Log:
Assessments - 5, GPA: 4 ( )

Instruções de Operação Watlow Electric, Modelo 734

Fabricante : Watlow Electric
Arquivo Tamanho: 217.97 kb
Arquivo Nome : 733ase_d.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


BOX 5580, Winona, MN 55987-5580, Phone: 507/454-5300, Fax: 507/452-4507 0600-0008-0000 Rev D $10.00 November 1995 Made in the U.S.A. Supersedes without change: W733-XSMN Rev D00 Contents Contents This manual is a supplement to the Series 733/734 Program Manual. It is for configuring, servicing and calibrating your control. Use this manual in conjunction with the Series 733/734 Program Manual and Data Communications manual. PageItem Chapter 1 3 Install and Wire the Series 733/734 3 Dimensions 3 Panel Cutout 4 How to Wire the Series 733/734 5 Power Wiring 5 Input Wiring 8 Output 1 Wiring 9 Output 2 Wiring 10 Event Input Wiring 10 Event Output Wiring 10 Alarm Wiring 11 System Wiring Examples Chapter 2 12 The Setup Mode 12 Advancing Through the Setup Mode 12 Select or Change Setup Data Within the Mode 13 Setup Parameters 16 Setup ModeTable Notes . Informational notes alert you to important details. When you see a note icon, look for an explanation in the margin. Safety Information Boldface safety information protects both you and your equipment. Please be attentive to them. Here are explanations: c The CAUTION symbol (exclamation point) in the wide text column alerts you to a "CAUTION," a safety or functional hazard which could affect your equipmentor its performance. A full explanation is in the narrow column on the outside of the page. The WARNING symbol (lightning bolt) in the wide text column alerts you to a "WARNING," a safety hazard which could affect you and the equipment. A full explanation is in the narrow column on the outside of the page. Chapter 3 16 The Service Mode 17 Service Parameters 18 Service Mode Table Chapter 4 20 Auto-Tuning 21 Manual Tuning Chapter 5 22 The Calibration Mode 23 Calibration Parameters 24 Calibration Procedures Appendix 30 Glossary 32 Index 33 Warranty/Returns 34 Specifications 35 Ordering Information 36 CE Declaration of Conformity 37 Notes 38 Notes Technical Assistance If you encounter a problem with your Series 733/734 control, review all of your configuration information to verify that your selections are consistent with your application... Inputs, Outputs, Alarms, Limits, etc. If the problem persists after checking the above, you can get technical assistance by dialing: 1-507-454-5300 An Application Engineer will discuss your problem with you. Please have the following information available: • Complete model number • Revision number • All configuration information • User's manual The model and serial numbers can be found on the outside of the case. Your Feedback Your comments or suggestions on the manual are welcome, please send them to: Technical Writer, Watlow Controls, 1241 Bundy Blvd., P.O. Box 5580, Winona, MN 55987-5580, or phone 507/454-5300. The Watlow Series 733/734 Service Manual and integral software are copyrighted by Watlow Winona, Inc., © 1995, with all rights reserved. WATLOW Series 733/734 Service Manual Install & Wire, Chapter 1 Install Install Chapter 1 Install and Wire the Series 733/734 Front panel mounting for ease of installation and service. Figure 1 Series 733 and 734 1.975 SERIES 734 1 10 7 4 2 11 8 5 3 12 9 6 EVENT READY LOAD 1 MENUS WATL W Dimensions. (50 mm) 10.625" (270 mm) SERIES 733 TL WWA 8 10 121 3 52 4 6 7 9 11 EVENT LOAD 1READY MENUS 3.25" (83 mm) 3.25" (83 mm) 10.625" (270 mm) Series 733 Series 734 Panel Cutout . 9.78" (248 mm) 3.13" (80 mm) 0.27" Dia. (7 mm) 2.75" (70 mm) 10.13" (257 mm) R 0.125" (3 mm) Max. Use four #6-32 screws with press-in-nuts (customer supplied) Figure 2 Panel Cutout. . 1. Make a panel cutout per the dimensions given above. NOTE: 2. Drill four 0.265 (7mm) diameter holes per the dimensions given above.. For Series 734 orientation (verti- See Figure 2. cal), rotate the panel cutout 90°. 3. Mount the Series 733 or 734 with four #6-32 screws using press-in-nuts, weld nuts, or equivalent… Install & Wire, Chapter 1 WATLOW Series 733/734 Service Manual Wiring Wiring Figure 6 Series 733/734 Rear View. How to Wire the Series 733/734 The Series 733/734 wiring is illustrated by model number option. Check the terminal designation sticker on the control and compare your model number to those shown here and also the model number breakdown on the inside back cover of this manual. When you apply power without sensor inputs on the terminal strip, the Series 733/734 display alternates parameter data and Er07 at a 3 second rate. This error indicates an open sensor or A/D error. Remove power to the control and connect the sensor properly. All wiring and fusing must conform to the National Electric Code and to any locally applicable codes as well. Use Figure 6 as a location reference when wiring your unit. 9-pin Event Input/ 12-pin Output Output Wiring Connector Connector Input/ Communications Connector WATLOW Series 733/734 Service Manual Install & Wire, Chapter 1 Wiring Wiring Power Wiring 123 456 789 101112 Fuse L2 L1 Input Wiring Use this wiring connector as a reference for terminal orientation. Each individual wiring breakdown...

Este manual também é adequado para os modelos :
Estação Meteorológica - 733 (217.97 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias