Log:
Assessments - 1, GPA: 5 ( )

Instruções de Operação Crestron electronic, Modelo CLS-EXP-DIMFLV

Fabricante : Crestron electronic
Arquivo Tamanho: 1.13 mb
Arquivo Nome : cls-exp-dimflv.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


It allows any output channel of a compatible dimmer or switch to control a fully loaded circuit of 0-10 VDC fluorescent ballasts1, non-dimmed lighting (incandescent, HID, magnetic low voltage (MLV), electronic low voltage (ELV), neon/cold cathode, and fluorescent ballast) up to 16 amps, and motors rated up to 1/2 HP @ 120 Volts, 1 HP @ 230/277 Volts. The CLS-EXP-DIMFLV is designed for mounting to a vertical surface. Conduit knockouts are provided on the bottom and lower sides. All connections are made via screw terminals behind the front cover. • Works with Crestron iLux (CLS(I)-C6), CLW-Series dimmers2,3, CLX-Series dimmers3, and DIN-1DIMU43 • Emulates the characteristics of the dimmer that is controlling it • Up to five Expansion Modules can be connected to a single iLux dimmer channel • Supports 0-10 VDC fluorescent, non-dimmed lighting (including HID), and motors rated up to 1 HP • Built-in air gap relay at the output 1. Ballasts must comply with the specifications for control by DC voltage in ANSI C82.11:2002 and IEC60929:2006. 2. CLW-Series devices must have a dedicated neutral. 3. The CLS-EXP-DIMFLV can only be controlled by forward-phase dimmer modules. It is not compatible with the CLX(I)-1DELV4. If connected to a DIN-1DIMU4, the DIN-1DIMU4 must be set to operate as a forward-phase dimmer or a non-dimming switch. CLS-EXP-DIMFLV Physical View Specifications CLS-EXP-DIMFLV Specifications SPECIFICATION DETAILS Load Ratings Output Channels Load Ratings: Lamp Motor Minimum Load at 120 Volts at 230 Volts at 277 Volts Load Types Input Voltages Line Power Control Input Electrical Terminals Enclosure Environmental Temperature Humidity Maximum Heat Dissipation Dimensions Height Width Depth Weight 16 Amps @ 120 - 277 Volts (70 mA max current sink for 0-10 VDC ballasts) 1/2 HP @ 120 Volts, 1 HP @ 230/277 Volts 15 Watts 25 Watts 30 Watts Dimmable Loads 0-10 VDC dimmable fluorescent ballasts (i.e. Advance Mark 7 or other ballasts that are compliant with the specifications for control by DC voltage in ANSI C82.11:2002 and IEC60929:2006) Non-Dim Loads Incandescent, HID, magnetic low voltage (MLV), electronic low voltage (ELV), neon/cold cathode, and fluorescent ballasts Motors Up to 1 HP @ 230/277 Volts 120 to 277 Volts AC, 50/60 Hz 120 or 230 Volts AC, 50/60 Hz, phase independent of line power and load, presents 25 Watts load to the controlling device Captive screw type; Accommodates two 22-12 AWG (0.34-4.0 mm2) wires Surface mount module with (2) integral mounting flanges, galvanized steel w/gray matte powder coat front panel, extruded aluminum heat sink, 1/2” and 3/4” conduit knockouts provided on bottom and lower left & right sides 32° to 104°F (0° to 40°C) 10% to 90% RH (non-condensing) 68 BTU/Hr 8.82 in (22.40 cm) 6.39 in (16.23 cm) 3.18 in (8.08 cm) 3.3 lbs (1.5 kg) (Continued on following page) 1 Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 Installation Guide - DOC. 6680A (2020652) 07.08 Specifications subject to change without notice. ¡Lux™ Expansion Module Crestron CLS-EXP-DIMFLV CLS-EXP-DIMFLVSpecifications (Continued) SPECIFICATION DETAILS Compatible Control Devices CLS(I)-C6 Series CLW Series CLX(I)-1 DIM4 CLX-1 DIM8 CLX(I)-2DIM2 CLX(I)-2DIM8 DIN-1DIMU4 iLux Integrated Lighting System Wall Dimmers and Switches Four Channel Dimmer Module, Single Feed Eight Channel Dimmer Module, Single Feed Two Channel Dimmer Module, Two Feeds Eight Channel Dimmer Module Crestron Green Light™ DIN Rail Universal Dimmer Maximum Expansion Modules per Controller Output 5 Industry Compliance This product is Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc. As of the date of manufacture, the CLS-EXP-DIMFLV has been tested and found to comply with specifications for CE marking. C€ NOTE: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ■ Reorient or relocate the receiving a...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias