Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação Hotpoint-Ariston, Modelo C 34S N1 R/HA

Fabricante : Hotpoint-Ariston
Arquivo Tamanho: 764.49 kb
Arquivo Nome : Hotpoint-Ariston-C_34S_N1_R-HA-Pdf-Rus.Pdf
Língua de Ensino: ruiten
Ir para baixar



Facilidade de uso


It contains important information concerning the safe installation and operation of the appliance. ! Please keep these operating instructions for future reference. Make sure that the instructions are kept with the appliance if it is sold, given away or moved. ! The appliance must be installed by a qualified professional according to the instructions provided. ! Any necessary adjustment or maintenance must be performed after the cooker has been disconnected from the electricity supply. Room ventilation The appliance may only be installed in permanently-ventilated rooms, according to current national legislation. The room in which the appliance is installed must be ventilated adequately so as to provide as much air as is needed by the normal gas combustion process (the flow of air must not be lower than 2 m3/h per kW of installed power). The air inlets, protected by grilles, should have a duct with an inner cross section of at least 100 cm2 and should be positioned so that they are not liable to even partial obstruction (see figure A). These inlets should be enlarged by 100% - with a minimum of 200 cm2 - whenever the surface of the hob is not equipped with a flame failure safety device. When the flow of air is provided in an indirect manner from adjacent rooms (see figure B), provided that these are not communal parts of a building, areas with increased fire hazards or bedrooms, the inlets should be fitted with a ventilation duct leading outside as described above. Room requirinc Accent room ventilation “ AB ui FI U Ventilation opening for comburent air Increase in the gap between the door and the flooring ! After prolonged use of the appliance, it is advisable to open a window or increase the speed of any fans used. Disposing of combustion fumes The disposal of combustion fumes should be guaranteed using a hood connected to a safe and efficient natural suction chimney, or using an electric fan that begins to operate automatically every time the appliance is switched on (see figure). □ :<=■ Fumes channelled straight outside Fumes channelled through a chimney or a branched flue system (reserved for cooking appliances) ! The liquefied petroleum gases are heavier than air and collect by the floor, therefore all rooms containing LPG cylinders must have openings leading outside so that any leaked gas can escape easily. LPG cylinders, therefore, whether partially or completely full, must not be installed or stored in rooms or storage areas that are below ground level (cellars, etc.). Only the cylinder being used should be stored in the room; this should also be kept well away from sources of heat (ovens, chimneys, stoves) that may cause the temperature of the cylinder to rise above 50°C. Positioning and levelling ! It is possible to install the appliance alongside cupboards whose height does not exceed that of the hob surface. ! Make sure that the wall in contact with the back of the appliance is made from a non-flammable, heat-resistant material (T 90°C). To install the appliance correctly: • Place it in the kitchen, the dining room or the bedsit (not in the bathroom). • If the top of the hob is higher than the cupboards, the appliance must be installed at least 200 mm away from them. • If the cooker is installed underneath a wall cabinet, there must be a minimum distance of 420 mm between this cabinet and the top of the hob. This distance should be increased to 700 mm if the wall cabinets are flammable (see figure). 14 H Hotpoint ARISTON Min. 600 mm. oooooo o Levelling • Do not position blinds behind the cooker or less than 200 mm away from its sides. • Any hoods must be installed according to the instructions listed in the relevant operating manual. If it is necessary to level the appliance, screw the adjustable feet into the places provided on each corner of the base of the cooker (see figure). The legs* fit into the slots on the underside of the base of the cooker. ! Once the appliance has been installed, the power supply cable and the electrical socket must be easily accessible. ! The cable must not be bent or compressed. ! The cable must be checked regularly and replaced by authorised technicians only. ! The manufacturer declines any liability should these safety measures not be observed. Gas connection Connection to the gas network or to the gas cylinder may be carried out using a flexible rubber or steel hose, in accordance with current national legislation and after making sure that the appliance is suited to the type of gas with which it will be supplied (see the rating sticker on the cover: if this is not the case see beloW). When using liquid gas from a cylinder, install a pressure regulator which complies with current national regulations. To make connection easier, the gas supply may be turned sideways*: reverse the position of the hose holder with that of the cap and replace the gasket that is supplied with the appliance. GB HOOD Electrical connecti...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias