Log:
Assessments - 4, GPA: 4.8 ( )

Instruções de Operação Danby, Modelo DDR2509EE

Fabricante : Danby
Arquivo Tamanho: 258.45 kb
Arquivo Nome : 6bef8410-028d-420c-adbb-fb91d1e36570.pdf
Língua de Ensino: enfr
Ir para baixar



Facilidade de uso


The nameplate contains electrical and other technical data specific to this unit. 5) To avoid the possibility of personal injury, always disconnect the power supply before attempting to clean and/or service the unit. UNIT SPECIFICATIONS Model Number: DDR2509EE DDR3009EE DDR4009EE Dehumidifying Capacity (Pints / Liters) 25 / 11.8 30 / 14.2 40 / 18.9 Electrical Requirements 115 Volts / 60 Hz 115 volts / 60 Hz 115 volts / 60 Hz Power Input (Watts) 380 420 525 Rated Amperage (Dehumidifying) 3.8 4.2 4.8 Air Flow Circulation- High Fan Speed (Cubic Feet per Minute) 180 180 180 Type of Refrigerant R22 R22 R22 Water Tank Capacity (Pints / Liters) 5 / 10.55 5 / 10.55 5 / 10.55 Operating Noise Level (dB A) 52 52 54 Unit Dimensions (Width x Height x Depth) Net Weight (kg / lbs) 13 6/16 x 19 15/16 x 10 15 / 33.1 13 6/16 x 19 15/16 x 10 15 / 33.1 13 6/16 x 19 15/16 x10 15 / 33.1 NOTE: Specifications are subject to change without notice, for further improvements. 4 INSTALLATION LOCATION Select a suitable location, making sure you have easy access to an electrical outlet (avoid the use of extension cords). If it is absolutely necessary to use an extension cord, use an approved “air conditioner” heavy duty extension cord ONLY (available at most local hardware stores). Make sure there are no obstructions restricting airflow through the front air intake grill. Maintain a minimum clearance of at least 20 cm (8”) between adjacent walls and the back of the unit, to allow for proper air circulation and maximum efficiency. To obtain maximum operating efficiency from your dehumidifier, the recommended (room ambient) operating temperatures should be between 6°C (42.8°F)- 35°C (95°F). It is important to remember the efficiency of a dehumidifier will be effected/influenced by the rate at which new humid air (moisture) is allowed to infiltrate the same space/area. To maintain efficiency, the dehumidifier must be operated in an enclosed area. Keep all doors and windows closed. FEATURES • Soft touch (Electronic) Control Key Pads • Auto-Sensing Humidity Control • Adjustable Humidity Settings (35% - 80%) • 2 Fan Speed Settings (High / Low) • Delay Start Protection (Compressor) • Auto-Defrost (De-Icer) • Full Bucket Indicator Light • Easy Roll Castors (4) • Front Mounted Water Tank (Removable) • Direct Drain Option (Hose not Included) • Quiet Operation • Removable Air Filter UNIT PARTS IDENTIFICATION Handle Control Panel Front Panel Air Inlet Air Filter (Side Panel) Water Tank Water level Indicator Easy-roll Castors 5 KEY PAD FUNCTIONS 8 2 3 1) LED Readout (ROOM HUMIDITY): The LED window displays the following information independently: A) Internal (Room/Environment) Relative Humidity Conditions B) Set Operating Relative Humidity Value. NOTE: The LED readout is programmed to default to display the ambient relative humidity conditions. To view the Set Operating Relative Humidity Value, press the “up” or “down” button (once) and the set RH operating value will flash for approximately 5 seconds in the LED window, then revert back to display the internal RH value. 2) ON/OFF Button: Each time this button is pressed the unit turns ON (adjacent indicator light illuminates) or Off (adjacent indicator light is not illuminated) 3) CONTINUOUS: Used for Continuous Dehumidifier Operation (unit will run non-stop). NOTE: Humidity values (settings) cannot be programmed in this mode. The adjacent (green) indicator light illuminates to signify the “continous” mode is currently in operation. 1 4 5 7 6 4) HUMIDITY UP: This button allows you to increase the relative humidity setting. Each time this button is pressed, the RH value setting is increased incrementally by 5% (ranging from 35% - 80%) 5) HUMIDITY DOWN: This button allows you to decrease the relative humidity setting. Each time this button is pressed the RH value setting is decreased incrementally by 5% (ranging from 80% - 35%). 6) HIGH FAN: The adjacent (green) indicator light illuminates when HIGH FAN is selected. 7) LOW FAN: The adjacent (green) indicator light illuminates when LOW FAN is selected. 8) WATER FULL INDICATOR: This (red) light illuminates under the following conditions: A) When the internal water tank is not properly installed inside the cabinet. B) When the internal water tank is full. The water tank must be emptied and replaced back in the cabinet before normal operating conditions can resume. 6 OPERATING INSTRUCTIONS INDICATOR LIGHT FUNCTION Power Light (Green): When the unit is first connected to an electrical outlet, the (green) power light starts to flash and continues to flash until the “on/off” button is pressed. When the “on/off” burron is activated, the flashing (power) light turns to a steady state “on” condition. The dehumidifier will automatically default to the factory default setting (see Factory Default Setting below for details). IMPORTANT NOTE: Depending on the humidity conditions of the surrounding environment, the dehumidifier may not start automatically when the “on...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias