Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação Bosch, Modelo HGV745356Z/01

Fabricante : Bosch
Arquivo Tamanho: 2.51 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :
Placa - HGV745356Z/01 (496.55 kb)

Facilidade de uso


The door handle cannot support the weight of the appliance and could break. Damage to the plinth drawer Caution! Do not place hot objects in the plinth drawer. It could be damaged. Set-up, gas and electricity connection Gas connection Installation must only be performed by an approved expert or a licensed after-sales service engineer in accordance with the instructions specified under "Gas connection and conversion to a different gas type". For the licensed expert or after-sales service Caution! ¦ The setting conditions for this appliance are specified on the rating plate on the back of the appliance. The gas type set in the factory is marked with an asterisk (*). ¦ Before setting up the appliance, check the grid access conditions (gas type and gas pressure) and ensure that the gas setting of the appliance meets these conditions. If the appliance settings have to be changed, follow the instructions in the section "Gas connection and conversion to a different gas type". ¦ This appliance is not connected to a waste gas main. It must be connected and commissioned in accordance with the installation conditions. Do not connect the appliance to a waste gas main. All ventilation regulations must be observed. ¦ The gas connection must be made via a fixed, i.e. not mobile connection (gas line) or via a safety hose. ¦ If using the safety hose, ensure that the hose is not trapped or crushed. The hose must not come into contact with hot surfaces. ¦ The gas line (gas pipe or safety hose) can be connected to the right or left-hand side of the appliance. The connection must have an easily accessible locking device. Safety information The rated working pressure of your appliance is: for natural gas (G20) 2 kPa; for LPG (G30) 3 kPa; for LPG (G31) 3,7 kPa. Your appliance must be operated with these pressures. All the information on the rating plate of your appliance is based on these pressures. The manufacturer takes no responsibility for the resulting operability or performance of the appliance or for other risks if the appliance is operated with pressures other than those specified. Caution! If the pressure of your local gas supply is higher than: natural gas (G20) 2,5 kPa; LPG (G30) 3,6 kPa; or LPG (G31) 4,5 kPa; for safety reasons, the appliance must be equipped with a suitable pressure regulator. The connection, maintenance and setting of the pressure regulator must be carried out by an approved gas fitter. If you do not know the pressure of your local gas supply, ask your gas supplier. For your safety This appliance is adjusted to operate on LPG only. Faults in the gas installation/smell of gas If you notice a smell of gas or faults in the gas installation, you must ¦ immediately shut off the gas supply and/or close the gas cylinder valve ¦ immediately extinguish all naked flames and cigarettes ¦ switch off electrical appliances and lights ¦ open windows and ventilate the room ¦ call the aftersales service or the gas supplier Burn back Fire in burner tube or chamber In the event of a burn-back, where the flame burns back to the jet, immediately turn off the gas supply at the control valve on the panel. After ensuring the flame is extinguished, re-light the appliance in the normal manner. Should the appliance again burn back, close the control valve and call a service technician. Do not use the appliance again until the service technician has declared that it is safe to do so. Gas-pressure regulator This appliance requires an operating pressure of 2,8 kPa at the appliance. A suitable LPG regulator that coplies with the requirements of SANS 1237 must be installed. Important information for the user This appliance may only be installed by a registeres LP Gas installer. All registered installers are issued with a card carrying their registration number. Ask to be shown the card before allowing the installation work to be shown the card before allowing the installation work to commence and make a note of the installer QCC number. Upon completion of the installation, the installer is required to explain the operational details of the appliance together with the safety instructions. You should only sign for acceptance of the installation and be provided with a copletion certificate. You should only sign for acceptance of the installation when the installation is completed to your satisfaction. Note that your invoice is required in the event that you wish make a quarantee claim. Important information for the installer This appliance may only be installed by a registered LP Gas installer registered with the Liquefied Petroleum Gas Association of Southern Africa. The appliance must be installed in accordance with the requirements of SANS 10087-1 and any fire department regulations and/or local bylaws applicable to the area. If in doubt check with the relevant authority before undertaking the installation. Upon completion of the installation you are required to fully explain and demonstrate to the user the operational details and...

Este manual também é adequado para os modelos :
Placa - HGV745356Z/02 (2.51 mb)
Placa - HGV745356Z/03 (2.51 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias