Log:
Assessments - 2, GPA: 4 ( )

Instruções de Operação Bosch, Modelo BOSCH OVEN

Fabricante : Bosch
Arquivo Tamanho: 2.53 mb
Arquivo Nome : 9000135012_10086B_3lang.pdf
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


Note: DO NOT use caulk or glue/adhesive of any kind. Install Backwall Trim Note: This step is only required if the countertop does not connect behind the range (i.e.; when replacing a free-standing range). See “Cabinet Requirements” on page 6 for more information English 7 English 8 Install 2 screws through holes in trim and in range backwall. See Figure 6: Backwall Trim Strip and Figure 7: Install Backwall Trim Strip Connect Electric - Range Cord Note: In Canada, the range is shipped from the factory with the range cord already installed. Continue to “Complete the installation” on page 15. For installations other than those in Canada, connect the range cord at the terminal block (See next page for detailed instructions). Access the terminal block by removing the cover in the lower right hand corner of the range back panel. Install Strain Relief Warning: The strain relief provided with your range cord must be properly installed. Place strain relief in knockout below terminal block. See Figure 8: Strain Relief Knockout. Feed range cord through hole and strain relief up to terminal block. Allow for slack in the cord between the strain relief and terminal block. Once cord Figure 6: Backwall Trim Strip Figure 7: Install Backwall Trim Strip Backwall Trim Strip Back of Range length/ slack has been adjusted, attach strain relief per instructions included with strain relief. Tip: The knockout panel below the terminal block can be removed from the range to install the strain relief: Remove knockout panel from range, install strain relief in panel and reattach. DO NOT remove entire range back panel. Figure 8: Strain Relief Knockout Warning: Risk of Electric Shock or Fire. Frame grounded to neutral through a ground strap. Grounding through the neutral conductor is prohibited for new branch-circuit installations (1996 NEC), mobile homes, and recreational vehicles, or in an area where local codes prohibit grounding through the neutral conductor. For installations where grounding through the neutral conductor is prohibited, (a) disconnect the link from the neutral, (b) use grounding terminal or lead to ground unit, (c) connect neutral terminal to lead branch circuit neutral in usual manner (when the appliance is to be connected by means of a cord kit, use 4conductor cord for this purpose). Use only cord kits rated 125/250 volts (minimum), 40 or 50 amperes (depending on local code) and labeled “For Use with Ranges”. Strain relief provided with cord must be installed per instructions Figure 9: Grounding Requirements Warning: To prevent electrical shock, the grounding prong on the range cord should not be cut or removed under any circumstances. It must be plugged into a matching grounding type receptacle and connected to a correctly polarized 240- Volt circuit. If there is any doubt as to whether the wall receptacle is properly grounded, have it checked by a qualified electrician. English 9 Four Wire Range Cord Connection 1. Disconnect electrical power at breaker box. (Recommended Method) 2. Remove the terminal block cover to expose the terminal block Figure 10: 4 Wire Connection 3. Remove top nut, star washer, and round washer from each post. Note: DO NOT remove last round washer, last nut or internal wiring leads. 4. Remove screw from bottom end of ground strap. 5. Remove ground strap from center post, rotate so that wide end is at top and attach wide end to range through hole below junction box. Attach green wire on top of ground strap. Tighten Screw. ground strap green ground screw ground wire Figure 11: Four Wire Range cord Connection - Ground Strap and Wire 6. Attach red wire, round washer, star washer and nut IN THIS ORDER to left post. 7. Attach white wire, round washer, star washer and nut IN THIS ORDER to center post. English 10 8. Attach black wire, round washer, star washer and nut IN THIS ORDER to right post. white black red Figure 12: Four Wire Range Cord Connection (continued) 9. Tighten all connections securely and replace terminal block cover. 10. Properly secure strain relief (see previous section). Note: DO NOT plug in range at this time. Three Wire Range Cord Connection The Four Wire Connection (above) is preferred, but where local codes and ordinances permit grounding through neutral and where conversion to four wire is impractical, the unit may be connected to the power supply via a three wire connection. 1. Disconnect electrical power at breaker box. 2. Remove the terminal block cover to expose the terminal block. Figure 13: Terminal Block 3. Remove top nut, star washer, and round washer from each post. Note: DO NOT remove last round washer, last nut or internal wiring leads. 4. Attach white wire, round washer, star washer and nut IN THIS ORDER on top of ground strap on center post. 5. Attach red wire, round washer, star washer and nut IN THIS ORDER to left post. English 11 6. Attach black wire, round washer, star washer and nut IN THIS ORDER to right post. red white black ground strap Figure 14: Thre...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias