Allow at least 12–18 inches of air space on all sides of the unit for good air circulation. Place the dehumidifier in an area where the temperature will not fall below 65°F (18°C). The coils can become covered with frost at temperatures below 65°F, which may reduce performance. Use the dehumidifier in cooking, laundry, bathing and dishwashing areas that have excessive moisture. NOTE: Place the dehumidifier away from the clothes dryer. Use the dehumidifier to prevent moisture damage anywhere books or valuables are stored. Use the dehumidifier in a basement to help prevent moisture damage. The dehumidifier must be operated in an enclosed area to be most effective. Close all doors, windows and other outside openings to the room. YES NO 12–18. min. 12–18. min. NOTE: The dehumidifier has rollers to aid placement, but it should only be rolled on smooth, flat surfaces. Do not attempt to roll the dehumidifier on carpet or over objects. Automatic Defrost When the dehumidifier control senses frost When the coil is defrosted, the compressor will buildup on the evaporator coil, it will automatically automatically restart and dehumidifying will resume. shut off the compressor. The fan will continue to run to draw air across the coil and melt the frost. 5 There are 3 ways to remove collected water: Use the bucket. When the bucket is removed, the unit will shut off. Empty and replace the bucket. Use a hose. Water can be automatically emptied into a floor drain by attaching a water hose (not included) to the bucket hose nozzle. Using a drill, make a hole at the end of the nozzle located on the lower left side of the bucket. Attach a water hose to the bucket nozzle. Fasten by hand only. Use a floor drain. The unit can also be placed over a floor drain. Using a drill, make a hole at the end of the nozzle located on the lower left side of the bucket. NOTE: The nozzle cannot be fixed after puncture. Use an ordinary garden hose cap (not included) to reclose if necessary. NOTE: Avoid using mechanical tools to tighten the water hose to the bucket nozzle. This may damage the threads on the nozzle. Always make sure the water bucket is locked into place on the dehumidifier. Installing the Water Bucket Lift the bucket and hook the slots on each side onto the posts on the back of the dehumidifier. The bucket should lock securely in place. Make sure the bucket is locked securely in place by pressing down on the upper back edge of the bucket. It will be firmly seated when properly installed. Water Level The dehumidifier will turn off automatically when the bucket is full, or when the bucket is removed or not replaced in the proper position. The bucket must be replaced in the proper position for the dehumidifier to work. The light will be on and the dehumidifier will not run if the bucket is not in the proper position. Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Care and Cleaning Using the dehumidifier. Post Post Removing Collected Water Drill Nozzle Hose Attach hose: 6 Drill hole: Drill 7 Safety Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Consumer Support Care and cleaning of the dehumidifier. ge.com Turn the dehumidifier off and remove the plug from the wall outlet before cleaning. Grille and Case To clean the case: Use water and a mild detergent. Do not use bleach or abrasives. If cabinet paint chips, you can touch it up with a good grade enamel paint to prevent rust. To clean the front grille: Use a vacuum attachment or brush. Air Filter The air filter is on the back of the dehumidifier. It should be checked and cleaned at least every 30 days or more often if necessary. NOTE: DO NOT rinse or put the filter in an automatic dishwasher. CAUTION: DO NOT operate the dehumidifier without the filter because dirt and lint will clog it and reduce performance. To remove: Flex the filter at the lower right corner and slide the upper right side to the left. Release all of the tabs and remove the filter. Wash it in warm soapy water. Rinse and let the filter dry before replacing it. To replace: Hold the filter with the middle tab at the top and place the bottom of the filter in the filter hook. Slide the side filter tabs into the side slots and press the other three tabs into their slots. NOTE: Avoid using a dishwasher to clean the filter. Cleaning the Coil After removing the air filter, clean the coil with a soft brush when the soil is soft and wet. NOTE: Do not allow water to enter the electrical/machine compartment through the circular opening behind the coil. Do not spray the coil with a hose. Water Bucket Every few weeks, rinse the inside of the water bucket with a mild detergent to prevent growth of mold, mildew and bacteria. NOTE: Avoid using a dishwasher to clean the water bucket. Consumer Support Troubleshooting TipsOperating InstructionsSafety InstructionsTroubleshooting Tips Care and Cleaning Safety InstructionsOperating Instructions Troubleshooting Tips… Troubl...

Este manual também é adequado para os modelos :
Dehumidifiers - AHH40LJ (508.11 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias