Log:
Assessments - 1, GPA: 5 ( )

Instruções de Operação GE, Modelo ZDP36N4RHSS4

Fabricante : GE
Arquivo Tamanho: 135.39 kb
Arquivo Nome : ad756a19-713c-49c7-a1b8-b2dbc8b2ef18.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


All Professional Ranges are factory set for natural or liquid propane gas. The correct model should be ordered for the installation situation. 36" Natural Gas Model ZDP36N4RHSS–4 gas burners and grill 36" Liquid Propane Gas Model ZDP36L4RHSS–4 gas burners and grill Note: Conversion kits (WB49X10132, Natural to LP and WB49X10133, LP to Natural) are available if the wrong gas type was ordered. High Altitude kit, WB49X10130 (for Natural and LP gas models), is also available. The kits must be installed by a qualified service technician at additional cost. Installation Information Before installing, consult installation instructions packed with product or online at Monogram.com for current dimensional data. A 36" or 42" wide professional vent hood with a minimum 600 CFM is recommended for installation over this range. Advance Planning Refer to dimensional drawings for appropriate placement and necessary clearances when planning the installation. • Cabinetry cannot be installed directly above the range. • Working areas adjacent to the range should have 18" minimum clearance between countertop and cabinet bottom. • Clearance between range and side wall or combustible material must be at least 12" on each side. If the range is installed in an island • Allow 12" minimum clearance at the back to combustible materials. • The vent hood blower should provide at least 600 CFM and up to 1200 CFM. • Installation must conform with local codes. In the absence of local codes, the range must comply with the National Fuel Gas Code, ANSI Z223.1-1990. Listed by Underwriters LaboratoriesR22" 1-1/2" 35-1/4" to 36-3/4" 28-1/4" 35-7/8" OptionalBacksplash 12" Clearances between range and side wall or combustible material must For answers to your Monogram,® GE Profile™ or be at least 12" on each side. GE® appliance questions, visit our website at GEAppliances.com or call GE Answer Center® Specification Revised 10/05 service, 800.626.2000. ZDP36N4RHSS (Natural Gas) ZDP36L4RHSS (Liquid Propane) – GE Monogram 36" Dual Fuel Professional Range with 4 Burners and Grill Electrical Requirements Ranges must be supplied with 208/240V, 60Hz, and connected to an individual, properly grounded branch circuit protected by a circuit breaker or time-delay fuse. Install a 30-amp circuit for 36" ranges. The receptacle must be a NEMA 14-50R device to accept the four-prong plug on the range. Locate gas and electric as shown 4" 1-1/2" 4" 4" 4" 12" 12" Gas Supply Electric 36" Supply Gas Supply • Natural gas models are designed to operate at 5" water column pressure. A regulator is required at the natural gas source to provide maximum of 7" water pressure to the range regulator. • The liquid propane models are designed to operate at 10" water column pressure. A regulator is required at the LP source to provide maximum of 14" water pressure to the range regulator. Optional Backsplash Accessories The range requires a 12" minimum clearance to a vertical combustible surface at the rear. A backsplash is required for installat...

Este manual também é adequado para os modelos :
Placa - ZDP36L4RHSS4 (135.39 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias