Log:
Assessments - 4, GPA: 3.8 ( )

Instruções de Operação DeLonghi, Modelo DEGESC24SS

Fabricante : DeLonghi
Arquivo Tamanho: 1.13 mb
Arquivo Nome : DEGESC24SS.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


3.1). 2. Remove the Bracket and Strain Relief Group by unscrewing the Bracket Fixing Screws. 3. Mount the Power Cord Bracket (supplied with the range in a separate kit) inside the Opening For Electrical Connection by screwing the 2 Fixing Screws (as indicated in Figure 3.5). 4. Insert the Power Cord through the hole in the Power Cord Bracket; then tighten the Power Cord by using a suitable Strain Relief. Allow enough slack to easily attach the cord terminals to the Terminal Block. 5. Remove the 3 wire terminal nuts and washers from the Terminal Block. 6. Remove the Ground Strap from the frame of range and terminal by removing its screw and cutting it as shown in Figure 3.7. 7. Plug the terminal holes of Power Cord. The Neutral Wire of the Power Cord must be connected to the neutral terminal located in the center of Terminal Block; the Power Wires must be connected to the outside terminals; the Ground Wire must be attached to the frame of range by using the (Ground) identified Grounding Screw. 8. Plug washers and tighten nuts securely. 9. Assemble the Terminal Block Access Plate. 3-Wire Power Cord Installation (See Figures 3.1, 3.4, 3.5 and 3.6) 1. Remove the Terminal Block Access Plate on the back of the range by unscrewing the 4 fixing Screws (fig. 3.1). 2. Remove the Bracket and Strain Relief Group by unscrewing the Bracket Fixing Screws. 3. Mount the Power Cord Bracket (supplied with the range in a separate kit) inside the Opening For Electrical Connection by screwing the 2 Fixing Screws (as indicated in Figure 3.5). 4. Insert the Power Cord through the hole in the Power Cord Bracket; then tighten the Power Cord by using a suitable Strain Relief. Allow enough slack to easily attach the cord terminals to the Terminal Block. 5. Remove the 3 wire terminal nuts and washers from the Terminal Block. 6. Plug the terminal holes of Power Cord. The Neutral or Ground Wire of the Power Cord must be connected to the neutral terminal located in the center of Terminal Block. The Power Wires must be connected to the outside terminals. 7. Plug washers and tighten nuts securely. Do not remove Ground strap. 8. Assemble the Terminal Block Access Plate. Strain Relief Bracket Bracket.. Fixing Screws Power Cord.. Bracket Hole D 1" 9/64.. (29 mm) Power Cord.. Bracket.. Fixing Screws Opening For.. Electrical.. Connection Neutral Wire Power Wires Power Cord .. Terminal Block Ground strap Neutral Wire Power Wires Power Cord .. Terminal.. Block Grounding Wire Cut Ground Strap Grounding Screw Fig. 3.4 Fig. 3.5 Fig. 3.6 Fig. 3.7 19 3-Wire Conduit Installation (See Figures 3.1, 3.4, 3.8 and 3.9) 1. Remove the Terminal Block Access Plate on the back of the range by unscrewing the 4 fixing Screws (fig. 3.1). 2. Remove the Bracket and Strain Relief group by unscrewing the Bracket Fixing Screws. 3. Mount the Conduit Bracket (supplied with the range in a separate kit) inside the Opening For Electrical Connection by screwing the 2 Fixing Screws (as indicated in Figure 3.8). 4. Feed 1/2” (1.3 cm) trade size Conduit through the hole in the Conduit Bracket and secure to the Conduit Bracket with a Conduit Clamp. 5. Remove the 3 wire terminal nuts and washers from the Terminal Block. 6. Plug the terminal holes of conductors. The Neutral or Ground Wire of the Power Cord must be connected to the neutral terminal located in the center of Terminal Block. The Power Wires must be connected to the outside terminals. 7. Plug washers and tighten nuts securely. Do not remove Ground strap. 8. Assemble the Terminal Block Access Plate. 4-Wire Conduit Installation (See Figures 3.1, 3.4, 3.8 and 3.10) 1. Remove the Terminal Block Access Plate on the back of the range by unscrewing the 4 fixing Screws (fig. 3.1). 2. Remove the Bracket and Strain Relief group by unscrewing the Bracket Fixing Screws. 3. Mount the Conduit Bracket (supplied with the range in a separate kit) inside the Opening For Electrical Connection by screwing the 2 Fixing Screws (as indicated in Figure 3.8). 4. Feed 1/2” (1.3 cm) trade size Conduit through the hole in the Conduit Bracket and secure to the Conduit Bracket with a Conduit Clamp. 5. Remove the 3 wire terminal nuts and washers from the Terminal Block. 6. Remove the Ground Strap from the frame of range and terminal by removing its screw and cutting it as shown in Figure 3.10. 7. Plug the terminal holes of conductors. The Neutral Wire of the Power Cord must be connected to the neutral terminal located in the center of Terminal Block; the Power Wires must be connected to the outside terminals; the Ground Wire must be attached to the frame of range by using the (Ground) identified Grounding Screw. 8. Plug washers and tighten nuts securely. 9. Assemble the Terminal Block Access Plate. Counduit.. Bracket Conduit Bracket.. Fixing Screws Opening For.. Electrical.. Connection Hole D 7/8".. (22.5 mm) Conduit Neutral Wire Power Wires Terminal Block Ground strap Conduit Clamp Conduit Neutral Wire Power Wires Terminal Block Conduit Clamp Groundi...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias