Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação RIDGID, Modelo OL90150

Fabricante : RIDGID
Arquivo Tamanho: 1.4 mb
Arquivo Nome : 386349ce-33b9-455e-b477-2af427bf9295.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


If power disconnect point is out-of-sight, lock it in the open position and tag to prevent unexpected application of power. 12. Guard all moving parts; keep visitors away. Never allow children in work area. 13. Use only a properly grounded outlet that will accept a three pronged plug, and wear shoes to prevent shock hazards. 14. Be careful when touching exterior of operating motor; it may be hot enough to cause injury. 15. Protect power cable from coming in contact with sharp objects. 16. Clean electrical or electronic equipment with an approved cleaning agent, such as dry, nonflammable cleaning solvent. 17. To avoid spontaneous combustion, discard waste rags into approved metal waste cans. 18. Never store flammable liquids or gases in vicinity of compressor. 19. When spraying with solvent or toxic chemicals, follow instructions provided by the chemical manufacturer. 20. Spray in a well ventilated area, to keep fumes from collecting and causing health and fire hazards. 21. Do not spray in vicinity of open flames or other places where a spark can cause ignition. Do not smoke when spraying paint, insecticides, or other flammable substances. 22. Use a respirator when spraying. 23. NEVER reset safety valve or pressure switch. Keep safety valve free from paint and other accumulations. This provides safety against over pressure. 24. Do regular maintenance; keep all nuts, bolts, and screws tight, to be sure equipment is in safe working condition . 25. Keep cleaning rags and other flammable waste materials in a tightly closed metal container and dispose of later in the proper fashion. 26. Drain tanks of moisture after each day’s use. If unit will not be used for a while, it is best to leave drain cock open until such time as it is to be used. This will allow moisture to completely drain out and help prevent corrosion of inside of tank. 27. Inspect tank yearly for rust, pin holes or any other imperfections that could cause it to become unsafe. NEVER weld or drill holes in air tank. 28. Do not wear loose clothing or jewelry that will get caught in the moving parts of the unit. 4 Spraying Precautions Do not spray flamma- ble materials in vicin- ity of open flame or near ignition sources including the compressor unit. ! WARNING: 1. Do not smoke when spraying paint, insecticides, or other flammable substances. 2. Use a face mask/respirator when spraying and spray in a well ventilated area to prevent health and fire hazards. 3. Do not direct paint or other sprayed material at the compressor. Locate compressor as far away from the spraying area as possible to minimize overspray accumulation on the compressor. 4. When spraying or cleaning with solvents or toxic chemicals, follow the instructions provided by the chemical manufacturer. ! DANGER: Breathable Air Warning This compressor/pump is not equipped and should not be used “as is” to supply breathing quality air. For any application of air for human consumption, the air compressor/pump will need to be fitted with suitable in-line safety and alarm equipment. This additional equipment is necessary to properly filter and purify the air to meet minimal specifications for Grade D breathing as described in Compressed Gas Association Commodity Specification G 7.1 - 1966, OSHA 29 CFR 1910. 134, and/or Canadian Standards Associations (CSA). DISCLAIMER OF WARRANTIES In the event the compressor is used for the purpose of breathing air application and proper in-line safety and alarm equipment is not simultaneously used, existing warranties shall be voided, and Campbell Hausfeld disclaims any liability whatsoever for any loss, personal injury or damage. 5 Safety Instructions (continued) 6 Find and read all warning labels found on the air compressor shown below Warning Labels DK724100AV 1000 Motor Specifications and Electrical Requirements Power Supply and Motor Specifications ! WARNING: To reduce the risk of electrical hazards, fire hazards or damage to the tool, use proper circuit protection. Your tool is wired at the factory for operation using the voltage shown. Connect tool to a power line with the appropriate voltage and a 15amp branch circuit. Use a 15amp time delay type fuse or circuit breaker. To reduce the risk of shock or fire, if power cord is worn or cut, or damaged in any way, have it replaced immediately. The A-C motor used on this compressor is a capacitor start, capacitor run nonreversible induction type, having the following specifications. It is wired at the factory for operation on 110V-120V AC, 60 Hz service. Voltage 110-120 220-240 Amperes 15.0 7.5 Hertz (Cycles) 60 Phase Single RPM 3450 General Electrical Connections ! DANGER: To reduce the risk of electrocution: 1. Use only identical replacement parts when servicing. Servicing should be performed by a qualified technician. 2. Do not use in rain or where floor is wet. This tool is intended for indoor residential use only. ! WARNING: Do not permit fingers to touch the terminals of plug when installing or removing...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias