Log:
Assessments - 2, GPA: 3 ( )

Instruções de Operação Harman Company, Modelo 3-90-70738

Fabricante : Harman Company
Arquivo Tamanho: 3.39 mb
Arquivo Nome : 1aa3da63-e4ae-4610-932d-a1721c130415.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


D). Remove the drain valve, at the bottom of the storage tank. Install a .” nipple and tee, and reinstall the drain valve to the tee (4). Run .” copper tubing, with the necessary fittings, between the drain/tee combination and the lower leg of the coil. After all of the connections are completed, you can refill the tank. Restore power to the water heater ONLY after the tank has been completely refilled. EXAMPLE 2: Circulator Method. (more than 10 feet.) Example 2: Circulating pump method. Used when the distance is more than ten feet or when the stove is on a higher level than the existing water heater. In addition to a circulator, you may want to add a aquastat to control the pump according to water temperature. This is not necessary if the circulator is left run continuously. Another option is a gate valve placed near the circulator to control the rate of flow. A). Turn off the water heater and the water supply to it. Drain the tank completely. B). Remove the Temp/Pressure relief valve and discard. Install a short .” nipple and tee (1) along with a new Temp/Pressure relief valve. C). Remove the drain valve, at the bottom of the storage tank. Install a .” nipple and tee, and reinstall the drain valve to the tee (4). D). Install a circulating pump (6) as shown. Run .” copper tubing from the circulator to the lower leg of the coil. This is where the optional gate valve (5) can be installed. E). Install a .” tee and a 150 lb. pressure relief valve (7) in the top leg within 2 feet of the top outlet of the water coil. F). Complete the copper line by running it back to the tee at the top of the water tank, making sure to install a vent elbow and automatic air vent (2) at the high point of the line. The optional aquastat can be installed in this line a maximum of six feet from the stove. The aquastat must be a “close on temperature rise” type and must be wired and set to turn on the circulator when the water temperature reaches 120. Farenheit. The system is now ready to be refilled and power restored to the water heater ONLY after the tank is filled. warranty HARMAN GOLD WARRANTY 6 YEAR TRANSFERABLE LIMITED WARRANTY (Residential) 1 YEAR LIMITED WARRANTY (Commercial) Harman Stove Company warrants its products to be free from defects in material or workmanship, in normal use and service, for a period of 6 years from the date of sales invoice and for mechanical and electrical failures, in normal use and service, for a period of 3 years from the date of sales invoice. If defective in material or workmanship, during the warranty period, Harman Stove Company will, at its option, repair or replace the product as described below. The warranty above constitutes the entire warranty with respect to Harman Stove Company products. HARMAN STOVE COMPANY MAKES NO OTHER WARRANTY, EXPRESSED OR IMPLIED, INCLUDING “ANY” WARRANTY OF MERCHANTABILITY, OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. No employee, agent, dealer, or other person is authorized to give any warranty on behalf of Harman Stove Company. This warranty does not apply if the product has been altered in any way after leaving the factory. Harman Stove Company and its agents assume no liability for “resultant damages of any kind” arising from the use of its products. In addition, the manufacturer and its warranty administrator shall be held free and harmless from liability from damage to property related to the operation, proper or improper, of the equipment. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. THESE WARRANTIES APPLY only if the device is installed and operated as recommended in the user’s manual. THESE WARRANTIES WILL NOT APPLY if abuse, accident, improper installation, negligence, or use beyond rated capacity causes damage. HOW TO MAKE A CLAIM - Any claim under this warranty should be made to the dealer from whom this appliance was purchased. Then contact is made with manufacturer, giving the model and serial numbers, the date of purchase, your dealer’s name and address, plus a simple explanation of the nature of the defect. Extra costs such as mileage and overtime are not covered. Nuisance calls are not covered by these warranties. THIS WARRANTY IS LIMITED TO DEFECTIVE PARTS - REPAIR AND/OR REPLACEMENT AT HARMAN STOVE COMPANY’S OPTION AND EXCLUDES ANY INCIDENTAL AND CONSEQUENTIAL DAMAGES CONNECTED THEREWITH. WARRANTY EXCLUSIONS: Failure due, but not limited to, fire, lightning, acts of God, power failures and/or surges, rust, corrosion and venting problems are not covered. Damage and/or repairs including but not limited to; remote controls, filters, fuses, knobs, glass, ceramic brick panels, ceramic fiber afterburners, door packing, tile, ceramic log sets, paint, batteries or battery back-up and related duct work are not covered. Also excluded from this warranty are consumable or normal wear items including but not limited to; flame guides, grates, coal bars, afterburner hoods, fire brick, gaskets. Additional exclusions f...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias