Instruções de Operação Watlow Electric, Modelo 602

Fabricante : Watlow Electric
Arquivo Tamanho: 272.02 kb
Arquivo Nome : series_602_eng.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


The control mode is time proportioning with automatic reset. There is a front panel adjustment for the proportional band and internal adjustments for the auto reset on all models and for cycle time on the solid state and relay output models. Access to internal adjustments is available by loosening just one screw and pulling the controller out of the case. Analog meter indication is available in the form of a deviation meter or a direct reading meter. In addition, there are front panel mounted L.E.D.’s to indicate when A.C. power is applied to the controller and when power has been applied to the load. Sensor inputs available are Types “J” and “K" thermocouple. Outputs available are relay, solid state, and process. DATA SHEET 602 SERIES SPECIFICATIONS: CONTROL MODE: Time proportioning with automatic reset. PROPORTIONAL BAND: Front panel adjustment is: 1) (Relay and solid state outputs) 5 to 50°F. 2) (Process outputs) 5 to 100°F. AUTO RESET: Internal adjustment. Adjustable over a range of 0.5 to 0.05 repeats per minute. Can be defeated by adding a jumper wire internally on process units or across terminals 1 and 2 on the barrier strip for the other models. CYCLE RATE: Relay and solid state models only. Internal adjustment. Range of adjustment is 1 to 20 seconds. SENSOR: Thermocouple, Types “J” and “K". OUTPUTS: 1) Relay: S.P.D.T. plug-in. Rated at 10A/120V, 5A/240V resis- tive, 50 V.A. inductive. 2) Solid State: a) Zero .switching isolated triac rated 1 ampere at 120/240V. Note: Load current must be 0.05 amperes to insure proper triac switching. b) Zero switching isolated triac rated 15 amperes at 120/240V. Note: Load current must be 0.1 amperes to insure proper triac switching. 3) Process Outputs: (Current output into 500 ohms load maximum.) a) 0 - 20 mA/0 - 5V. b) 4 - 20 mA/1 - 5V. Note: Terminals 4 and 5 must be jumped if voltage output only is to be used. INDICATION: 1) Direct Reading: An analog meter superimposed over the dial scale that indicates temperature directly. 2) Deviation: A calibrated analog meter integral to the con- troller that uses the set point temperature ± 30°C or ± 50°F to indicate process temperature. INDICATOR LIGHTS: Long life LE.D.’s. 1) Power: Indicates when A.C. power has been applied to the controller. 2) Load: Indicates when power has been applied to the load. LINE VOLTAGE: 115/230 VAC, -10%, +20% 50/60 Hz. POWER CONSUMPTION: Less than 5 V.A. OPERATING AMBIENT: 30 to 130°F. SET POINT SHIFT W/AMBIENT: Typically 10 microvolts/°F referred to the input. SET POINT SHIFT W/LINE VOLTAGE: Typically ± 0.1% of span for ± 10% change in line voltage. ISOLATION: T.C. input to load and line for relay and solid state models. D.C. resistance: 1011 ohms. Capacitance: 50 pf. SENSOR PROTECTION: In the event of an open sensor, Ibad power will be removed. REMOTE CONTROL OR SLAVING: The unit has the capability of being controlled by an external source. There is also the possibility of slaving one controller to another for master control from one location. Consult the factory for further information. oinks, WINONA, MINNESOTA 55987 1265 EAST SANBORN STREET PHONE 507 454-5300 PANEL CUTOUT T/C IN <+) H CIEWUNCÍ NOLI M0U«T WITH IJ.5«* X I2.7M«) «OMC X l/2ifl MN Him SCREWS «NB STP NUT pum » (}.$■■) 6-32NC NUTS WHIN! Of fRONT Of CINTR0ltEt(M,S2a*) SQ. ALTERNATE PANEL CUTOUT T/C SERIES 608 TEMPERATURE CONTROL TERMINAL DESIGNATIONS 2 VOLTAGE (OUT) 4 ~^J-CURRENT (OUT) 5. NOT USED 6. A.C. LINE COMMON. L2 7. 120V LINE. L1 8. 240V LINE. L1 9. T.C. + "| ID. NOT USED SENSOR 11. T.C-. RED J 12. NOT USED 13. SET POINT + (OUT) 14. PROGRAMMER + [IN) 15. SIGNAL COND. + (OUT) 16. CIRCUIT COMMON MODEL:._ RANGE:_ T.C. TYPE:_ WATLOW WINONA WINONA. MINN. T/C IN {+) H PROCESS OUTPUT nT/C SENSOR T/C IN (+)(-) SERIES 602 TEMPERATURE CONTROL TERMINAL DESIGNATIONS 2 -]*UTO. RESET DISABLE 3. T1 “I N.O. SOLID STATE 4. T2_f OUTPUT 5. BATE (FOR EXTERNAL TRIAC) 6. A.C. LINE COMMON, L3 7. 1R0V LINE. L1 B. 240V LINE. L1 0. T.C. + "I 10. NOT USED j-SENSOR 11. T.C-. RED J 12. NOT USED 13. SET POINT + (OUT) 14. PROGRAMMER + (IN) 15. SIGNAL COND. + (OUT) 16. CIRCUIT COMMON MODEL:_ RANGE:_ T.C. TYPE: _ WATLOW WINONA , WINONA. MINN. T/C IN (+> H 5/1/79 SERIES 602 TEMPERATURE CONTROL TERMINAL DESIGNATIONS g t]}AUTa BESET disable A wnT CONTACT RATED 5 c JS30V MAX" 5AMP- R M S'. 6. A.C. LINE COMMON. 12 7. 120V LINE. L1 8. 240V LINE. L1 S. T.C. ♦ 1 1D. NOT USED rSENSDR 11. T.C-. REO J 12. NOT USED 13. SET POINT + (OUT) 14. PROGRAMMER + (IN) 15. SIGNAL COND. + (OUT) 16. CIRCUIT COMMON MDOEL:_ RANGE:_ T.C, TYPE:_ WATLOW WINONA WINONA, MINN. ORDERING INFORMATION INDICATION— 1 - ANALOG (D.R.) 2 - ANALOG (DEV.) É n-m ^ l— RflNßP rnnf OUTPUT MODE- 0 - COOLING 1 - HEATING RANGE CODE - T/C ONLY SEE RANGE CHART 3. OUTPUT B) 10A RELAY C) 1A TRIAC D) 15A TRIAC E) 4-20 mA/l-5V L) 0-20 mA/0-5V NOTE: Consult factory on availabili...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias