Log:
Assessments - 3, GPA: 4.3 ( )

Instruções de Operação Pentax, Modelo R-335EX(NX)

Fabricante : Pentax
Arquivo Tamanho: 1.2 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


However, there is a possibility including some errors in this case, so be sure to select the reflectorless mode. • The target constant should be correctly selected and confirmed in case that the reflector sheet is used at the prism mode and the prism is used at the reflector sheet mode. 6.2 Distance measurement H.angle H.dst. V.dst. SHOT ( ( ( ) ) ) MEAS TARGET 0 SET DISP MODE MODE A 15°C S 0 92° 30’ 20” The R-300X series has two distance measurement modes of primary MEAS and second MEAS. Pressing the [F1] [MEAS] one time goes to MEAS and twice goes to second MEAS. You can freely select and allocate your desired measurement mode in primary MEAS and second MEAS by the Initial Setting 2. The “MEASURE SHOT” is set at primary MEAS and “TRACK CONT” is set at second MEAS as a Factory default setting. • MEASURE SHOT means the distance measurement by the shot mode. • MEASURE CONT means the distance measurement by the continuous mode. • TRACK SHOT means the fast distance measurement by the shot mode. • TRACK CONT means the fast distance measurement by the continuous mode. Confirm the target constant before beginning the distance measurement. Example:“MEASURE SHOT”at primary MEAS (Factory default setting) Collimate the telescope at a target and press the [F1] [MEAS] once to start measuring the distance. Once distance measurement has been started, the distance measurement mark remains displayed. Upon reception of a reflected light from the target, the instrument beeps and displays the • mark to start the shot measurement automatically. • If the instrument is in mode B, press the [F5] [MODE] to switch to mode A and press [F1] [MEAS]. • Pressing the [F1] [MEAS] after collimating the telescope at the prism starts shot distance measurement with the “MEAS” text blinking. Distance measurement is completed and the “MEAS” text stops blinking the moment the distance measured by shot measurement is displayed. During continuous measurement, the “MEAS” text keeps on blinking. Pressing the [F1] [MEAS] again terminates both distance measurement and blinking the “MEAS” text. • Pressing [F4] [DISP] cycles through the sets of display items:“H.angle/H.dst./V.dst.”, “H.angle/V.angle/S.dst.”, and “H.angle/V.angle/H.dst./S.dst./V.dst.” • Pressing the [ESC] or [F2] [TARGET] or [F5] [MODE] during distance measurement stops it. • If the shot count for distance measurement has been set to 2 or more in “Initial Setting 2", the distance is measured for the specified number of times to display the averaged value. • If the automatic distance measurement: [AUTO MEAS] in “Initial Setting 2” has been set to “MEAS” the first measurement is started only by aiming at the Target. Press [F1] [MEAS] for each measurement after the first one. • If the automatic distance signal: [MEAS SIGNAL] in “Initial Setting 2” has been set to VALUE, a two-digit number representing the AIM value appears as soon as measurement starts (The AIM value varies depending on the distance and atmospheric conditions.) • The minimum distance unit : [MEAN. MIN DISP] COARSE or FINE can be selected by the initial setting 2. Example:“TRACK CONT”at second MEAS (Factory default setting) Collimate the telescope at a Target and press [F1] [MEAS] twice in succession to start measuring the distance, upon reception of a reflected light from the target, the instrument beeps and displays the _ mark to start the TRACK distance measurement. H.angle H.dst. V.dst. CONT ( ( ( ) ) ) MEAS TARGET 0 SET DISP MODE MODE A 15°C S 0 92° 30’ 20” • If the instrument is in mode B, press [F5] [MODE] to switch to mode A and press [F1] [MEAS ] twice. • Pressing [F1] [MEAS] twice after collimating the telescope at the Target starts Continuous distance measurement at fast speed with the “MEAS” text blinking. It remains blinking during the measurement. If you press the [F1] [MEAS] again, Distance measurement is completed and the “MEAS” text stops blinking. • Pressing [F4] [DISP] cycles through the sets of display items:“H.angle/H.dst./V.dst.”, “H.angle/V.angle/S.dst.”, and “H.angle/V.angle/H.dst./S.dst./V.dst.” • Pressing the [ESC] or [F2] [TARGET] or [F5] [MODE] during fast distance measurement stops it. 6.3 Quick mode The Quick Mode is to shorten the measuring time using prism or reflector sheet. • The Quick Mode is effective to measure the distance up to 500M using prism or reflector sheet. • After selecting Quick Mode from the Quick Mode setting screen, the distance measurement is done in Quick Mode. • If the quick mode is selected, the distance measurement mark, "<-<-->->", instead of "((( )))", is displayed H.angle H.dst. V.dst. CONT MEAS TARGET 0 SET DISP MODE MODE A 15°C S 0 92° 30’ 20” 7. CORRECTION MODE 7.1 Changing the target constant Changing the Target Constant can be performed only when the Reflector sheet and Prism Constant settings are “INPUT” in Initial Setting 1. Example: Prism Constant - 25mm setting Press [F4] [CORR] in mode B. (If the instrument is in mode A, press [F5] [MODE] to enter mode B.) ...

Este manual também é adequado para os modelos :
Instrumentos ópticos - R-315EX(NX) (1.2 mb)
Instrumentos ópticos - R-315EX(NX) (1.2 mb)
Instrumentos ópticos - R-322EX(NX) (1.2 mb)
Instrumentos ópticos - R-323EX(NX) (1.2 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias