Log:
Assessments - 3, GPA: 4.3 ( )

Instruções de Operação Harman Company, Modelo Harman Stove The Harman Magnum Stoker

Fabricante : Harman Company
Arquivo Tamanho: 1.73 mb
Arquivo Nome : b60ff950-b50f-4c1f-bddd-4209f11eefc6.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


FOR USE IN THE U.S. AND CANADA. IF THIS HARMAN STOVE IS NOT PROPERLY INSTALLED, A HOUSEFIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW INSTALLATION DIRECTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONSAND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA. CONTACT YOUR LOCAL AUTHORITY (SUCH AS MUNICIPAL BUILDING DEPARTMENT, FIRE DEPARTMENT, FIRE PREVENTION BUREAU, ETC.) TO DETERMINE THE NEED FOR A PERMIT. CETTE GUIDE D'UTILISATION EST DISPONIBLE EN FRANCAIS. CHEZ VOTRE CONCESSIONNAIRE DE HARMAN STOVE COMPANY. SAVE THESE INSTRUCTIONS. The Harman Magnum Stoker Installation & Operating Manual DO NOT BURN WET COAL. R15 Tested by: OMNI-TEST Laboratory 2 DO NOT BURN WET COAL INDEX Introduction 3 Warnings 3 Packing List 5 Assembly 6 Installation 9 Verti-Flow Stoker Control 10 Operation 14 Maintenance 15 Trouble-Shooting 17 Wiring Diagram 19 Feeder Parts 20 Domestic Hot Water Coil 21 Hot Air Option 22 Warranty 23 3 DO NOT BURN WET COAL WARNINGS INTRODUCTION This all new design by Harman features the Verti-Flow Stoker System. This unique system provides a very wide range of heat output. The Verti-Flow Stoker can operate from 5000 to over 85,000 btu's automatically. This unit has a 100 pound coal capacity and can provide 85,000 btu's for 17 hours or stretch out to over 100 hours when less heat is required. A thermostat is used to regulate the heat output of the stove. When no heat is needed, the stoker stops and only runs to maintain the fire. If heat is needed, the thermostat can turn on the stoker at any time. After the thermostat is satisfied, the stoker will turn off for twelve minutes and then run for four minutes. The four minutes "on" and twelve minutes "off" is a setting that will perform well under most conditions. This "on" and "off" time can be changed to provide more or less heat during the maintenance cycle. This unit must be connected to a chimney capable of providing a .04 minimum draft reading. WARNING!! If the chimney has no draft, coal gases may escape from the unit and stovepipe. These gases are toxic and can be fatal. It is recommended that a gas detector be installed to warn of this condition. Check with your local stove dealer for purchasing a gas detector. 100 LBS. COAL THERMOSTAT Never sleep in the same room with any coal burning stove. TESTING INFORMATION This unit has been tested and approved by OMNI-TEST Laboratories in accordance to the listed codes. 4 DO NOT BURN WET COAL READ THIS Always empty hopper when not burning for more than a week. When left standing for long periods with wet coal, the pusher block will rust and corrode, causing it to seize. If the stoker is then turned "on", damage to the pusher assembly and feed motor will result. This will be considered neglect and will void the warranty on those parts. Always check to see if moving parts are free before using if the unit has not been burned for a period of time. This can best be determined by shaking the adjuster rod. Freshly delivered coal is watered down to eliminate dust when loading and unloading. Wet rice coal does not flow as well as damp or dry coal. We do not recommend burning wet coal, however, we realize if it's the only coal you have it is better to burn it than freeze. If you must burn wet coal, the feed rate must be increased in order to get the same size fire. As the wet coal in the hopper dries out, the feed rate must be decreased. If you don’t, the feeder will over-fire the stove and waste coal. Doing this once or twice a year will not damage your stove as long as it is hot and burning. The damage is caused when the hopper has wet coal in it when th e s to ve is co ld . This will cause rust and corrosion and it is totally the operator’s fault. Usually after the coal dries for three or four days, depending on conditions, it will flow very well and feed properly. Feed rate will be the same as dry coal. Damp coal also should not be left in the hopper of a cold stove. Wet Coal Damp Coal 5 DO NOT BURN WET COAL Parts inside stove Parts inside hopper box grate holder firebricks combustion blower distribution blower ash pan hopper lid hopper hopper support Inside bag (2) terminals for thermostat wire (4) 8-32 x 1/2 screws and nuts control box thermostat motor cover main feeder body adjuster adjuster tube adjuster rod wing nut (2) grate inserts scraper assembly Pusher block Parts inside feeder box PACKING LIST Restricter Plate 6 DO NOT BURN WET COAL ASSEMBLY adjuster tube wing nut adjuster fig 2 feed indicator dust tray fig 1 First, a note to you, the customer. This section on Assembly is in the manual for your information should you ever need to move your unit and to help you understand how each part is installed. It is not intended by Harman Stove Company that you assemble this unit. This job is to be performed by your Harman Dealer who has been taught how to assemble and explain the operation of your new stoker to you. Your dealer will also take a draft reading with the stoker burning. This reading must be ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias