Log:
Assessments - 3, GPA: 3 ( )

Instruções de Operação Oregon Scientific, Modelo BAR206A

Fabricante : Oregon Scientific
Arquivo Tamanho: 579.05 kb
Arquivo Nome : BAR206A.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


°C / °F: Select temperature unit ICON DESCRIPTION Main unit is searching for sensor(s). A channel has been found. The sensor cannot be found. TIP The transmission range may vary depending on many factors. You may need to experiment with various locations to get the best results. CLOCK CLOCK RECEPTION FRONT VIEW (FIG 1) 1. LED status indicator 2. Wall mount hole 3. Battery compartment 4. RESET hole 5. CHANNEL switch GETTING STARTED INSERT BATTERIES 1. Remove the battery compartment. 2. Insert the batteries, matching the polarities (see FIG 2). 3. Press RESET after each battery change. LOCATION MEANING Clock / alarm and indoor Main unit batteries low temperature area Outdoor temperature area Sensor batteries low This product is designed to synchronize its clock automatically with WWVB-60 signal, within 3200km (2000 miles) of Fort Collins Colorado. To enable / disable signal reception: Press and hold to enable or to disable signal reception. Reception takes 2-10 minutes. If the signal is weak, it can take up to 24 hours to get a valid signal. If signal reception is unsuccessful, place your unit next to a window, press and hold to force another signal search. Clock signal reception indicator: STRONG SIGNAL WEAK SIGNAL NO SIGNAL REMOTE SENSOR 1. Remote sensor reception indicator 2. Indoor temperature 3. Indoor humidity Wireless sensor included does not include humidity. To receive outdoor humidity you need a wireless sensor with the humidity function. 4. Clock signal reception indicator 5. MODE: Change settings / display 6. LIGHT: Activate backlight for 5 seconds 7. / : Increase / decrease setting; activate / deactivate clock reception signal 8. Outdoor temperature 9. Weather forecast 10. Time zone 11. Clock with weekday 12. MEM: View current, maximum and minimum temperature / humidity 13. Ice alert LED indicator BACK VIEW (FIG 2) The main unit can collect data from up to 3 sensors. To set up the sensor: 1. Open the battery compartment (see FIG 3). 2. Select a channel then press RESET. 3. Close the battery door. 4. Place the sensor within 30 m (98 ft) of the main unit using the table stand or wall mount. TIP Ideal placements for the sensor would be in any location on the exterior of the home at a height of not more than 5 ft and which can shield it from direct sunlight or wet conditions for an accurate reading. Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing. SENSOR DATA TRANSMISSION To search for a sensor: Press and hold + MODE. The sensor reception icon in the remote sensor area shows the status: MANUALLY SET CLOCK To set the clock manually, disable the signal reception first. 1. Press and hold MODE. 2. Press or to change the settings. 3. Press MODE to confirm. 4. The settings order is: time zone, 12/24 hr format, hour, minute, year, calendar mode (day – month / month – day), month, day and language. Select the time zone: (P) Pacific, (E) Eastern, (C) Central or (M) Mountain. The language options are English (E), German (D), French (F), Italian (I), and Spanish (S). To select display mode: Press MODE to choose between clock with seconds / weekday / calendar. WEATHER FORECAST This product forecasts the next 12 to 24 hours of weather within a 30-50 km (19-31 mile) radius (US- with a 75% accuracy). Sunny Partially Cloudy Cloudy Rainy Snowy TEMPERATURE AND HUMIDITY To toggle temperature unit: Press °C / °F. To auto-scan between sensors: Press and hold + MEM to display each sensor’s data for 3 seconds. To end press . bar206A_M_EN_R0.indd 1 2007.6.7 11:25:43 AM To toggle between current, minimum and maximum records for the selected sensor: Press MEM repeatedly. To clear the records: Press and hold MEM. ICE WARNING If the channel 1 sensor falls between 3°C to -2 °C (37°F to 28°F), LED indicator will flash, and will stop flashing once the temperature is out of this range. BACKLIGHT Press LIGHT to activate backlight for 5 seconds. RESET Press RESET to return to the default settings. PRECAUTIONS • Do not subject the unit to excessive force, shock, dust, temperature or humidity. • Do not cover the ventilation holes with any items such as newspapers, curtains etc. • Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth. • Do not clean the unit with abrasive or corrosive materials. • Do not tamper with the unit’s internal components. This invalidates the warranty. • Only use fresh batteries. Do not mix new and old batteries. • Images shown in this manual may differ from the actual display. • When disposing of this product, ensure it is collected separately for special treatment. • Placement of this product on certain types of wood may result in damage to its finish for which Oregon Scientific will not be responsible. Consult the furniture manufacturer's care instructions for information. • The contents of this manual may not be reproduced without the permission of the manufacturer. • Do not dispose old batte...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias