Log:
Assessments - 4, GPA: 3.8 ( )

Instruções de Operação England's Works, Modelo EVOLUTION PELLET STOVE 55-SHPEP

Fabricante : England's Works
Arquivo Tamanho: 951.98 kb
Arquivo Nome : 25-EP.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


This unit must be installed in accordance with the following detailed descriptions of venting techniques; not installing the stove in accordance with the details listed here can result in poor stove performance, property damage, bodily injury or death. England’s Stove Works is not responsible for any damage incurred due to a poor or unsafe installation. If questions arise pertaining to the safe installation of the stove, our Technical Support line (800-245-6489) is available. Contact your local code official to be certain your installation meets local and national fire codes and if you’re uncertain about how to safely install the stove, we recommend contacting a local NFI certified installer to perform the installation. Venting Guidelines • ALWAYS install vent pipe in strict adherence with the instructions and clearances included with your venting system. • DO NOT connect this pellet stove to a chimney flue which also serves another appliance. • DO NOT install a flue pipe damper or any other restrictive device in the exhaust venting system of this unit. • USE an approved wall thimble when passing through a wall and a ceiling support/fire stop when passing through a ceiling. • ONLY use 3.0” or 4.0” Type L or Type PL pipe approved for pellet stove venting; DO NOT use galvanized or B-Vent pipe. • SEAL each joint of pellet vent with high temperature silicone (Part # ACRTV3) to prevent smoke spillage into the home. • AVOID excessive horizontal runs and elbows, as both will reduce the draft of the venting system and will result in poor stove performance. • INCLUDE as much vertical pipe as possible to prevent smoke from the unit from entering your home in the event of a power outage. • INSPECT your venting system often, to be certain it is clear of fly-ash and other restrictions. • CLEAN the venting system as detailed in the maintenance section of this manual. WARNING: Venting system surfaces get HOT, and can cause burns if touched. Noncombustible shielding or guards may be required. Page | 8 INSTALLATION INSTALLATION Additional Venting Information • Do not mix and match components from different pipe manufacturers when assembling your venting system (i.e. Do NOT use venting pipe from one manufacturer and a thimble from another). • We require a minimum vertical rise of 36 in. (3 ft.) of pipe to create natural draft in the system, which helps evacuate smoke from the stove in the event of a power failure or combustion blower failure. • Venting systems 15.0 ft. or shorter may be composed entirely of 3.0 in. pellet pipe; to reduce frictional losses, venting systems longer than 15.0 ft. should be composed of 4.0 in. pellet pipe. • Do not terminate the venting system directly beneath any combustible structure such as a porch or deck. • Follow NFPA 211 rules listed below for venting system termination location relative to windows and other openings in the dwelling. o NFPA 211 (2003 ed.) Section 10.4 Termination: 10.4.5 (1) The exit terminal of a mechanical draft system other than direct vent appliances (sealed combustion system appliances) shall be located in accordance with the following: • (a) Not less than 3 ft. (.91 m) above any forced air inlet located within 10 ft. (3.0m). • (b) Not less than 4 ft. (1.2 m) below, 4 ft. (1.2 m) horizontally from or 1 ft. (305 mm) above any door, window or gravity air inlet into any building. • (c) Not less than 2 ft. (0.61 m) from an adjacent building and not less than 7 ft. (2.1 m) above grade when located adjacent to public walkways. • Distance between the termination opening and grade should be a minimum of 24 in. contingent on the grade surface below the termination. When determining the termination height above grade, consider snow drift lines and combustibles such as grass or leaf accumulation. In areas where significant snowfall is possible, the termination height must be sufficiently high to keep the termination free of snow accumulation. Page | 9 INSTALLATION INSTALLATION Approved Venting Method 1: Through the Wall • Generally the simplest installation method, venting through the wall using our AC-3000 kit (or similar venting system) is also the preferred venting method. It minimizes horizontal pipe, allows the stove to be installed close to the wall and keeps the clean-out tee on the outside of the house, for ease of cleaning. • When installing any venting system, Type L or Type PL pipe must be used and all clearances to combustibles (listed by the pipe manufacturer) must be strictly adhered to. • Use the pipe manufacturer’s approved thimble for passing through a combustible wall, and maintain at least the minimum clearances to combustibles. • Use an appliance collar where the pellet vent connects to the exhaust output of the pellet stove and attach the appliance collar to the exhaust blower output using three sheet metal screws. • Secure the pellet vent to the outside of the house using a wall strap just below the 90 degree elbow. • Seal each pipe connection joint with hi...

Este manual também é adequado para os modelos :
Placa - EVOLUTION PELLET STOVE 25-EP (951.98 kb)
Placa - EVOLUTION PELLET STOVE 55-TRPEP (951.98 kb)
Placa - 25-EP (951.98 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias