Log:
Assessments - , GPA: ( )

Instruções de Operação Avanti, Modelo ELECRIC RANGE ER2001G

Fabricante : Avanti
Arquivo Tamanho: 1.65 mb
Arquivo Nome : er2001g_-_er2002css_-_er2401g_-_er2402css.pdf

Língua de Ensino: enes

O documento está colocado, por favor, espere
O documento está colocado, por favor, espere

Facilidade de uso


70 (Latest Edition) and local electrical code requirements. Installation should be made by a licensed electrician. • The range may be connected by means of permanent “Hard Wiring” or “Power Supply Cord Kit”. Power supply cord is not supplied, but is available through your local electric supply house. • Use only 3-conductor or 4-conductor UL listed range cord rated at 40 amps with 125/250V minimum voltage range. These cords may be provided with strain relief or conduit connector. • The range must be connected to the proper electrical voltage and frequency as specified on the rating label. • The range can be connected directly to the fused disconnect (or circuit breaker box) through flexible, armoured or non-metallic sheathed, copper cable (with grounding wire). Allow two to three feet of slack in the line so that it can be moved if servicing is ever necessary. • For personal safety, the range must be properly grounded. • Remove house fuse or open circuit breaker before beginning installation. • Do not attempt to repair or replace any part of the appliance unless it is specifically recommended in this manual. All other servicing should be referred to a qualified technician. • To minimize the possibility of electric shock, disconnect this appliance from the A/C power supply before attempting any maintenance. NOTE: Turning the appliance off does not disconnect the appliance from the power supply. We recommend having a qualified technician service your appliance. 3-Wire Power Cord Installation ScrewsTerminal Block Access Plate BracketPower CordPower WiresNeutral WireCut Ground StrapTerminal Block • Remove the Terminal Block Access Plate on the back of range by removing the 2 fixing screws. • Assemble the strain relief in the hole on bracket. • Insert the power cord through the strain relief and tighten. • Allow enough slack to easily attach the cord terminals to the terminal block. • Remove the 3 wire terminal nuts and washers from the terminal block. • Plug the terminal holes of power cord. The neutral or ground wire of the power cord must be connected to the neutral terminal located in the center of terminal block. The power leads must be connected to the outside terminals. • Plug washers and tighten nuts securely. • Assemble the Terminal Block Access Plate. Grounding ScrewGrounding WireBracketPower CordPower WiresNeutral WireTerminal BlockCut Ground Strap 4-Wire Power Cord Installation Grounding ScrewGrounding WireBracketPower CordPower WiresNeutral WireTerminal BlockCut Ground Strap • Remove the Terminal Block Access Plate on the back of range by removing the 2 fixing screws. • Assemble the strain relief in the hole on bracket. • Insert the power cord through the strain relief and tighten. • Allow enough slack to easily attach the cord terminals to the terminal block. • Remove the 3 wire terminal nuts and washers from the terminal block. • Remove the ground strap from the frame of range and terminal by removing its screw and cutting is as shown. • Plug the terminal holes of power cord. The neutral wire of the power cord must be connected to the neutral terminal located in the center of terminal block. The ground wire of the power supply cord must be attached to the frame of range by using the green colored grounding screw. The power leads must be connected to the outside terminals. • Plug washers and tighten nuts securely. • Assemble the Terminal Block Access Plate. . LEVELING THE RANGE The range must be level to obtain proper operating. The four screws type leveling legs located on the corners at the bottom of range should be adjusted by turning them clockwise to make the range higher or counter-clockwise to lower the range until the range is level. Use a level on surface units to check the leveling of the range. . ANTI-TIP BRACKET INSALLATION To reduce the risk of tipping the range by abnormal usage or improper door loading, the range must be secured by properly installing the anti-tip device packed with the appliance. • Place the anti-tip bracket on the floor as shown figure. Anti-tip bracket can be installed on either right or left side. • Make the locations of 2 holes of ant-tip bracket on the floor. • Use a 5/16” masonry drill bit and insert plastic anchor. • Secure bracket to floor using screws supplied. • Slide appliance into position. NOTE: If range is relocated, the bracket must be removed and installed in new location. ATTENTION: OVENS VARY: COOKING TIMES AND OVEN TEMPERATURES MAY NEED ADJUSTMENT AVISO: HORNOS PUEDEN VARIAR: EL TIEMPO DE COCCION PUEDE VARIAR. EN ESE CASO AJUSTES DE LA TEMPERATURA PUDIERAN SER NECESARIOS OPERATING YOUR RANGE . CONTROL PANEL 1. Oven Function Selector Knob 5. Rear Right Burner Control Knob 2. Oven Thermostat Knob 6. Front Right Burner Control Knob 3. Front Left Burner Control Knob 7. Oven Power Indicator Light 4. Rear Left Burner Control Knob 8. Burners Power Indicator Light OVEN FUNCTION SELECTOR KNOB There are three functions – OVEN LIGHT, BAKE AND BROIL. To switch...

Este manual também é adequado para os modelos :
Placa - ELECRIC RANGE ER2402CSS (1.65 mb)
Placa - ER2002CSS (1.65 mb)
Placa - ER2402CSS (1.65 mb)
Placa - ELECRIC RANGE ER2002CSS (1.65 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias