 8.20 22,400 3.40 14,200 2.24 850 3/4 3/8 3/4 3/8 3/4 3/8 --H2TXV01 E(C,H,M,U)1P36NA+TVX E(C,H,M,U)2T36NA CMPEV050,075 14.00 12.50 24,000 18,500 8.20 22,400 3.40 14,400 2.24 850 3/4 3/8 3/4 ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias