|
Facilidade de uso
2 Clock Overview..................................................... 2 Front View........................................................... 2 Back View............................................................ 2 LCD Display......................................................... 3 Remote Sensor (THGN122N)............................. 4 Getting Started...................................................... 4 Batteries.............................................................. 4 Remote Sensor...................................................... 4 Sensor Data Transmission.................................. 5 Clock ..................................................................... 6 Clock Reception.................................................. 6 Reception Signal ................................................ 6 Set Clock............................................................. 6 Alarm...................................................................... 6 Barometer.............................................................. 7 Set Altitude.......................................................... 7 Weather Forecast................................................. 7 Temperature and Humidity.................................. 7 Temperature, Humidity And Pressure Trend...... 8 Ice Warning ....................................................... 8 Hi / Lo Temperature / Humidity Alarms................ 8 Heat Index............................................................ 8 Comfort Zone....................................................... 9 Moon Phase.......................................................... 9 Reset..................................................................... 9 Precautions .......................................................... 9 Specifications....................................................... 10 About Oregon Scientific...................................... 11 EU-Declaration of Conformity............................. 11 1 ENINTRODUCTION INTRODUCTION Thank you for selecting this Oregon ScientificTM Wireless Weather Station with Temperature / Humidity, Ice Alert and Radio-Controlled Clock (BAR388HG). This clock is supplied with a remote sensor (THGN122N) and can support up to 3 sensors in total (additional sensors sold separately). NOTE Please keep this manual handy as you use your new product. It contains practical step-by-step instructions, as well as technical specifications and warnings you should know about. CLOCK OVERVIEW FRONT VIEW 1. SNOOZE 2. Weather Forecast Area 3. Outdoor Temperature Area 4. Indoor Temperature Area 5. Clock / Alarm Area 6. : View alarm status; set alarm BACK VIEW 1. / : Increase / decrease setting; activate / deactivate clock reception signal 2. MODE: Change settings / display 3. CHANNEL: Switch remote sensor display 4. MEM: View current, maximum and minimum temperature / humidity 5. EU / UK switch 2 EN 6. PRESSURE: Select pressure unit; set altitude Outdoor Temperature Area: 7. HEAT INDEX: Display heat index . 8. TEMP / HUMIDITY HI / LO : Change settings . or enable / disable hi or lo temperature / humidity alarm for channel 1 . 9. °C / °F: Select temperature unit 10. RESET: Reset unit to default settings . 11. Battery compartment LCD DISPLAY 1. Heat index icon 2. Hi / lo temperature alarm Weather Forecast Area: 3. Sensor reception icon 4. Sensor battery low 5. Max / min icon 6. Temperature display . 7. Ice warning is active 8. Hi / lo humidity alarm 9. Temperature trend 10. Humidity trend 11. Humidity display Indoor Temperature Area: 1. Pressure trend . 2. Weather forecast 3. Comfort zone . 4. Pressure icon 5. Altitude icon 1. Indoor sensor icon 6. Pressure / altitude unit 2. Max / min icon 7. Heat index 3. Temperature display 4. Temperature trend 5. Humidity trend 6. Humidity display .............. 3 EN Clock / Alarm Area: 1. Alarm set 2. AM / PM icon 3. Clock signal reception 4. Low battery icon 5. Clock 6. Alarm mode icon 7. Moon phase .. 1. LED status indicator: Blinks red during data transmission 1. Wall mount hole 2. RESET hole 3. CHANNEL switch 4. Battery compartment GETTING STARTED BATTERIES Insert batteries before first use, matching the polarity (+ and -). Press RESET after each battery change. indicates main unit batteries are low. NOTE Do not use rechargeable batteries. We recommend that you use alkaline batteries with this product for longer usage and lithium batteries in temperatures below freezing. REMOTE SENSOR The sensor collects temperature and humidity readings approx. every 40 seconds and sends them to the main unit. The main unit can collect data from up to 3 sensors. To set up the sensor: 1. Remove the screws from the battery door. 2. Insert the batteries, matching the polarity (+ / -). REMOTE SENSOR (THGN122N) 4 EN 3. Select a channel. Make sure you use a different channel for each sensor. 4. Place the sensor near the main unit. Press RESET on the sensor. 5. Simultaneously press CHANNEL and MEM on the main unit ...
Este manual também é adequado para os modelos :Estação Meteorológica - BAR388HG (3.78 mb)